• Title/Summary/Keyword: potentiodynamic

Search Result 369, Processing Time 0.031 seconds

Effects of Alloying Elements and Binding Materials on the Corrosion Behavior of Metal Hydride Electrodes (금속수소화물전극의 부식특성에 미치는 합금원소와 결합제의 영향)

  • Lee, Yang-Boum;Choe, Han-Cheol;Park, Ji-Yoon;Kim, Kwan-Hyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.4
    • /
    • pp.161-167
    • /
    • 1998
  • It has been investigated the effects of alloying elements and binders on the corrosion behavior of metal hydride electrodes for anode of Ni/MH secondary battery. The $AB_5$-type alloys, $(LM)Ni_{4.49}Co_{0.1}Mn_{0.205}Al_{0.205}$ and $(LM)Ni_{3.6}Co_{0.7}Mn_{0.3}Al_{0.4}$, were used for the experiments. The electrodes were prepared by mixing and cold-pressing of alloy powders with Si sealent or PTFE powders, or cold-pressing the electroless copper coated alloy powders. The amount of copper coating was 20wt%. In order to examine corrosion behavior of the electrodes, the corrosion current and the current density, in 6M KOH aqueous solution after removal of oxygen in the solution, were measured by potentiodynamic and cyclic voltamo methods. The results showed that Co in the alloy increased corrosion resistance of the electrode whereas Ni decreased the stability of the electrode during the charge-discharge cycles. The electrode used Si sealant as a binder showed a lower corrosion current density than the electrode used PTFE and the electrode used Cu-coated alloy powders showed the best corrosion resistance.

  • PDF

Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials (TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성)

  • Kim, Y.U.;Cho, J.Y.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

Electrode characteristics of $AB_2$ type hydrogen storage alloy modified by Cr, La addition and fluorination ($AB_2$계 수소저장합금의 전극특성에 미치는 Cr, La 첨가 효과 및 표면 불화처리 효과)

  • Chang I.;Lee B. H.;Cho W. I.;Jang H.;Cho B. W.;Yun K. S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • [ $AB_2-type$ ] alloy, one kind of hydrogen storage alloys used as an anode of Ni-MH batteries, has large discharge capacity but has remaining problems regarding initial activation, cycle life and self-discharge. This study investigates the effects of Cr-addition and fluorination after La-addition on $Zr_{0.7}Ti_{0.3}V_{0.4}Mn_{0.4}Ni_{1.2}$, composition $AB_2-type$ alloy. EPMA and SEM surface analysis techniques were used and the crystal structure was characterized by XRD analysis. In addition, electrodes were fabricated out of the alloys and characterized by constant current cycling test, electrochemical impedance spectroscopy and potentiodynamic polarization. Cr-addition was found to be effective to cycle life and self-discharge but ineffective to initial activation due to formation of stable oxide film on surface. Fluorination after La-addition to the alloys improved initial activation remarkably due to formation of highly reactive particles on surface.

The Effect of Additives on the Properties of Zn Electrode in Zn/AgO Secondary Battery (Zn/AgO Secondary Battery용 아연 양극의 성능에 미치는 첨가제의 영향)

  • Park, Kyung-Wha;Kim, Chang-Hwan;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • We investigated the effect of both 4 types additives and $0.5wt\%\;Pb_3O_4$ which have been reported to show an improvement on the performance of Zinc anode. And Experimental methods such as corrosion potential measurement, potentiodynamic polorization test and charging-discharging cycle life test were carried out in $40 wt\%$ KOH with $Pb_3O_4(0.5, \;10\;&\;2.0wt\%)$ and 4 types additives $(0.4wt\%\;of\;Ca(OH)_2$, 0.025M of Citrate, Tartrate and Gluconate). Corrosion potential was shifted to high direction and also changed to high and low direction repeatedly with increasing of $Pb_3O_4$ quantity. However by adding $0.5wt\%\;Pb_3O_4$, corrosion potential shifted to low direction and showed stable condition. Furthermore it was well known that corrosion resistance was predominantly increased compared to no addition and improved charging-discharging property with adding additives. By SEM analysis, it was concluded that the morphology of surface in case of only $0.5wt\%\;Pb_3O_4$ addition was nearly the same as that of Tartrate additive and in the other additives such as $Ca(OH)_2$, Citrate, Tartrate and Gluconate, their morphologies showed dendrite growth. Eventually it was thought that the additive of Tartrate indicated comparatively good corrosion resistance effect as well as charging-discharging property improvement among those four types additives.

A STUDY OF ION BEAM ASSISTED DEPOSITION(IBAD) OF TiN ON Ni-Cr Be ALLOY FOR SURFACE CHARACTERISTIC (이온빔 보조 증착법에 의한 TiN 박막도포가 니켈-크롬-베릴륨 합금의 표면 성상에 미치는 영향에 관한 연구)

  • Choi, Soo-Young;Lee, Sun-Hyung;Chang, Ik-Tae;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.212-234
    • /
    • 1999
  • Dental restorative materials must have the physical properties to withstand wear and corrosion. Base metal alloys possess better mechanical properties and lower price than the gold alloys. For these reasons such alloys have largely replaced the precious metal alloys. One aspect to con-sider is the release of metal substances to oral environment. The release of elements from dental alloys is a continuing concern because the elements may have the potentially harmful biological effects on local tissues. The purpose of this study was to minimize metal release on the nonprecious metal surfaces by ion beam assisted deposition(IBAD) of titanium nitride (TiN) Ni-Cr-Be alloys with and without TiN coatings were secured in an wear test machine opposing ruby ball to determine their relative resistance to wear with loom, 200m, 300m and 400m sliding distance. And the corrosion behavior of the Ni-Cr-Be alloys with and without TiN coatings and 3 dental noble alloys have been studied. Potentiodynamic curves were used to analyse the corrosion characteristics of the alloys. The measurement of the released Ni and Cr ions was conducted by analysis of the electrolyte solution with atomic absorption spectroscopy. The results were as follows : 1. The critical sliding distance that wore down TiN coatings of $2.5{\mu}m$ thickness in this study condition was 300m. 2. Ion beam assisted deposition of TiN showed a good surface modification with respect to the properties of wear and corrosion resistance. 3. X-ray diffraction showed that the strongest peak of TiN is TiN(111) in the coatings. 4. The release of Ni and Cr ions from alloys measured by means of atomic absorption spectroscopy was reduced by ion beam assisted deposition of TiN.

  • PDF

Effect of Additional Elements on Efficiency of Al and Zn Sacrificial Anode for Naval Vessels (함정용 Al 및 Zn 희생양극의 효율에 미치는 첨가원소 영향)

  • Choi, Woo-Suk;Park, Kyung-Chul;Kim, Byeong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.277-283
    • /
    • 2015
  • MS(Mild Steel), HTS(High Tensile Steel), HYS(High Yield Steel), AL(Aluminum Alloy) and Composite Materials are used for vessels. Steel Materials are mostly used for vessels because body of a ship have to perform the basic functions such as watertight, preserving the strength and supporting the equipments. The vessels primarily carry out a mission at ocean, so that body of a ship is necessarily rusted. There are several methods to protect the corrosion of vessels such as painting, SACP(sacrificial anode cathodic protection) and ICCP(impressed current cathodic protection). For the sacrificial anode cathodic protection, Al and Zn alloys are normally used. Heavy metals are added to the Al and Zn Alloys for improving the corrosion properties but they are so harmful to the human and environment. Therefore, the use of these heavy metals is strictly regulated in the world. In this paper, Al and Zn Alloys are made by adding the trace elements(Ma, Ca, Ce and Sn) which is not harmful to the human and environment. SEM, XRD, Potentiodynamic Polarization test and Current Efficiency test are conducted for evaluation of Al and Zn Alloys. As a result of the experiment, Al-3Zn-0.6Sn and Zn-3Sn Alloys are more efficient than other Alloys.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

Corrosion Behaviors of TiN Coated Dental Casting Alloys (TiN피막 코팅된 치과주조용 합금의 부식거동)

  • Jo, Ho-Hyeong;Park, Geun-Hyeng;Kim, Won-Gi;Choe, Han-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.129-137
    • /
    • 2009
  • Corrosion behaviors of TiN coated dental casting alloys have been researched by using various electrochemical methods. Three casting alloys (Alloy 1: 63Co-27Cr-5.5Mo, Alloy 2: 63Ni-16Cr-5Mo, Alloy 3: 63Co-30Cr-5Mo) were prepared for fabricating partial denture frameworks with various casting methods; centrifugal casting(CF), high frequency induction casting(HFI) and vacuum pressure casting(VP). The specimens were coated with TiN film by RF-magnetron sputtering method. The corrosion behaviors were investigated using potentiostat (EG&G Co, 263A. USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion morphologies were analyzed using FE-SEM and EDX. Alloy 1 and Alloy 2 showed the ${\alpha}-Co$ and ${\varepsilon}-Co$ phase on the matrix, and it was disappeared in case of TiN coated Alloy 1 and 2. In the Alloy 3, $Ni_2Cr$ second phases were appeared at matrix. Corrosion potentials of TiN coated alloy were higher than that of non-coated alloy, but current density at passive region of TiN coated alloy was lower than that of non-coated alloy. Pitting corrosion resistances were increased in the order of centrifugal casting, high frequency induction casting and vacuum pressure casting method from cyclic potentiodynamic polarization test.

Oxide Films Formed on Hot-Dip Aluminized Steel by Plasma Electrolytic Oxidation and Their Films Growth Stages (플라즈마 전해 산화법에 의해 용융알루미늄도금 강판 상 형성한 산화층과 그 성장 과정)

  • Choe, In-Hye;Kim, Chang-Min;Park, Jun-Mu;Park, Jae-Hyeok;Hwang, Seong-Hwa;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.165-165
    • /
    • 2017
  • 지난 수 십 년 동안, 전 세계적으로 자원의 소비가 급격히 증가하게 되면서 최근 자원 고갈은 물론 환경오염이 커다란 이슈로 문제가 되고 있다. 이에 따라 재료 관련 분야에 있어서는 보다 효율적이고 친환경적인 방법으로 자원을 활용해야 된다는 필요성이 대두되었고 이와 같은 관점에서 목적하는 성분이 우수하고 환경 친화적인 표면처리 재료 개발연구가 활발하게 진행되고 있는 실정이다. 그 중 플라즈마 전해 산화(Plasma Electrolytic Oxidation, PEO)는 알루미늄, 마그네슘 등의 경금속의 경도를 향상시키고 높은 내마모성, 내식성을 갖게 하는 표면처리로써 그 관심이 증가하고 있다. 이 플라즈마 전해 산화는 일반적으로 공정비용 대비 효과적이고 환경 친화적이며 코팅 성능 면에서 우수하다고 알려져 있다. 이러한 고유한 특성으로 인해 플라즈마 전해 산화 코팅은 최근 몇 년 동안 기계, 자동차, 우주항공, 의학 및 전기 산업 등의 분야에서 그 적용이 점차 증가하고 있는 상황이다. 한편, 플라즈마 전해 산화 코팅을 하는 모재들의 경우 부동태 산화피막을 용이하게 형성할 수 있는 특성의 모재에 한정되고 있어서 그 응용확대에 한계가 있는 것이 사실이다. 따라서 본 연구에서는 플라즈마 전해 산화법을 사용하여 용융알루미늄도금 강판 상에 산화피막 형성을 시도하였다. 전원공급 장치의 양극은 전해질 속에 잠겨있는 작동전극에 연결하고 음극은 대전극 역할을 하는 스테인레스강 전해질 용기에 연결되었다. 전해질은 Sodium Aluminate 및 기타 첨가제를 함유한 것을 사용하였고 온도는 열교환기를 사용하여 $30^{\circ}C$ 이하로 유지되었다. 또한 여기서 전류밀도는 $5{\sim}10A/dm^2$, 실험 주파수는 700Hz, Duty cycle은 30 및 90%의 각 조건에서 공정처리 시간을 각각 30분 및 60분 동안 진행하였다. 이와 같은 조건에서 형성한 막들에 대해서는 주사형전자현미경(SEM)을 이용하여 코팅 막의 표면 및 단면의 모폴로지를 관찰하였음은 물론 EDS 및 XRD 측정을 통하여 원소조성분포 및 결정구조를 각각 분석하였다. 또한 이 코팅 막들에 대한 내식성은 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 침지 시험 및 전기화학적 동전위 양극분극(Potentiodynamic Polarization) 시험을 진행하여 평가하였다. 이상의 실험결과에 의하면, 제작조건별 플라즈마 전해 산화 코팅 막의 모폴로지 및 결정구조가 상이하게 나타나는 것을 알 수 있었다. 코팅 막의 모폴로지 관찰 결과, 공정 시간에 비례하여 표면에 존재하는 원형 기공의 수는 감소하였으나 그 크기가 커지고 크레이터의 직경 또한 커진 것이 확인되었다. 이 기공은 마이크로 방전에 의해 형성된다고 알려져 있는데 공정 시간이 증가함에 따라 코팅 두께가 점차 증가하여 마이크로 방전의 빈도수가 줄어들고 그 강도는 증가하게 되어 기공 크기가 증가한 것으로 사료된다. 또한 공정시간이 긴 시편에서 표면에 크랙이 다수 존재하는 것으로 확인되었다. 이것은 방전에 의해 고온이 된 소재가 차가운 전해질과 만나게 되어 생긴 큰 온도구배로 인해 강한 열응력이 발생하여 균열을 초래한 것으로 보인다. 조성원소 분석 결과 원형 기공 주변의 크레이터 영역에는 알루미늄이 풍부하였으며 그 주변에 결절상을 갖는 구조에서는 전해질 성분의 원소가 포함되어 있는 것이 확인되었다. 이러한 코팅 막의 표면 특성은 내식성에 영향을 주게 된 원인으로 사료된다. 동전위 분극측정 결과에 의하면 플라즈마 전해 산화 공정 시간이 길어질수록 부식전류밀도가 증가하였다. 이것은 공정시간이 길어짐에 따라 강한 방전이 발생하여 기공의 크기가 증가하고 크랙이 발생하게 되면서 내식성이 저하된 것으로 판단된다. 종합적으로 재료특성 분석 및 내식성 평가를 분석한 결과, 플라즈마 전해 산화의 공정 시간이 너무 길게 되면 오히려 내식성은 저하되는 것이 확인되었다. 이상의 연구를 통하여 고내식 특성을 갖는 플라즈마 전해 산화 막의 유효성을 확인하였으며 용융알루미늄강판 상에 실시한 플라즈마 전해 산화 처리에 대한 기초적인 응용 지침을 제시할 수 있을 것으로 사료된다.

  • PDF