• 제목/요약/키워드: post-tensioning

검색결과 164건 처리시간 0.022초

PSC 부재의 성능개선기법에 관한 정적 실험 연구 - 유리섬유 부착 공법과 외부 후긴장 보강 공법 - (A Study on Strengthening of PSC Beam by Static Experiment - Glass fiber sheeting and External post-tensioning methods -)

  • 김현호;송재필;김기봉;정영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.157-163
    • /
    • 2003
  • Recently, the number of Prestressed Concrete(PSC) bridges needed repair and retrofit because of the increase of heavy traffic loads and aging of concrete materials. But there are a few related researches about strengthening PSC bridges. In this study, the practicability of strengthening methods for PSC beam were studied by the static experimental method. PSC beams in length of 6m were made with concrete slabs. Glass fiber sheeting and external post-tensioning methods were used for strengthening PSC beams. Some beams were strengthened after cracks to investigate the applicability for cracked bridges. As a result, there strengthening methods were efficient at increasing the cracking loads and the failure load, to decrease deflection and prevent cracks. In the case of using glass fiber retrofit methods, it should be careful in the anchorage problems for preventing the bonding failure.

피로 실험에 의한 PSC 부재의 성능개선기법에 관한 연구 (A Study on Strengthening of PSC Beam by Fatigue Experiment)

  • 김현호;송재필;김기봉;정영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.165-172
    • /
    • 2003
  • The fatigue problem of Prestressed Concrete(PSC) bridges are more serious than the other type of concrete bridges, because the cross sectional area and self weight of PSC bridges are smaller. The endurance of strengthening methods for PSC bridges are tested in this study. Glass fiber sheeting and external post-tensioning methods were applied. 1/5 scale PSC beams were made for fatigue test, same as static test. The range of repeated load is from 10% to 80% of yielding load with sine curve. The experimental results show that the failure cycle of strengthened members are increased compare to non-strengthened members. The members strengthened with glass fiber show better enhancement in fatigue problem than the members strengthened with external post-tensioning method, though the adhesion of glass fiber and concrete is failed, as increase of crack. With these experimental results, it can be said that the strengthening methods used in this study are efficient at extending the life time of aged PSC bridges.

포스트 텐션 플랫 플레이트 외부 접합부의 이력 거동 (Cycle Behavior of Exterior Joint of Flat Plate Slab and Column)

  • 조종;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.239-242
    • /
    • 2005
  • The purpose of this research was focused on substantiating an effects of tendon-layouts and compressed stress($=f_{pc}$) induced by post-tensioning on seismic performance of post-tensioned flat plate slab-column connection designed as non-participating system. To accomplish this purpose, an experimental research of flat plate exterior slab-column connections subjected to gravity load and reversed lateral displacement history are presented. As a result, tendon-layout is a main variable to influence failure mechanism, dissipated energy and lateral deformation capacity. Furthermore, compressed stress ($=f_{pc}$) induced by post-tensioning enhanced the seismic performance of flat plate slab.

  • PDF

Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections

  • Cheng, Chin-Tung
    • Computers and Concrete
    • /
    • 제5권6호
    • /
    • pp.525-544
    • /
    • 2008
  • In this research, the self-centering effect in precast and prestressed reinforced concrete structures was investigated experimentally. The reinforced concrete beams and columns were precast and connected by post-tensioning tendons passing through the center of the beams as well as the panel zone of the connections. Three beam-to-interior-column connections were constructed to investigate parameters such as beam to column interfaces (steel on steel or plastic on plastic), energy dissipating devices (unbonded buckling restrained steel bars or steel angles) and the spacing of hoops in the panel zone. In addition to the self-centering effect, the shear strength in the panel zone of interior column connections was experimentally and theoretically evaluated, since the panel zone designed by current code provisions may not be conservative enough to resist the panel shear increased by the post-tensioning force.

포스트텐션 전이슬래브의 구조해석 및 설계방법 (Structural Analysis and Design of Post-Tension Transfer Slab)

  • 윤장근;강수민;김욱종;이도범;추문석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.19-20
    • /
    • 2010
  • 본 연구는 전이슬래브의 두께를 줄이고 철근량을 감소시키기 위해 포스트텐션을 전이슬래브에 적용하는 포스트텐션 전이슬래브에 관한 연구이다. 본 논문에서는 전이슬래브와 같이 두꺼운 판요소 해석에 적합한 Wood-Armer 공식과 부착 긴장재를 사용한 포스트텐션 설계방법을 제안하고자 한다.

  • PDF

RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템 (Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.147-154
    • /
    • 2008
  • 본 연구에서는 외부 비부착형 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양 및 정착장치의 형상을 변수로 총 10개로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 스터드형 정착장치를 적용한 실험체들의 보강성능은 매립형 정착장치를 적용한 실험체와 동등한 보강성능을 나타내었다.

부분 긴장과 해제를 이용한 연속화 과정에서의 긴장력 조절 (Control of Prestressing Forces in a Splicing Method using the Partial Post-tensioning and Releasing Procedure)

  • 이환우;김광양
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.251-259
    • /
    • 2002
  • 부재의 일정구간에 설치된 긴장재의 긴장작업과 이미 긴장되어 있는 상태의 긴장재를 이완시키므로써 의도적으로 유도되는 2차 모멘트를 이용한 새로운 연속화 공법이 개발되었다. 본 공법에서는 이들 긴장재의 긴장과 이완공정이 가장 핵심이 되는 작업이 되며, 실용적인 측면에서는 그 크기와 순서를 결정하는 것이 주된 과제가 될 것이다. 본 논문에서는 이 과정에서 필요한 최적의 긴장과 이완 비율의 조절 과정에 관하여 연구하였다. 그 결과, 긴장작업과 이완작업은 먼저 긴장작업부터 시작하여 3단계에 걸쳐 점진적으로 실시하는 것이 구조의 안전과 시공성을 위해 타당한 방법으로 나타났다. 그리고, 민감도 분석을 통하여 결정되는 선행 긴장작업의 긴장력 크기는 최소와 최대의 비율범위를 동시에 만족하는 값으로 결정되어야 하나, 시공의 효율성을 위해서 필요할 패는 최소 긴장비율만을 하한치로 하여 결정하여도 큰 문제는 없다.