• Title/Summary/Keyword: power controllability

Search Result 118, Processing Time 0.072 seconds

A 0.13 ㎛ CMOS Dual Mode RF Front-end for Active and Passive Antenna (능·수동 듀얼(Dual) 모드 GPS 안테나를 위한 0.13㎛ CMOS 고주파 프론트-엔드(RF Front-end))

  • Jung, Cheun-Sik;Lee, Seung-Min;Kim, Young-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.48-53
    • /
    • 2009
  • The CMOS RF front-end for Global Positioning System(GPS)are implemented in 1P8M CMOS $0.13{\mu}m$ process. The LNAs consist of LNA1 with high gain and low NF, and LNA2 with low gain and high IIP3 for supporting operation with active and passive antenna. the measured performances of both LNAs are 16.4/13.8 dB gain, 1.4/1.68 dB NF, and -8/-4.4 dBm IIP3 with 3.2/2 mA form 1.2 V supply, respectively. The quadrature downconversion mixer is followed by transimpedance amplifier with gain controllability from 27.5 to 41 dB. The front-end performances in LNA1 mode are 39.8 dB conversion gain, 2.2 dB NF, and -33.4 dBm IIP3 with 6.6 mW power consumption.

  • PDF

Development of Usability Evaluation Criteria for Senior-Friendly Autonomous Transportation Robot

  • Kim, Seon Chil;Kim, Sun Jung;Choi, Kyongon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.407-422
    • /
    • 2014
  • Objective: The purpose of the study is to develop quantitative usability evaluation criteria for senior-friendly autonomous transportation robot. Background: The Republic of Korea has become the most rapidly aging society, and is anticipated to enter the post-aged society in 2026. To raise the quality of life of a senior with limited mobility and to reduce the burden of caregivers, many high-tech assistive products with information technologies are developed nowadays. The senior-friendly autonomous transportation robot is one person robot vehicle to move a senior to the destination for hospitals, nursing homes or silver town complex. With built-in navigation system and environmental monitoring censors, it automatically seeks the path to the destination and avoids collision to obstacles and pedestrians on the way. Due to the early stage of the product, few usability studies in this field have been done, mostly on general service robots to assist seniors, power wheelchairs and delivery robots. ISO and KS standards for the service robots are focused on safety. Method: Based on the reference usability index, the early draft of the usability evaluation questionnaires was developed. After small group tests and interviews, the experts modified the initial draft to the Usability Evaluation Criteria for Senior-Friendly Autonomous Transportation Robot (UEC-SFATR). Result: UEC-SFATR consisted of 4 subscales - Safety, Controllability, Efficiency and Satisfaction. All of the 4 subscales of UEC-SFATR were passed the reliability criteria by 4 groups of seniors, divided by gender and familiarity of smart-devices. Conclusion: UEC-SFATR covers wider area of user experiences of the SFATR and is a good measurement tool to help both the users and developers of the robot. Application: This study provides guide to the future product development and product competitiveness evaluation by quantifying user experiences for the SFATR.

The Influence of He flow on the Si etching procedure using chlorine gas

  • Kim, J.W.;Park, J.H.;M.Y. Jung;Kim, D.W.;Park, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.65-65
    • /
    • 1999
  • Dry etching technique provides more easy controllability on the etch profile such as anisotropic etching than wet etching process and the results of lots of researches on the characterization of various plasmas or ion beams for semiconductor etching have been reported. Chlorine-based plasmas or chlorine ion beam have been often used to etch several semiconductor materials, in particular Si-based materials. We have studied the effect of He flow rate on the Si and SiO2 dry etching using chlorine-based plasma. Experiments were performed using reactive ion etching system. RF power was 300W. Cl2 gas flow rate was fixed at 58.6 sccm, and the He flow rate was varied from 0 to 120 sccm. Fig. 1 presents the etch depth of si layer versus the etching time at various He flow rate. In case of low He flow rate, the etch rate was measured to be negligible for both Si and SiO2. As the He flow increases over 30% of the total inlet gas flow, the plasma state becomes stable and the etch rate starts to increase. In high Ge flow rate (over 60%), the relation between the etch depth and the time was observed to be nearly linear. Fig. 2 presents the variation of the etch rate depending on the He flow rate. The etch rate increases linearly with He flow rate. The results of this preliminary study show that Cl2/He mixture plasma is good candidate for the controllable si dry etching.

  • PDF

Improvement of Steady State Response Using PI+Double Integral Controller (비례적분+이중적분 제어기를 이용한 정상상태 응답 개선)

  • Jung, Gyu Hong
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • The performance characteristics of a dynamic control system are evaluated according to the transient and steady-state responses. The transient performance is the controllability of the output for the tracking of the reference or the ability to reduce or reject the effects of unwanted disturbances; alternatively, the steady-state performance is represented by the magnitude of the control error at the steady state. As the effects of the two performances on each other are reciprocal, a controller design that shows a zero steady-state error for the ramp input is uncommon because of the challenge regarding the achievement of an acceptable transient response. This paper proposes a PI+double-integral controller for the elimination of the steady-state error for the ramp input while a sound transient performance is maintained. The control-gain design procedure is described by the second-order response for the step input and the response of the error dynamics for the ramp input. The PI+double-integral controller is designed for the first-order transfer function that is derived from a system identification with the open-loop experiment data of the dc-motor. The simple structure of the proposed controller enables the adoption of a low-end microcontroller for the implementation of a real-time control. The experiment results show that the control performance is as effective as that of the simulation analysis for the operating point of linear system; furthermore, the PI+double-integral controller can be conveniently applied to the control system, which is desirable for the improvement of the steady-state error.

Safety Culture, A New Challenge to Human Factors Engineering for 21st Century

  • Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.473-492
    • /
    • 2016
  • Objective: This paper discusses the recent challenges to human factors engineering due to the safety culture. Background: As incidents occurring in specific fields such as logistics, plant, energy and medical sectors in Korea, as well as in the public sectors including railway, road, aviation and shipping, are recently raised as social issues from the disaster dimension, those incidents are dealt with as man-made disasters in many cases. The trend regarding all accidents as man-made disasters has been expanded in the active perspective that the controllability of all incidents should be ensured in technology development, due to change from a fatal point of view regarding disasters as random occurrence of uncertainties in the past. Method: Man-made disasters are concluded as human errors, and safety culture stands out as a cause of human errors or a new cause item recently. Because safety culture, however, is a very comprehensive term, of which true nature is obscure, although many definitions of safety culture have been presented, the safety culture may make avoid the true nature and responsibility of an incident, or make the main player and subject obscure. Raising safety culture as a cause without presenting a specific countermeasure will be just a wisdom of hindsight. Results and Conclusion: This study reviews the fundamental discussions on "Is safety culture a task of human factors engineering?" and the existing approach carried out from various perspectives in order to seek an effective approach on the new task of safety culture in the human factors engineering field. This study discusses an engineering approach to meet a precondition that safety culture is not just an added factor through a review of the approaches in the proactive fields such as nuclear power and aviation, and the traditional approaches of human factors engineering. Application: This study especially defines the perspective of socio-technological system that has expanded the existing man-machine system, and discusses a systemic approach embracing various interactions, and several overriding tasks.

Design of Optical Receiver Using Independent-Gate-Mode Double-Gate MOSFETs (Independent-Gate-Mode Double-Gate MOSFET을 이용한 Optical Receiver 설계)

  • Kim, Yu-Jin;Jeong, Na-Rae;Park, Sung-Min;Shin, Hyung-Soon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.13-22
    • /
    • 2010
  • Independent-Gate-Mode Double-Gate(IGM-DG) MOSFET overcomes the limitation of bulk-MOSFET's channel controllability and enables to control the front and back-gate voltages independently. Therefore, circuit designs utilizing the IGM-DG MOSFETs provide the advantage of setting 4-terminal freely, hence achieving not only the performance improvement but also the larger scale integration. This paper presents a 15Gb/s optical receiver with a 1.0V power supply voltage, which consists of a transimpedance amplifier (TIA), a feedforward limiting amplifier (LA), and an output buffer. HSPICE simulations were conducted to confirm the circuit performance, and also to verify the circuit stability issues which may occur from the variations of process and supply voltage.

Fabrication of $TiO_{2}$ In-line Reflection Mirror and Its Characteristics for Fiber Optic Fabry-Perot Interferometric Sensor (광섬유 Fabry-Perot 간섭형 센서 제조를 위한 $TiO_{2}$ 반사막의 형성 및 그 특성)

  • Park, Dong-Soo;Kim, Myung-Gyoo;Kim, Chang-Won;Lee, Jung-Hee;Kang, Shin-Won;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.71-79
    • /
    • 1995
  • For the fabrication of high sensitive intrinsic fiber optic Fabry-Perot interferometeric sensor, the deposition conditions of $TiO_{2}$ thin film used to the internal mirrors of the sensor were investigated. The $TiO_{2}$ film deposited by RF magnetron sputter had higher refractive index ($2.36{\sim}2.48$) and better stoiciometry (O/Ti = 2) than that deposited bye-beam evaporator. In the case of forming $TiO_{2}$ internal mirror by using fusion splicing technique, the $TiO_{2}$ reflection mirror deposited by RF magnetron sputter in the condition of 120W RF power showed high. reflectance and excellent controllability of reflection power. The fabricated intrinsic fiber optic Fabry-Perot interferometer with two $TiO_{2}$ internal mirrors deposited under the condition showed very stable fringe patterns. It is, therefore, expected that the interferometer will be applicable to various high precision sensors.

  • PDF

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.