• Title/Summary/Keyword: power conversion equipment

Search Result 105, Processing Time 0.027 seconds

A Study of Wind Energy Conversion System by a Secondary Control Hydrostatic Transmission (2차측 제어 정유압 변속기를 이용한 풍력발전시스템에 관한 연구)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • Wind energy has been more and more important and contributive in the energy utilization of the world. This paper proposed a novel method for Wind Energy Conversion System (WECS), in which a secondary control hydrostatic transmission (SC-HST) with two hydraulic accumulators, were employed for wind energy conversion system. This approach can absorb the excessive power of turbine, keep the generator from over-speed and maintain the speed of generator in low speed of turbine. A PID controller was designed for speed control to track a predefined speed. The simulation results indicated that the speed of the generator was ensured with the relative error less than 2%; and the efficiency of the proposed system was 70.4%.

Process Modeling of the Coal-firing Power Plant as a Testbed for the Improvement of the System and Equipment (화력발전 시스템 및 설비 개선 실증을 위한 열물질정산 공정모델 개발)

  • Ahn, Hyungjun;Choi, Seukcheun;Lee, Youngjae;Kim, Beom Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.23 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Heat and mass balance process modeling has been conducted for a coal-firing power plant to be used as a testbed facility for development of various plant systems and equipment. As the material and design of the boiler tube bundle and fuel conversion to the biomass have become major concerns, the process modeling is required to incorporate those features in its calculation. The simulation cases for two different generation load show the satisfying results compared to the operational data from the actual system. Based on the established process conditions, the hypothetical case using wood pellet has also been simulated. Additional calculations for the tube bundle has been conducted regarding the changes in the tube material and design.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

Transient Stability Analysis of Vessel Power System Using Alternative Marine Power (육상전원공급장치(AMP) 이용한 선내 전원 공급 시 계통 안정도 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.215-222
    • /
    • 2023
  • Alternative marine power (AMP) is continuously used in ports and on docks because of regulations on global ship emission reduction. In Korea, the use of AMP is also mandatory under the Special Act on Port Air Quality Improvement, and efforts are under way in connection with various eco-friendly ships, such as electric-propulsion ships. In this study, AC load flow analysis was performed by modeling the situation in which onboard power is supplied through AMP. This analysis made it possible to study the electrical parameters and losses when power was supplied to the ship. In addition, through a transient stability analysis, the high-speed generation transfer limit value for uninterruptible conversion through onboard generators in the event of a system accident was derived. The results obtained when it was applied are presented

High Efficiency and High Power-Factor Power Supply for LED Lighting Equipment (고효율 고역률 LED 조명장치용 전원공급장치)

  • Jeong, Gang-Youl
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.23-34
    • /
    • 2018
  • This paper presents the high efficiency and high power-factor power supply for LED lighting equipment. The proposed power supply is the single-stage power structure consisted of the full-bridge diode rectifier and flyback converter, and thus the power-factor correction and output voltage regulation are performed simultaneously using only one controller IC and one power semiconductor switch. Furthermore, the proposed power supply reduces the voltage stress and switching loss of main switch using the regenerative snubber, and it improves the system efficiency using the synchronous rectifier. The applied synchronous rectifier is the new voltage-driven type and its operation and construction are simple. In this paper, the operation principle of proposed power supply is explained through the operation analyses of its power-factor correction and main power conversion parts and the operation of synchronous rectifier is described, briefly. Also, a design example of the power circuit of 40W-class prototype is shown and the operation characteristics of proposed power supply are validated through the experimental results of the implemented prototype by the designed circuit parameter.

PWM Converter with Unity Power Factor for UPS systems (고역률 PWM CONVERTER를 적용한 UPS)

  • Lee, Woo-Cheol;Suh, In-Young;Lee, Bum-Hee;Seo, Dong-Hwi;Kueon, Seong-Gon;Kim, Sung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.753-755
    • /
    • 1993
  • Full Bridge Diode Rectification and Phase Controlled SCR Rectification are the most widely used methods of power conversion($AC{\rightarrow}DC$) in Power Electronic products such as UPS systems. But using these types of converters can lead to the following problems. First, they generate harmonics on the AC input side, which can cause interference in other equipment connected to the same commercial power line. Second, they deteriorate the power factor so that the input power capacity or the equipment becomes larger than the actual rated output capacity. As a means to overcome these problems an IGBT type PWM Converter, which applies a current control algorithm, is proposed. In this paper the enhancement of the converter performance is shown through simulation.

  • PDF

Reliability Analysis of the 300 W GaInP/GaAs/Ge Solar Cell Array Using PCM

  • Shin, Goo-Hwan;Kwon, Se-Jin;Lee, Hu-Seung
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.2
    • /
    • pp.69-74
    • /
    • 2019
  • Spacecraft requires sufficient power in orbit to perform its mission. So as to comply with system requirements, the sufficient power should be made by a solar cell array by photovoltaic power conversion. A life time of space program depends on its mission considering parts reliability and parts grade. Based on the mission life time, power equipment might be designed to meet specifications. In outer space, solar cell array might generate the dc power by photovoltaic conversion effects and GaInP/GaAs/Ge solar cells are used in this study. Space programs that require more than five years should select parts for high reliability applications. Therefore, reliability analysis for high reliability applications should be performed to check its fulfilment of the requirements. This program should also require more five years for its mission and we performed its analysis using parts count method (PCM) for its reliability. Finally, we performed reliability analysis and obtained quantitative figures found out 99.9%. In this study, we presented the reliability analysis of the 300 W GaInP/GaAs/Ge solar cell array.

A Development of Efficient Power Conversion Technology for Reduction of Power Equipment (전원설비 저감을 위한 고효율 전력변환기술 개발)

  • Koo, Myoung-Wan;Lee, Woo-Won;Lim, Kye-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.142-144
    • /
    • 2008
  • The Former High Efficiency Inverter(the power restoration process) system process has advantage which is the energy reduction rather than the Former Inverter(the resistence damping process), However, under repair and remodeling, the power facilities capacity is not easy to increase that the former High Efficiency Inverter needs to increase the Power Facilities Capacity of 20~30% than the Inverter(the resistence damping process) so Therefore we are going to suggest the system which is not going to make an increase the power facilities capacity and is applicable the High Efficiency Inverter.

  • PDF

Research and Analysis of Difference Hybrid DC Circuit Breaker Topologies for MVDC Distribution System (MVDC 배전시스템에서 다양한 복합형 직류 차단기의 토폴로지 연구 및 분석)

  • Go, Yu-Ran;Min, Myung-Hwan;An, Tae-Pung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • The importance of DC breakers as key protection equipment is increasing in accordance with growing concerns on MVDC distribution network systems without DC/AC conversion. Different from the situation in AC systems, no natural zero-crossing point exists in DC systems. Thus, DC breaker technology is more difficult than AC breaker technology. The solutions for DC breakers can be divided into three types: mechanical, power electronics, and hybrid. In this study, the operating principles of several topologies of hybrid circuit breakers and that of the proposed DC breaker are analyzed and simulated by sorting two types. The breakers are compared in terms of the type and number of semiconductors, volume, power loss, auxiliary components, isolation, and other aspects. The advantages and disadvantages of the breakers are also analyzed.

Surge Immunity Performance Enhancement Techniques on Battery Management System (전지관리장치(BMS)의 서지내성 성능향상 기법)

  • Kim, Young-Sung;Rim, Seong-Jeong;Seo, Woohyun;Jung, Jeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.