• Title/Summary/Keyword: power grid

Search Result 2,993, Processing Time 0.027 seconds

${\mu}$BGA and ${\mu}$Spring Packages for Rambus DRAM Applications and Their Electrical Characteristics (Rambus DRAM실장용 ${mu}!$BGA (Ball Grid Array) 및 ${mu}!$Spring 패키지와 전기적 특성)

  • Kim, Jin-Seong;Yu, Yeong-Gap
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.4
    • /
    • pp.243-250
    • /
    • 2001
  • This paper presents the structure of a $\mu$Spring package, its fabrication process and an analysis of its electrical characteristics compared to that of a $\mu$BGA. It was found that both $\mu$BGA and $\mu$Spring packages provide with outstanding high speed signal transmission characteristics due to their lower inductance of package interconnection lines, smaller than half of inductance of TSOP package lines. Even the worst case substrate trace of a Rambus DRAM $\mu$Spring package yields the line inductance of 2.9nH, which provides with 25% margin compared to the Rambus DRAM specification of 4nH. The fabrication cost of $\mu$Spring package is lower than that of $\mu$BGA by 50%, passes 1000 thermal cycles, meets JEDEC Level 1 specification whereas $\mu$BGA does not, and thereby yields high reliability and strong competing power.

  • PDF

A Comparison of effectiveness of Gracey curet and Mini-five curet on subgingival scaling and root planing (치은연하 치석제거와 치근면 활택술시 Gracey curet과 Mini-five curet의 치석제거 효과에 대한 비교 연구)

  • Jang, Won-Hyeuck;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.585-595
    • /
    • 1997
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, two types of anterior curet were used on ant. teeth to conduct subgingival scaling and root planing. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth extracted from patients being treated at Dan Kook University dept. Perio. were used. 4 surfaces per tooth a total of 96 areas were evaluated. 12 teeth treated with Gracey No. 1-2 was used as the control group and 12 teeth treated with Mini-five curet No. 1-2 was the experimental group. The 4 surfaces of the teeth {buccal, mesial, lingual or palatal, distal) were observed under a stereomicroscope and the images were captured 3 times per surfaced with a CCD. The image were observed on the monitor using a $10{\times]10$ grid produced with the Microsoft power point. The amount of calculus remaining was evaluated 3 times per surface. The results were as follows. 1. There was no significant difference in remaining calculus according to the pre-treatment pocket depth, and tooth position{Mx. or Mn). 2. The Mini-five curet showed better results than the Gracey curet but there was no statistically significant difference. 3. In both Gracey curet group and Mini-five curet group the lingual(or palatal) surface showed significant difference compared to the other surfaces(p<0.05). From the results above, it is thought that when treating ant. teeth consideration of the tooth surface is more important than the choice of instrument.

  • PDF

Effect of Process Variation of Al Grid and ZnO Transparent Electrode on the Performance of Cu(In,Ga)Se2 Solar Cells (Al 그리드와 ZnO 투명전도막 의 공정변화에 따른 Cu(In,Ga)Se2 박막태양전지의 특성 연구)

  • Cho, Bo Hwan;Kim, Seon Cheol;Mun, Sun Hong;Kim, Seung Tae;Ahn, Byung Tae
    • Current Photovoltaic Research
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 2015
  • CIGS solar cell consisted of various films. In this research, we investigated electrode materials in $Cu(In,Ga)Se_2$ (CIGS) cells, including Al-doped ZnO (ZnO:Al), intrinsic ZnO (i-ZnO), and Al films. The sputtered ZnO:Al film with a sputtering power at 200W showed the lowest series resistance and highest cell efficiency. The electrical resistivity of the 200-W sputtered ZnO:Al film was $5.2{\times}10^{-4}{\Omega}{\cdot}cm$ by the rapid thermal annealing at $200^{\circ}C$ for 1 min. The electrical resistivity of i-ZnO was not measurable due to its high resistance. But the optical transmittance was highest with less oxygen supply and high efficiency cell was achieved with $O_2/(Ar+O_2)$ ratio was 1% due to the increase of short-circuit current. No significant change in the cell performance by inserting a Ni layer between Al and ZnO:Al films was observed.

Development of Representative GCMs Selection Technique for Uncertainty in Climate Change Scenario (기후변화 시나리오 자료의 불확실성 고려를 위한 대표 GCM 선정기법 개발)

  • Jung, Imgook;Eum, Hyung-Il;Lee, Eun-Jeong;Park, Jihoon;Cho, Jaepil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.149-162
    • /
    • 2018
  • It is necessary to select the appropriate global climate model (GCM) to take into account the impacts of climate change on integrated water management. The objective of this study was to develop the selection technique of representative GCMs for uncertainty in climate change scenario. The selection technique which set priorities of GCMs consisted of two steps. First step was evaluating original GCMs by comparing with grid-based observational data for the past period. Second step was evaluating whether the statistical downscaled data reflect characteristics for the historical period. Spatial Disaggregation Quantile Delta Mapping (SDQDM), one of the statistical downscaling methods, was used for the downscaled data. The way of evaluating was using explanatory power, the stepwise ratio of the entire GCMs by Expert Team on Climate Change Detection and Indices (ETCCDI) basis. We used 26 GCMs based on CMIP5 data. The Representative Concentration Pathways (RCP) 4.5 and 8.5 scenarios were selected for this study. The period for evaluating reproducibility of historical period was 30 years from 1976 to 2005. Precipitation, maximum temperature, and minimum temperature were used as collected climate variables. As a result, we suggested representative 13 GCMs among 26 GCMs by using the selection technique developed in this research. Furthermore, this result can be utilized as a basic data for integrated water management.

A Study on Security Requirements of Electric Vehicle Charging Infrastructure Using Threat Modeling (위협모델링을 이용한 전기차 충전 인프라의 보안요구사항에 대한 연구)

  • Cha, Ye-Seul;Kim, Seung-joo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1441-1455
    • /
    • 2017
  • In order to build a secure electric vehicle charging infrastructure, security research is required because various data including charging and payment data are transmitted in the electric vehicle charging infrastructure. However, previous researches have focused on smart grid related security research such as power system infrastructure rather than charging infrastructure for electric vehicle charging. In addition, research on charging infrastructure is still lacking, and research using a systematic methodology such as threat modeling is not yet under way. Therefore, it is necessary to apply threat modeling to identify security threats and systematically analyze security requirements to build a secure electric vehicle charging infrastructure. In this paper, we analyze the electric vehicle charging infrastructure by accurately identifying possible threats and deriving objective security requirements using threat modeling including Data Flow Diagram, STRIDE, and Attack Tree.

Development of a Smart meter Applying the ANSI C12.22 International Communication Protocols (ANSI C12.22 국제 통신 프로토콜이 적용된 스마트미터 개발)

  • Lee, Sang-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2952-2959
    • /
    • 2013
  • In this paper, a smart meter applying the international communication protocols has been developed. A smart meter requires communication protocols for two-way communication and control technology, registration and deregistration of electronic devices between electric power suppliers to exchange data. Standardization for communication protocols of a smart meter has been proceeding both in the US and Europe. The smart meter developed in this paper applied ANSI C12.22 as a communication protocol which is a north american standard. A smart meter should also provide the electric consuming information and electricity charge information to the customer in real time. Thus, the customer can behave the demand response based on this information. In this paper, the measured electricity from the smart meter is reported to the customer, and IHD(In Home Display) implemented with the windows software presents the reported real time data.

ESBL: An Energy-Efficient Scheme by Balancing Load in Group Based WSNs

  • Mehmood, Amjad;Nouman, Muhammad;Umar, Muhammad Muneer;Song, Houbing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.4883-4901
    • /
    • 2016
  • Energy efficiency in Wireless Sensor Networks (WSNs) is very appealing research area due to serious constrains on resources like storage, processing, and communication power of the sensor nodes. Due to limited capabilities of sensing nodes, such networks are composed of a large number of nodes. The higher number of nodes increases the overall performance in data collection from environment and transmission of packets among nodes. In such networks the nodes sense data and ultimately forward the information to a Base Station (BS). The main issues in WSNs revolve around energy consumption and delay in relaying of data. A lot of research work has been published in this area of achieving energy efficiency in the network. Various techniques have been proposed to divide such networks; like grid division of network, group based division, clustering, making logical layers of network, variable size clusters or groups and so on. In this paper a new technique of group based WSNs is proposed by using some features from recent published protocols i.e. "Energy-Efficient Multi-level and Distance Aware Clustering (EEMDC)" and "Energy-Efficient Multi-level and Distance Aware Clustering (EEUC)". The proposed work is not only energy-efficient but also minimizes the delay in relaying of data from the sensor nodes to BS. Simulation results show, that it outperforms LEACH protocol by 38%, EEMDC by 10% and EEUC by 13%.

A Study on the Development of Block Type Smart Classroom under the Educational Conditions in Africa (아프리카 지역의 교육 여건에 따른 블록형 스마트 교실 구축방안 연구)

  • Choi, Jong Chon;No, In-Ho;Yoo, Gab-Sang
    • Journal of Digital Convergence
    • /
    • v.17 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • The purpose of this study is to present a block type smart classroom model for comprehensive supply of educational contents, classroom environment and ICT technology in African countries where educational infrastructure is weak. It will provide a contextual solution that integrates learning management, power management, and classroom environment management systems, and will be a convergence model that can optimize economic and non-economic conditions for different African countries. It can be expected to enhance utilization as it is a differentiated model from existing classrooms with a single container, as well as independent research and development centered on services, content, and solutions. Through this integrated research process, we can overcome the spatial and functional limitations appearing in single container classrooms and build a flexible space for advanced e-learning technology. The depth and scope of the follow-up study can be carried by investigating the performance and models that are in line with the educational and infrastructure conditions of the various regions.

A Study on the Design Method of Zero Energy Building considering Energy Demand and Energy Generation by Region (지역별 에너지 소요량과 생산량을 반영한 제로에너지건축물의 설계 방안에 관한 연구)

  • Lee, Soon-Myung;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.13-22
    • /
    • 2018
  • The purpose of this study was to consider the energy generation of the building as well as the energy demand of the building in terms of zero energy building design. The reason why the zero energy building viewpoint should be discussed is that direction of the building, heat transfer rate of the building, and the S/V ratio of the building are variables related to energy demand and solar panels installed on the building roof and building envelope are variables related to energy generation. This study proceeded as follows; Firstly, the simulation model of large office and elementary school has the same mutual volume and total floor area, and the each floor area and number of floors are adjusted so that the S/V ratio is different. To the next, the energy demand and energy generation of the simulation model were derived based on the meteorological data of Seoul, Daejeon, Busan. Finally, energy demand, energy generation, and final energy demand were compared with heat transfer rate, S/V ratio, building type, region, and orientation. The results of this study is that consideration of solar power generation in terms of energy generation should be taken into consideration at the same time in consideration of the heat transfer rate, the shape, the region and the direction of the zero energy building design.

A Study on the Investment Review of Passive and Active Elements through Comparison of Energy Demand and Generation Variation of Zero Energy Building (제로에너지건축물의 에너지 소요량과 생산량 비교를 통한 패시브와 액티브 요소의 투자 검토 연구)

  • Lee, Soon-Myung;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.13-22
    • /
    • 2018
  • At the time when zero energy building is expected to be generalized, this study examines whether the investment in the passive element or the active element is more effective in terms of energy in the construction process of zero energy building. In other words, the effect of energy demand by passive element and the change of energy generation by active element are examined in terms of the same investment cost. The purpose of this study is to examine the change of energy demand by passive element and the change of energy generation by active element in zero energy building and to make reasonable investment decision by comparing energy with cost aspect. For this purpose, we selected the buildings to be subjected to energy simulation and derive the required energy amount and energy generation amount by using meteorological data of four regions in Korea. The change of energy demand and energy generation according to the change of application condition was derived. In order to compare and analyze the changes in energy demand and generation at the same cost standard through price survey and quotation of window and photovoltaic power generation equipment.