• Title/Summary/Keyword: postural tremor

Search Result 29, Processing Time 0.028 seconds

Effect of tool weight and hand posture on the postural tremor of the upper extremity

  • Kim, Jae Young;Song, Ho Young;Yun, Myung Hwan;Yun, Myun W
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.177-184
    • /
    • 1996
  • In light-weight hand tools, static posture may result in postural fatigue. Psotural tremor of the upper extremity in a static posture was measured to provide guidelines for hand tool weight. Postural tremor was measured on five levels of tool weitht : no weight, 400g, 800g, 1200g, and 1600g. Three types of camcorder recording postures were selected. For each condition, postural tremor was measured together with ENG of biceps, deltoid and pectoralis major, and Borg's CR-20 ratings of perceved exertion. Results of the experiment are as follows : frequency analysis of tremor revealed increased amplitude of frequency bands of 2-4Hz and 10-14Hz. Postural tremor of the upper extremeity maintained the initial level until fatigue developed. After the development of fatigue, the rate of change of postural tremor significantly increased. Different tool weights and hand postures showed different rates of tremor increase. Time tp fatigue and corresaponding endurance time were positively correlated with Borg's RPE scores.

  • PDF

정적자세 유지시 수공구의 무게가 상완의 postural tremor에 미치는 영향에 관한 연구

  • 송호영;김재영;조창규;윤명환;이면우
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.151-157
    • /
    • 1996
  • Postural tremor of the upper arm in a static posture was measured to provide guidelines of hand tool weight. Three types of camera recording postures were selected. Postural tremor was measured on five levels of tool weights; no weight, 400g, 800, 1200g, and 1600g. For each conditions, upper arm postural tremor was measured together with EMG of biceps, deltoid, and pectoralis major, and Borg's CR-20 scale ratings of perceived exertion. Results of the experiment are as follows; Frequency analysis of tremor revealed that increased amplitude of frequency band of 2-4Hz and 10-14Hz was observed. Postural tremor of the upper arm maintained the initial level until fatigue developed. After the development of fatigue, the rate of the change of postural tremor was significantly increased. Different tool weights and hand postures showed different rate of tremor increase. And time to fatigue and the corresponding endurance time was positively correlated with Borg's RPF scores.

  • PDF

Effects of Task and Part on Tremor Characteristics in Patients with Essential Tremor (본태성 진전 환자의 진전특성에 대한 수행과제 및 부위의 영향)

  • Heo, J.H.;Kim, J.W.;Kwon, Y.R.;Eom, Gwang-Moon;Kwon, D.Y.;Lee, C.N.;Park, K.W.;Manto, M.
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Essential tremor is a neurological disorder with a tremor of the arms and hands. It is well known that essential tremor is characterized by the postural tremor and the action tremor. There has been no report on the quantitative difference in the characteristics of two tremor types. The purpose of this study was to investigate the possible difference in tremor characteristics of postural and action tremors. Seventeen patients with essential tremor ($68.9{\pm}7.9years$, 7 men, 10 women) participated in this study. Patients performed the tasks of postural maintenance (arms outstretched) and daily actions (spiral drawing). Three-axes (pitch, roll and yaw) gyro sensors were attached on index finger, back of hand and forearm, from which the segment and the joint angular velocities were calculated. Outcome measure was the tremor amplitude defined as the root-mean-square mean of the vector-sum angular velocity at segments and joints. Two-way ANOVA showed that task and joint had main factor on the tremor amplitude (p < 0.05). Post-hoc analysis revealed that tremor amplitude at the metacarpo-phalangeal joint was not affected by task (p > 0.05). However, tremor amplitude at the wrist joint differed among the tasks (p < 0.05), and it was greater in the action tasks than in postural task. Tremor was greater at finger segments than at hand and forearm and it increased in action tasks. The results of this study would be helpful for the understanding and task-specific treatments of the essential tremor.

Discrimination of Parkinson's Disease from Essential Tremor using Acceleration based Tremor Analysis (가속도계를 이용한 진전현상의 분석을 통한 파킨슨병과 본태성 진전의 판별)

  • Lee, Hongji;Lee, Woongwoo;Jeon, Hyoseon;Kim, Sangkyong;Kim, Hanbyul;Jeon, Beom S.;Park, Kwangsuk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.103-108
    • /
    • 2015
  • Discrimination of Parkinson's disease (PD) from Essential tremor (ET) is often misdiagnosed in clinical practice. Since tremor is time-varying signal, and dominant and harmonic frequencies are shown in tremor only with moderate or severe symptom, there are some limitations to use frequency related features. Moreover, patients with PD or ET can suffer from both resting tremor and postural tremor. In this study, 28 patients with PD and 17 patients with ET were enrolled. Tremor was measured with accelerations on the more affected hand during resting and postural conditions. The ratio of root mean square (RMS) of resting tremor to RMS of postural tremor, the mean coefficients of autocorrelation function (ACF), and the mean of differences of two adjacent coefficients of ACF at resting and postural were calculated and compared between PD and ET. The performance showed 98% accuracy with support vector machine and leave-one-out cross validation. In addition, the method accurately differentiated the patients with tremor-dominant PD from patients with ET, with 100% accuracy. Therefore, the developed algorithm can assist clinicians in diagnosing and categorizing patients with tremor, especially, patients with mild symptom or the early stage of a disease, for proper treatment.

Analysis of Gait Parameters According to the Clinical Features of Parkinson's Disease Using 3-D Motion Analysis System with Electrogoniometer (3차원 전기측각 보행분석기를 이용한 파킨슨씨병 환자의 임상 양상에 따른 보행 분석)

  • Baek, Hye-Jin;Yoon, Joon-Shik;Kim, Sei-Joo;Lee, Gyu-Ho;Koh, Seong-Beom
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Background: To investigate the differences of locomotor dynamics between Parkinson's disease (PD) patients with tremor dominant symptom and patients with postural instability dominant symptom. Methods: 66 subjects with PD were classified into two subgroups, tremor-dominant group and postural instability and gait disorder group by Unified Parkinson's disease rating scale (UPDRS). The spatial, temporal and electrodynamic gait parameters were recorded automatically using computerized 3-D motion analysis system with electrogoniometer. Results: There was no significant difference in cadence, pelvic tilt range, hip flexion range, knee flexion range and ankle dorsiflexion range. Postural instability and gait disorder group showed decreased gait velocity, short stride length, decreased range of motion in pelvic obliquity, pelvic rotation and ankle plantar flexion. Conclusions: There was meaningful difference in locomotor dynamics between Parkinson's disease(PD) patients with tremor dominant symptom and patients with postural instability dominant symptom.

  • PDF

Quantitative Assessment of Tremor in PD Using a Wearable System on Both Hands (양손에서 웨어러블 시스템을 이용한 파킨슨병의 정량적 진전 평가)

  • Lee, Hongji;Kim, Sangkyong;Kim, Hanbyul;Jeon, Hyoseon;Park, Hyeyoung;Jung, Yujin;Kim, Jeonghwan;Jeon, Beomseok;Park, Kwangsuk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.81-86
    • /
    • 2014
  • One of the methods for Parkinson's disease(PD) tremor evaluation is the Clinical Tremor Rating Scale(CTRS). However, the method has some limitations that clinician ratings can vary because the scores are subjectively rated. In addition, most researches usually collected data measured on the more affected arm. In this study, we developed a portable wearable system(SNUMAP system) for measuring PD tremor. The SNUMAP system captures 3-dimensional motion using tri-accelerometer and tri-gyroscope on finger and wrist. 40 PD patients participated in resting tremor and postural tremor tasks, while wearing the system on both hands simultaneously. Estimated tremor scores from Leave-One-Out Cross Validation for regression were highly correlated to the average clinician CTRS scores for rest tremor($r^2$ = 0.87, RMSE = 0.48) and postural tremor($r^2$ = 0.82, RMSE = 0.48). Therefore, the quantitative assessment model can improve treatment of PD patients.

A Clinical Report of Patient with Tremor diagnosed as Ganhyeolbujok(肝血不足) (간혈부족(肝血不足)으로 변증한 진전(振顫)환자 치험(治驗) 1례(例))

  • Kim, Tae-Yong;Park, Jun-Beom;Oh, Min-Kyu;Shin, Hyeon-Su
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.776-783
    • /
    • 2006
  • Tremor is a rhythmic and involuntary muscular contraction characterized by oscillations of a part of the body. The most common of all involuntary movements, tremor can affect various body parts such as hands, head, facial structures, vocal cords, trunk, and legs; most tremors, however, occur in the hands. Clinically, tremor is classified into postural tremor, resting tremor, action tremor, and other kinds of tremor, and treated according to the causes. The author reports the improvement of the patient, hospitalized at Dong Seo Medical Center, whose tremor was not classified specifically in western medicine but was diagnosed as Ganhyeolbujok (肝血不足) by Korean medicine.

  • PDF

Development of a Shooting Training System using an Accelerometer (가속도 센서를 이용한 사격 훈련 시스템 개발)

  • Joo, Hyo-Sung;Woo, Min-Jung;Woo, Ji-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.263-271
    • /
    • 2021
  • Optoelectronic shooting training systems are used in shooting training sites to improve the accuracy of shooting by tracking the trajectories of gun movements. However, optoelectronic-based systems have limitations in terms of cost, complexity of installation, and the risk that electronic targets may be broken. In this study, we developed and verified a shooting training system that measures postural tremors using a low-cost accelerometer. The acceleration sensor module was designed to be attached to the air cylinder of a gun. Postural tremors were evaluated based on amplitude, frequency, and spatial pattern index, which were computed using acceleration data. The postural tremor indices between the accelerometer and optoelectronic-based system were highly correlated (left-right and up-down directions: r = 0.76 and r = 0.70, respectively). We validated the developed shooting training system using an independent two-sample t-test, which identified a significant difference (p < 0.05) in the calculated postural tremor index according to the athlete's shooting score (i.e., best and worst shots).

A Case Report of a Tremor Patient with Stenosis of the Left Carotid Artery (머리 떨림 환자에 대한 한방 치험 1례)

  • Park, Seo-hee
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.6
    • /
    • pp.1096-1100
    • /
    • 2017
  • The carotid artery is one of the main vessels supplying blood to the brain. Carotid artery stenosis is mostly caused by atherosclerosis, a disease where cholesterol is deposited in the arterial blood vessels. Tremor refers to rhythmic shaking of a body part. Tremor is a symptom of many diseases, including Parkinson's disease, essential tremor, orthostatic tremor, cerebellar disease, peripheral neuropathy, and alcohol withdrawal. Tremors may be classified as postural, rest, and action tremors. Tremor of a patient with stenosis of the left carotid artery decreased with acupuncture treatment. The acupoints were GB20, TE17, GV8 and GV11. This case shows that the acupuncture treatment is effective against tremor.