정적자세 유지시 수공구의 무게가 상완의 postural tremor에 미치는 영향에 관한 연구

  • 송호영 (삼성데이타 시스템) ;
  • 김재영 (서울대학교 산업공학과) ;
  • 조창규 (서울대학교 산업공학과) ;
  • 윤명환 (포항공과대학교 산업공학과) ;
  • 이면우 (서울대학교 산업공학과)
  • Published : 1996.04.01

Abstract

Postural tremor of the upper arm in a static posture was measured to provide guidelines of hand tool weight. Three types of camera recording postures were selected. Postural tremor was measured on five levels of tool weights; no weight, 400g, 800, 1200g, and 1600g. For each conditions, upper arm postural tremor was measured together with EMG of biceps, deltoid, and pectoralis major, and Borg's CR-20 scale ratings of perceived exertion. Results of the experiment are as follows; Frequency analysis of tremor revealed that increased amplitude of frequency band of 2-4Hz and 10-14Hz was observed. Postural tremor of the upper arm maintained the initial level until fatigue developed. After the development of fatigue, the rate of the change of postural tremor was significantly increased. Different tool weights and hand postures showed different rate of tremor increase. And time to fatigue and the corresponding endurance time was positively correlated with Borg's RPF scores.

Keywords