• 제목/요약/키워드: posterior single implant

검색결과 66건 처리시간 0.032초

A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas

  • Kim, Sang-Yun;Ku, Jeong-Kui;Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.191-196
    • /
    • 2018
  • PURPOSE. The goal of this study was to evaluate the clinical outcome of single short implants, less than 8 mm in length, placed in the posterior area. MATERIALS AND METHODS. A total of 128 patients (75 male and 53 female, mean age: $52.6{\pm}11.2years$) with 154 implants participated. Implant marginal bone loss, and survival and success rates were measured. RESULTS. The mean follow-up period was $51.35{\pm}24.97months$. A total of 128 implants, 8 mm in length, were placed in patients who had mean marginal bone loss of 0.75 mm. These implants had a survival rate of 95.3%. Twenty-six implants, 7 mm in length, were placed in areas with a mean marginal bone loss of 0.78 mm and had a survival rate of 96.2%. Both marginal bone loss and survival rate were not statistically different among the groups. In the maxilla, 34 implants showed a mean marginal bone loss of 0.77 mm and a survival rate of 97.1%. In the mandible, 120 implants showed a mean marginal bone loss of 0.75 mm and a survival rate of 95.0%. The average marginal bone loss around all implants was $0.76{\pm}0.27mm$ at the last follow-up review after functional loading. The survival rate was 95.6% and success rate was 93.5%. CONCLUSION. In our study, single short implants less than 8 mm in length in the posterior areas had favorable clinical outcomes.

Localization of mandibular canal and assessment of the remaining alveolar bone in posterior segment of the mandible with single missing tooth using cone-beam computed tomography: a cross sectional comparative study

  • Alrahaimi, Saif Fahad;Venkatesh, Elluru
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.100-105
    • /
    • 2017
  • Objectives: Localization of the mandibular canal (MC) and measurement of the height and width of the available alveolar bone at the proposed implant site in the posterior segment of the mandible using cone-beam computed tomography (CBCT) in patients with a single missing tooth. Materials and Methods: A cross-sectional study was performed where CBCT scans of the patients with a single missing tooth in the posterior segment of the mandible-premolar, I (1st) molar, and II (2nd) molar were used. The scans were assessed using OnDemand3D software (version 1.0; CyberMed Inc., Seoul, Korea) for localization of the MC asnd remaining alveolar bone both vertically (from the superior position of the MC to the crest of the alveolar ridge) and horizontally (buccolingual, 3 mm below the crest of the alveolar ridge). The findings were statistically analyzed using independent t-test. Results: A total of 120 mandibular sites (40 sites for each of the three missing premolar, I molar, and II molar) from 91 CBCT scans were analyzed. The average heights (from the alveolar crest to the superior margin of the MC) at the premolar, I molar, and II molar areas were $15.19{\pm}2.12mm$, $14.53{\pm}2.34mm$, and $14.21{\pm}2.23mm$, respectively. The average widths, measured 3 mm below the crest of the alveolar ridge, at the premolar, I molar, and II molar areas were $6.22{\pm}1.96mm$, $6.51{\pm}1.75mm$, and $7.60{\pm}2.08mm$, respectively. There was no statistically significant difference between males and females regarding the vertical and horizontal measurements of the alveolar ridges. Conclusion: In the study, the measurements were averaged separately for each of the single missing teeth (premolar, I molar, or II molar), giving more accurate information for dental implant placement.

Factors affecting maxillary sinus pneumatization following posterior maxillary tooth extraction

  • Lim, Hyun-Chang;Kim, Sangyup;Kim, Do-Hyup;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제51권4호
    • /
    • pp.285-295
    • /
    • 2021
  • Purpose: The aims of the present study were 1) to quantitatively evaluate the extent of sinus pneumatization and 2) to determine the factors affecting sinus pneumatization. Methods: Based on implant treatment records, a list of patients who underwent implant placement on the posterior maxilla was obtained. Among them, patients with pre-extraction and post-extraction (before implant placement) panoramic radiographs were selected. After excluding radiographs with low resolution and image distortion, the radiographs before and after extraction were superimposed using computer software. Subsequently, the extent of sinus pneumatization (the vertical change of the sinus floor) was measured. Simple and multiple mixed models were used to determine the factors affecting sinus pneumatization. Results: A total of 145 patients were eligible for the present investigation. The average extent of sinus pneumatization was 1.56±3.93 mm at 176 tooth sites. Male sex, single tooth extraction, extraction of an endodontically compromised tooth, a class I root-sinus relationship, and sinus membrane thickening >10 mm favored pneumatization, but without statistical significance. The maxillary second molar presented the greatest pneumatization (2.25±4.39 mm) compared with other tooth types. This finding was confirmed in the multiple mixed model, which demonstrated a statistically significant impact of the extraction of a second molar compared with the extraction of a first premolar. Conclusions: Maxillary sinus pneumatization was 1.56±3.93 mm on average. The extraction of a second molar led to the greatest extent of pneumatization, which should be considered in the treatment plan for this tooth site.

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

하악 구치부에서 ITI SLA (Sand-blasted, Large-grit, Acid-etched) 임플란트를 이용한 단일 치아 수복의 후향적 임상 연구 (Retrospective study on ITI SLA (sand-blasted, large-grit, acid-etched) implant for mandibular posterior single tooth replacement)

  • 이승문;채경준;정의원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.661-671
    • /
    • 2006
  • The purpose of this study was to evaluate cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with ITI SLA (sand-blasted, large-grit, acid-etched) implant system and compare the CSR between first and second molar. The findings from the results were as follows; 1. Total of 158 implants were inserted into 147 patients. 68 patients were males, 79 patients were females and their mean age was 47.8 years. 98 implants were placed in first molar area and 60 implants were placed in second molar area. In terms of diameter, implants with wide diameter over 4.8mm dominated (91.1%). Implants with length over lOmm were used (96.2%). 2, In the two cases, there was a slight transient numbness which recovered within 1-2 months. Nine SynOcta screw type abutments demonstrated screw loosening, There were ten cases of crown fallen-out from decementation. 3. Only one failed out of 158 implants. The CSR was 99.4%. The CSRs for first molar and second molar were 99% and 100%, respectively. From the results, it was concluded that single tooth replacement implant in the mandibular posterior area, might be considered as the effective treatment modality comparable to the conventional crown and bridge.

The plaque-removing efficacy of a single-tufted brush on the lingual and buccal surfaces of the molars

  • Lee, Dong-Won;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • 제41권3호
    • /
    • pp.131-134
    • /
    • 2011
  • Purpose: To test the plaque-removal efficacy of a single-tufted toothbrush on the posterior molars compared with a flat-trimmed toothbrush. Methods: Forty-nine subjects were selected. Professional instruction and written brushing instructions were given. After thorough supra-gingival scaling and polishing, all subjects were asked to abstain from oral hygiene procedures for 24 hours prior to the first experiment. The subjects were randomized to a treatment sequence. The modified Quigley and Hein plaque index was recorded pre- and post-tooth brushing, at 6 surfaces of the posterior molars. After a wash-out period, all the remaining plaque was removed professionally. Twenty-four hours of brushing abstinence was again performed. The plaque index was recorded pre- and post-tooth brushing after the subjects were given the second toothbrush in the cross-over sequence. Results: The percentage reductions in plaque scores achieved with the single-tufted brushes were significantly higher than those of the flat-trimmed brush at the maxillary buccal interproximal, marginal and mandibular lingual interproximal site. The other locations showed no significant difference. Conclusions: The results of the present study implied that the single-tufted brush could be an effective tool for the removal of plaque at some, but not all, sites of the posterior molars.

All-ceramic versus titanium-based implant supported restorations: Preliminary 12-months results from a randomized controlled trial

  • Weigl, Paul;Trimpou, Georgia;Grizas, Eleftherios;Hess, Pablo;Nentwig, Georg-Hubertus;Lauer, Hans-Christoph;Lorenz, Jonas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.48-54
    • /
    • 2019
  • PURPOSE. The aim of the present randomized controlled study was to compare prefabricated all-ceramic, anatomically shaped healing abutments followed by all-ceramic abutments and all-ceramic crowns and prefabricated standard-shaped (round-diameter) titanium healing abutments followed by final titanium abutments restored with porcelain-fused-to-metal (PFM) implant crowns in the premolar and molar regions. MATERIALS AND METHODS. Forty-two patients received single implants restored either by all-ceramic restorations (test group, healing abutment, final abutment, and crown all made of zirconia) or conventional titanium-based restorations. Immediately after prosthetic incorporation and after 12 months of loading, implant survival, technical complications, bone loss, sulcus fluid flow rate (SFFR) as well as plaque index (PI) and implant stability (Periotest) were analyzed clinically and radiologically. RESULTS. After 12 months of loading, an implant and prosthetic survival rate of 100% was observed. Minor prosthetic complications such as chipping of ceramic veneering occurred in both groups. No statistical significant differences were observed between both groups with only a minimum of bone loss, SFFR, and PI. CONCLUSION. All-ceramic implant prostheses including a prefabricated anatomically shaped healing abutment achieved comparable results to titanium-based restorations in the posterior region. However, observational results indicate a benefit as shaping the peri-implant soft-tissue with successive provisional devices and subsequent compression of the soft tissue can be avoided.

하악 제1, 2대구치 단일 임플란트의 생존율에 관한 연구 (The study on success rate of single implant replacing the mandibular first and second molars)

  • 정택균;팽준영;조진현;이상한
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.252-260
    • /
    • 2013
  • 연구 목적: 치과 임플란트가 소개된 이후로 단일 치아 상실에 따른 임플란트 수복에 관한 성공적인 연구 결과들이 보고되고 임상적으로도 널리 사용되고 있다. 구강내의 다양한 부위에 따른 연구들이 있어 왔으나, 교합력이 강한 구치부 특히 하악 구치부에서 단일 임플란트에 관한 연구가 필요할 것이다. 본 연구는 하악의 제1대구치와 제2대 구치 부위에 식립된 단일 임플란트의 생존율에 관해 연구, 분석하였다. 연구 대상 및 방법: 2002년부터 2009년까지 대구광역시 소재의 7개 치과의원에서, 하악 제1, 2대구치에 단일 임플란트 치료를 받은 환자 284명에게 식립된 308개의 임플란트를 대상으로 하였다. 하악 제1대구치에 168개의 임플란트가 식립되었고, 하악 제2대구치에 140개의 임플란트가 식립되었다. 이들 임플란트는 식립위치, 환자의 성별, 연령, 임플란트의 직경 및 길이에 따라 분석하였다. 결과:하악 제1대구치에서는 4개의 임플란트가, 하악 제2대구치에서는 10개의 임플란트가 실패하였다. 하악 제1대구치에서는 97.6%, 하악 제2대구치에서는 92.9%의 성공률을 나타내었다. 환자의 연령, 성별, 식립방법, 임플란트의 직경 등에 따른 차이는 관찰할 수 없었다. 결론: 하악 제1대구치 단일 임플란트의 생존율은 하악 제2대구치 단일 임플란트의 생존율보다 높게 나타났다. 이는 하악 제2대구치 부위의 골질이 좋지 않고, 하악의 해부학적인 구조로 인해 하악 제2대구치 부위에 과도한 교합력이 가해질 우려가 있기 때문이라 생각된다.

Association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars: a long-term follow-up clinical and radiographic analysis

  • Lee, Jae-Hong;Kweon, Helen Hye-In;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.396-404
    • /
    • 2016
  • Purpose: The aim of this retrospective study was to determine the association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars, using data collected during from 2002 to 2015. Methods: Traumatic occlusion in the adjacent premolars was assessed by examining clinical parameters (bleeding on probing, probing pocket depth, fremitus, and tooth mobility) and radiographic parameters (loss of supporting bone and widening of the periodontal ligament space) over a mean follow-up of 5 years. Clinical factors (gender, age, implant type, maxillary or mandibular position, opposing teeth, and duration of functional loading) were evaluated statistically in order to characterize the relationship between implants in the posterior region and traumatic occlusion in the adjacent premolars. Results: The study inclusion criteria were met by 283 patients, who had received 347 implants in the posterior region. The incidence of traumatic occlusion in the adjacent premolars was significantly higher for splinted implants (P=0.004), implants in the maxillary region (P<0.001), and when implants were present in the opposing teeth (P<0.001). The other clinical factors of gender, age, and duration of functional loading were not significantly associated with traumatic occlusion. Conclusions: This study found that the risk of traumatic occlusion in the adjacent premolars increased when splinted implants were placed in the maxillary molar region and when the teeth opposing an implant also contained implants.

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.