• 제목/요약/키워드: power function distribution

검색결과 709건 처리시간 0.024초

Estimation for the Power Function Distribution Based on Type- II Censored Samples

  • Kang, Suk-Bok;Jung, Won-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권4호
    • /
    • pp.1335-1344
    • /
    • 2008
  • The maximum likelihood method does not admit explicit solutions when the sample is multiply censored and progressive censored. So we shall propose some approximate maximum likelihood estimators (AMLEs) of the scale parameter for the power function distribution based on multiply Type-II censored samples and progressive Type-II censored samples when shape parameter is known. We compare the proposed estimators in the sense of the mean squared error (MSE) through Monte Carlo simulation for various censoring schemes.

  • PDF

Notes on Parametric Estimations in a Power Function Distribution

  • Woo, Jungsoo;Yoon, Gi-Ern
    • Communications for Statistical Applications and Methods
    • /
    • 제6권3호
    • /
    • pp.919-928
    • /
    • 1999
  • We shall propose the MME MLE and UMVUE for the mean parameter and the right-tail probability in a power function distribution and obtain the mean squared errors for the proposed estimators. And we shall compare numerically efficiencies of the MME MLE and UMVUE of the mean parameter and the right-tail probability in a power function distribution.

  • PDF

시변 고장률을 이용한 배전계통 유지보수 우선순위 결정 (Deciding the Maintenance Priority of Power Distribution System using Time-varying Failure Rate)

  • 이희태;문종필;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.476-484
    • /
    • 2006
  • The failure prediction and preventive maintenance for the equipment of nuclear power plant area using reliability-centered maintenance have been grown. On the other hand, the maintenance for power distribution system consists of time-based maintenance mainly. In this paper, the new maintenance algorithms for power distribution system are developed considering reliability indices. First of all, Time-varying failure rates are extracted from data accumulated at KEPCO using exponential distribution function and weibull distribution function. Next, based on the extracted failure rate, reliability for real power distribution system is evaluated for applying the effective maintenance algorithm which is the analytic method deciding the maintenance point of time and searching the feeder affecting the specific customer. Also the algorithm deciding the maintenance priority order are presented based on sensitivity analysis and equipment investment plan are analyzed through the presented algorithm at real power distribution system.

Properties of the Poisson-power Function Distribution

  • Kim, Joo-Hwan
    • Communications for Statistical Applications and Methods
    • /
    • 제2권2호
    • /
    • pp.166-175
    • /
    • 1995
  • When a neutral particle beam(NPB) aimed at the object and receive a small number of neutron signals at the detector without any errors, it obeys Poisson law. Under the two assumptions that neutral particle scattering distribution and aiming errors have a circular Gaussian distributions that neutral particle scattering distribution and aiming errors have a circular Gaussian distribution respectively, an exact probability distribution of neutral particles vecomes a Poisson-power function distribution. We study and prove some properties, such as limiting distribution, unimodality, stochastical ordering, computational recursion fornula, of this distribution. We also prove monotone likelihood ratio(MLR) property of this distribution. Its MLR property can be used to find a criteria for the hypothesis testing problem.

  • PDF

태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구 (A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems)

  • 김찬혁;박현석;노대석;신창훈;윤기갑
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

엑티브필터를 사용한 태양광 발전시스템의 출력제어 (Control Method of Output of PV Generation System using Shunt Active Filter)

  • 성낙권;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.225-227
    • /
    • 2002
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

PV-AF 시스템의 개념설계 및 시제작 시스템에 관한 연구 (A Study on the Conceptual Design & Test System of PV-AF System)

  • 박영길;김종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1687-1689
    • /
    • 2005
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

Power Exponential Distributions

  • Zheng, Shimin;Bae, Sejong;Bartolucci, Alfred A.;Singh, Karan P.
    • International Journal of Reliability and Applications
    • /
    • 제4권3호
    • /
    • pp.97-111
    • /
    • 2003
  • By applying Theorem 2.6.4 (Fang and Zhang, 1990, p.66) the dispersion matrix of a multivariate power exponential (MPE) distribution is derived. It is shown that the MPE and the gamma distributions are related and thus the MPE and chi-square distributions are related. By extending Fang and Xu's Theorem (1987) from the normal distribution to the Univariate Power Exponential (UPE) distribution an explicit expression is derived for calculating the probability of an UPE random variable over an interval. A representation of the characteristic function (c.f.) for an UPE distribution is given. Based on the MPE distribution the probability density functions of the generalized non-central chi-square, the generalized non-central t, and the generalized non-central F distributions are derived.

  • PDF

피크전류 제한 기능을 갖는 초전도한류기의 계통 적용에 따른 보호기기간 동작특성 분석 (Analysis on the Operational Characteristic between the Protective devices and Superconducting Fault Current Limiter with a Peak Current Limiting Function in the Power Distribution System)

  • 조용선;김진석;김재철;임성훈
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, the operational characteristics due to the introduction of the superconducting fault current limiter(SFCL) with a peak current limiting function were analyzed in the power distribution system. The parallel structure of the superconducting element can operate the peak current limiting function depending on the transient amplitude of fault current. We studied the operating characteristics of the introduction of the SFCL with a peak current limiting function in the power distribution system. Furthermore, we were analyzed between the SFCL with a peak current limiting function and the protection devices in the power distribution system, through the short circuit experiments.

효율적인 배전관리를 위한 컴퓨터 응용 프로그램 연구 (A Study on Computer Application Program to an Efficient Supervisory Control of the Power Distribution System)

  • 이병철;서영노;이진혁;정진현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.96-98
    • /
    • 1993
  • In accordance with increase of electrical power demanded, more efficient supervisory control of distribution system is required. This study contains development of MMI(man-machine-interface) system with GUI(graphic-user-interface), for the automatic power distribution system. The main function of MMI system are to edit network of power distribution, to view network, to warnning a breakdown and to management of data base for network. The GUI function of MMI system enables more efficient management of power distribution system.

  • PDF