• Title/Summary/Keyword: power absorption

Search Result 849, Processing Time 0.026 seconds

Matching-type Power Dividing Switch for Low Reflection in Indoor Microwave Power Distribution (실내 마이크로파 배전용 완전 정합형 전력 분배 스위치의 설계)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.792-797
    • /
    • 2013
  • In a indoor microwave power distribution system, matching-type power dividing switch is proposed and designed with a various power dividing ratio. A matching coaxial cable probe is used behind the output probe for the reflecting power absorption. Reflecting characteristics of the matching coaxial cable probe are calculated by analyzing the S-parameter of this structure. Newly proposed matching-type switch shows a very low return loss less than -30dB at the operating frequency of 2.45GHz with a dividing power ratio of 50.2%. The simulated results by use of 3-stage power divider shows a good agreement with the theoretical estimation for the various combination of the different switching ratio.

Terahertz Characteristics of D2O and H2O Mixtures (테라헤르츠 분광학을 이용한 중수(D2O)와 경수(H2O) 혼합물의 특성연구)

  • Chong, Joong-Gun;Son, Joo-Hiuk
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.435-438
    • /
    • 2008
  • D2O, which is used in nuclear power generation, is slightly different from $H_2O$. $D_2O$ consists of deuterium (D), which is an isotope of hydrogen (H) and has one more neutron than H. $D_2O$ is heavier by about 11% than $H_2O$, and $D_2O$ is present in water in natureat about 0.002%. Its melting point and boiling point are $3.81^{\circ}C$ and $101.42^{\circ}C$, respectively. $D_2O$ is harmful to the human body if it replaces water in the human body by more than $25%{\sim}50%$. We have measured the index of refractive and power absorption of 0%, 25%, 50%, 75%, and 100% of $D_2O$ in $H_2O$ using terahertz time-domain spectroscopy, and we have found that the refractive index decreases and power absorption also decreases as the concentration of $D_2O$ increases.

Computational Fluid Dynamic Modeling for Internal Antenna Type Inductively Coupled Plasma Systems (CFD를 이용한 내장형 안테나 유도 결합 플라즈마 시스템 모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.164-175
    • /
    • 2009
  • CFD is used to analyze gas flow characteristics, power absorption, electron temperature, electron density and chemical species profile of an internal antenna type inductively coupled plasma system. An optimized grid generation technology is used for a complex real-scale models for industry. A bare metal antenna shows concentrated power absorption around rf a feeding line. Skin depth of power absorption for a system is modeled to 50 mm, which is reported 53 mm by experiments. For an application of bipolar plates for hydrogen fuel cells, multi-sheet loading ICP nitriding system is proposed using an internal ICP antenna. It shows higher atomic nitrogen density than reported simple pulsed dc nitriding systems. Minimum gap between sheets for uniform nitriding is modeled to be 39 mm.

A Study on the Fire Properties of MOF Insulation Cover and Field Condition of 22.9kV Class Power Receiving System (22.9kV 수변전설비의 실태 및 계기용변성기 절연커버의 출화특성에 관한 연구)

  • Choi Chung-Seog;Kim Dong-Woo;Han Woon-Ki;Lee Ki-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.56-60
    • /
    • 2005
  • We studied fire properties of MOF(Metering Out Fit) insulation cover and field condition of 22.9kV power receiving system. $49.5\%$ of formal equipments were installed indoors, whereas $40.8\%$ of informal equipments were installed as H-type. Insulation treatment was not done at a $22.4\%$ ratio of main line($27.7\%$ of transformer, $70.2\%$ of COS, $10.4\%$ of MOF). Fire pattern analysis showed that the fire started at the secondary part of OC wire. In the result of DTA(Differential Thermal Analysis), normal cover showed exothermic reactions at $310^{\circ}C,\;399^{\circ}C\;and\;510^{\circ}C$ (endothermic reactions at $382^{\circ}C$). Whereas damaged cover showed exothermic reactions at $412^{\circ}C$(endothermic reactions at $389^{\circ}C$). In the result of TGA(Thermo Gravimetric Analysis), the thermal weight change of normal cover was similar compared to damaged cover. In the result of FT-IR analysis, normal cover showed absorption peaks at $3,024cm^{-l},\;2,921cm^{-l},\;1,600cm^{-1},\;1,492cm^{-1},\;1,451cm^{-1},\;1,154cm^{-l},\;1,027cm^{-1},\;906cm^{-1}$. Whereas, in case of tracked cover, the absorption peaks that were shown in normal cover disappeared and different absorption peak was shown at $966cm^{-1}$.

Fundamental Studies of Gas-jet Assisted Radio Frequency Glow Discharge Atomic Absorption Spectrometry (원자흡수법에 의한 Gas-Jet Assisted RF 글로우방전 시스템의 특성 연구)

  • Choi, Seong-Kyu;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-77
    • /
    • 1995
  • The instrumentation and operating characteristics of a gas-jet assisted radio frequency glow discharge atomic absorption spectrometry(RF-GDAAS) are studied. The roles of discharge power, pressure as well as gas flow rate on the sample loss rate and absorbance are described in this paper. Results show that the optimum discharge conditions depend on pressure and discharge power as well as on the gas flow rate. The gas flow rate plays as an important parameter in RF-GDAAS. Absorbance increases as the gas flow rate increase up to 600ml/min., and the optimum absorbance is obtained at the pressure of 3 mbar. The absorbance increases when the discharge power increases as expected, however, the instability of the system due to the heat might be the trade off factor. The linear calibration curves of Ni and Cr in stainless steel(BAS 461-468) and brass (KSS 1121-1126) are obtained with RF-GDAAS.

  • PDF

Comparative Study on Evaluation of Inelastic Energy Absorption Capacity for Seismic Fragility Analysis of Structures (구조물의 지진취약도분석을 위한 비탄성에너지흡수능력의 평가 기법에 관한 비교 연구)

  • 조양희;조성국;박형기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.135-142
    • /
    • 2002
  • This paper introduces the technologies related to seismic resistance assessment of nuclear power plant structures by seismic fragility analysis(SFA). The inelastic energy absorption factor is considered in SFA to represent the effects due to the nonlinear behavior of structures and has a significant effect on the seismic fragility that is a probability of failure of structures by earthquake. Several practical methods to evaluate the inelastic energy absorption capacity of structures are investigated. The capacities determined by those methods are compared with each other. And an improved method that uses the inelastic demand capacity diagram is presented. Conclusively, some comments on each method for practical application are made.

  • PDF

Oxide Glasses for Holographic Data Storage

  • Poirier, Gael;Nalin, Marcelo;Ribeiro, Sidney J.L;Messaddeq, Younes
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.86-90
    • /
    • 2007
  • Novel photochromic oxide glasses are presented in this section. These glasses are based on phosphate formers containing both tungsten and antimony atoms. Exposure to visible continuous or pulsed laser beam results in an intense photochromic effect witch is shown to occur in the volume of the glass and results in a broad absorption band in the visible and near infrared. This effect was not identified to be related with a structural change and is assumed to be entirely electronic. A change in the absorption coefficient is observed in function of tungsten content, exposure time and increases with beam power. These glasses have been investigated regarding the possibility of holographic data storage using visible lasers sources. Changes in both refractive index and the absorption coefficient were measured using a holographic setup. The modulation of the optical constants is reversible by heat treatment.

  • PDF

Children's Mobile Phone Use and Dosimetry

  • Lee, Ae-Kyoung;Kwon, Jong-Hwa
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.167-172
    • /
    • 2015
  • Research results on possible effects caused by radiofrequency fields in children are limited because most of the studies published so far have focused on adults, rather than children. Mobile phone use is now widespread, even among younger children. If a biological risk due to mobile phone exposure is found, it might be greater in children because their bodies might be more sensitive to radiofrequency energy. The issue of a possible difference in sensitivity between adults and children begins with whether any difference exists physically in terms of electromagnetic absorption. This paper presents a review of recent publications on dosimetric comparisons between children and adults with respect to radiation from mobile phones. The issue of the health effects of mobile phone use is beyond the scope of the present review. Most of the dosimetry research on possible differences in power absorption between children and adults has been based on numerical modeling and analysis. The understanding of the results so far is presented and needed studies are described.

A Study on Sound Absorption Properties of Foamed Concrete with Continuous Voids (연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구)

  • 이승한;박정준;황보광수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.567-570
    • /
    • 2000
  • This study is designed to manufacture the continuous foamed concrete and the sound absorption characteristics investigation due to continuous voids ratio. According to the results of experiment, it was shown that continuous voids of the foamed concrete has the influence of the amount used of foaming agent, the viscosity and flowability of cement paste, and also is shaped by cohesive power of bubbles. Also the sound absorption ratio of the foamed concrete is subject to increase as the density becomes low by raising the continuous voids ratio. The cement paste with low water-cement ratio and high cement fineness are very effective to prevent weak strength of formed concrete caused by the increase of the porosity.

  • PDF

The Verification on Effect of Sound Absorption Tunnel for Elevated Railway (고가철교 방음터널 효과검증)

  • Kim, Hyung-Doo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.122-127
    • /
    • 2008
  • The source of wayside noise for the train are the aerodynamic noise, wheel/rail noise, and power unit noise. The major source of railway noise is the wheel/rail noise caused by the interaction between the wheels and rails. The Structure borne noise is mainly a low frequency problem. The train noise and vibration nearby the elevated railway make one specific issue. The microphone array method is used to search sound radiation characteristics of elevated structure to predict the noise propagation from an elevated railway. In this paper, the train noise and structure borne noise by train are measured. From the results, we investigated the effect on the sound absorption tunnel for elevated railway.