• 제목/요약/키워드: power control (PC)

검색결과 299건 처리시간 0.032초

적응제어방식 성능비교를 위한 실험실용 프로세스의 제작 및 실험 (Manufacture and experiments of thermal process for comparative study of adaptive control)

  • 주성준;공재섭;박용식;김영철;양홍석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.333-338
    • /
    • 1990
  • Most verification of improvements for adaptive control schemes are. dependent on computer simulations, but these computer simulations have much limitation, because (if complex actual conditions of system. This paper is concerned with the constructions of a thermal process system for experiments with various control schemes. This thermal process system is composed of a water tank, PC-XT, AD/DA converters power supply and thermal sensors. We estimate. the algorithms of pole-assignment adaptive control in the manifold disturbances and environments, changing system dynamics. The system equations for thermal press are included.

  • PDF

PC 클러스터링을 이용한 병렬 최적조류계산에 관한 연구 (Parallel Optimal Power Flow Using PC Clustering)

  • 김철홍;문경준;김형수;박준호;김진호;이화석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.190-193
    • /
    • 2004
  • Optimal Power Flow (OPF) is becoming more and more important in the deregulation environment of power pool and there is an urgent need of faster solution technique for on-line application. So this paper presents parallel genetic algorithm-tap search for the solution of the OPF. The control variables modeled unit active power outputs, generator-bus voltage magnitudes and transformer-tap settings. A number of functional operating constraints, such as branch flow limits, load bus boltage magnitude limits and generator reactive capabilities are included as penalties in the fitness function. In parallel GA-TS, GA operators are executed for each process. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper three populations to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the usefulness of the proposed method, developed algorithm has been tested and compared on an IEEE 30-bus system in the reference paper. From the simulation results, we can find that the proposed algorithm is efficient for the OPF.

  • PDF

멀티 플랫폼 기반 온라인 응용의 데이터 제어 기법 (Data Control Methods of Online Application based on Multi-Platform)

  • 김진덕;진교홍
    • 컴퓨터교육학회논문지
    • /
    • 제5권4호
    • /
    • pp.79-89
    • /
    • 2002
  • 기존의 고정 단발기 (PC)에서만 주로 행해지던 각종 다중 사용자 접속 온라인 응용이 최근 PC와 PDA, 휴대폰 등이 공동 작업을 수행하는 멀티 플랫폼 기반 온라인 응용으로 전환되고 있다. 그러나 지금까지 멀티 플랫폼 기반 온라인 응용은 다중 사용자의 공동 데이터의 동시 접근 및 각 클라이언트의 처리 능력과 통신 속도의 비대칭을 고려하지 않아 컨텐츠가 매우 단순한 실정이다. 이 논문에서는 멀티 플랫폼 기반 동시성 제어 기법, 다양한 클라이언트간의 변경 전파 프로토콜, 모바일 클라이언트의 특성을 고려한 객체 관리 기술을 제안하였다. 그리고 멀티 플랫폼 기반 채팅 프로그램을 제작하여 제안한 기법들이 적절히 동작함을 보였다.

  • PDF

전기철도의 DC급전시스템 시뮬레이터 (Simulator for DC Power Supply System in Electric Railway)

  • 정상기;홍재승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.720-726
    • /
    • 2000
  • The advance of traction motor control technology and the complexity of the traction power supply system makes the simulation essential in determining the dimension of the traction power supply system. The conventional method, use of the simplified and/or empirical equations, becomes inadequate in optimization of the design. The simulator presented in this paper is a numerical time based simulator running on a PC. The input to the simulator includes the track data, the train characteristic, network data and operating data. Basically the simulator conducts train running simulation and loadflow study repeatedly. The principle algorithms and its output is discussed in the paper.

  • PDF

AC Motor 제어용 PWM ASIC 설계 및 개발 (PWM ASIC Development for AC Servo and Spindle motor control)

  • 최종률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.605-609
    • /
    • 2000
  • This paper presents a development of the Pulse Width Modulation ASIC for control of the AC servo or spindle motor in machine tools. The ASIC is designed two PWM functions for simultaneous control of a converter and an inverter. Also the device includes additionally two UART functions for interfacing the RS232C with PC or other devices. The device is connected to the microprocessor of Intel or Motorola by bus interface. The required output voltage and frequency for the motor control is programmed to the PWM block and the corresponding switching signals are calculated and generated with regard to the programmed value.

  • PDF

발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토 (A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant)

  • 선현규;홍영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

Development of Hardware-in-the-loop Simulator for Spacecraft Attitude Control using thrusters

  • Koh, Dong-Wook;Park, Sang-Young;Choi, Kyu-Hong
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.35.3-36
    • /
    • 2008
  • The ground-based spacecraft simulator is a useful tool to realize various space missions and satellite formation flying in the future. Also, the spacecraft simulator can be used to develop and verify new control laws required by modern spacecraft applications. In this research, therefore, Hardware-in-the-loop (HIL) simulator which can be demonstrated the experimental validation of the theoretical results is designed and developed. The main components of the HIL simulator which we focused on are the thruster system to attitude control and automatic mass-balancing for elimination of gravity torques. To control the attitude of the spacecraft simulator, 8 thrusters which using the cold gas (N2) are aligned with roll, pitch and yaw axis. Also Linear actuators are applied to the HIL simulator for automatic mass balancing system to compensate for the center of mass offset from the center of rotation. Addition to the thruster control system and Linear actuators, the HIL simulator for spacecraft attitude control includes an embedded computer (Onboard PC) for simulator system control, Host PC for simulator health monitoring, command and post analysis, wireless adapter for wireless network, rate gyro sensor to measure 3-axis attitude of the simulator, inclinometer to measure horizontality and battery sets to independently supply power only for the simulator. Finally, we present some experimental results from the application of the controller on the spacecraft simulator.

  • PDF

소형 발전기의 에너지 절약을 위한 전력관리 시스템 개발 (Development of Power Management System for Efficient Energy Usage of Small Generator)

  • 전민호;오창헌
    • 한국정보통신학회논문지
    • /
    • 제16권12호
    • /
    • pp.2601-2606
    • /
    • 2012
  • 본 논문에서는 2대 이상의 소형 발전기를 사용하는 환경에서 부하의 전력 소비량을 이용하여 에너지를 절약하는 전력 관리 시스템을 제안하고 개발하였다. 고속의 하드웨어 플로팅 포인트 연산처리가 가능한 TI사의 TMS320C6713 DSP 칩을 사용하여 하드웨어를 구성하였으며, 시리얼 통신을 이용하여 모니터링 PC와 통신하게 하였다. 모니터링 PC에서 수동제어가 가능하도록 하였으며, DSP main board에서 CT/PT센서로 수집한 데이터를 이용하여 자동적으로 발전기를 on/off 할 수 있도록 구현하였다. 실험 결과 본 논문에서 제안한 전력 관리 시스템이 이상 없이 동작하는 것을 확인할 수 있었으며, 부하의 전력사용량을 이용하여 에너지를 절약하는 알고리즘을 적용하였을 경우 소형 발전기 2대를 지속적으로 사용할 때 보다 더욱 오래 전력을 공급하는 것을 알 수 있었다.

저전력 임베디드 보드 환경에서의 딥 러닝 기반 성별인식 시스템 구현 (Gender Classification System Based on Deep Learning in Low Power Embedded Board)

  • 정현욱;김대회;;노용만
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제6권1호
    • /
    • pp.37-44
    • /
    • 2017
  • 사물 인터넷(IoT) 산업이 확산되면서 사용자의 정보를 특별한 조작 없이 물체가 스스로 인식하는 일이 매우 중요해졌다. 그중에서도 성별(남, 여)은 생물학적인 구조가 달라 성향이 다르고 사회적으로도 기대하는 바가 다르기 때문에 매우 중요한 요소이다. 하지만 얼굴 이미지를 기반으로 한 성별 인식과 관련된 연구는 동일한 성별이라도 다양한 생김새를 가지고 있어서 여전히 도전적인 분야이다. 그리고 성별인식 시스템을 사물 인터넷에 적용하기 위해서는 디바이스 크기를 소형화 시켜야 하며 저전력으로 구동이 가능해야 한다. 따라서 본 논문에서는 저전력으로 실제 사물에서 성별을 인식할 수 있는 기능을 탑재하기 위해 딥 러닝 기반의 성별 인식 알고리즘을 제안하고 이를 모바일 GPU 임베디드 보드에 포팅하여 최종적으로 실시간 성별인식 시스템을 구현하였다. 실험에서는 소비전력과 초당 처리 가능한 프레임 수를 PC환경과 모바일 GPU 임베디드 환경에서 측정하여 저전력 환경에서도 성별 인식이 가능함을 증명하였다.

항로표지 충·방전조절기의 제어에 관한 연구 (Studies on the Control of AtoN Charge and Discharge Controller)

  • 예성현;한순희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.654-657
    • /
    • 2014
  • 본 논문에서는 항로표지 충 방전조절기의 근거리 제어방법을 제안하였다. 제안하는 제어방법은 국내에서 운용되는 충 방전조절기의 제어기능을 분석하여 항로표지시설의 통신규격인 NEMA018을 적용하여 구성하였다. 제안된 제어방법을 이용하면 제품분해 없이 방수성을 유지하면서 유 무선통신으로 제어가 가능한 장점이 있다. 또한 운용중인 충 방전조절기의 접근성을 확보할 수 있어 유지보수에 효과적이다. 본 논문에서는 스마트폰에 충 방전조절기 제어를 위한 응용프로그램을 설치하고 블루투스 통신과 PC를 이용하여 제어정보의 유효성을 검토한다. 향후 제안하는 충 방전조절기의 제어방법은 국내 표준으로 제안할 수 있다.

  • PDF