• 제목/요약/키워드: post tensioned beam

검색결과 50건 처리시간 0.021초

샌드위치 플레이트 시스템을 이용한 합성보의 동적 특성 (Dynamic Characteristic of Composite Beam using the Sandwich Plate System)

  • 류재호;주영규;윤성원
    • 한국공간구조학회논문집
    • /
    • 제14권4호
    • /
    • pp.65-72
    • /
    • 2014
  • To improve the noise and vibration problems of the existing public parking systems, new floor system was proposed. This system consists of the Sandwich Plate System(SPS), steel beam and post-tensioned steel tendons. To verify the dynamic characteristics such as the natural frequency and damping ratio of the system, the free vibration test was performed. Test results showed that the natural frequency of the SPS composite beam was 23.8Hz and it was increased by 3.8% by installing the post-tensioned tendons. The damping ratio of the specimen with tendons was about 1.64%.

사전균열이 발생한 철근콘크리트 보의 외적 포스트텐셔닝 전단보강에서 보강깊이의 효과 (Strengthening Depth Effect in Externally Post-tensioning Shear Strengthening of Pre-cracked Reinforced Concrete Beam)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.19-26
    • /
    • 2018
  • This paper presents the shear strengthening effect of externally post-tensioning (EPT) method using high-strength steel rod in pre-cracked reinforced concrete (RC) beams. Three- and four-point bending tests were performed on a total of 8 specimens by adjusting the strengthening depths in the deviator position of EPT. The effective strengthening depths were 435, 535, and 610 mm. The pre-loading up to about 2/3 of ultimate load capacity measured in unstrengthened RC beam were applied in the beam to be post-tensioned. The EPT method was then applied to the pre-damaged RC beams and re-loading was added until the end of the test. EPT restored deflections of 3 mm or more, which account for about 40% of deflection when the pre-loading was applied. The shear strengthening increases more than 3 times and 36~107% in terms of the stiffness and load-carrying capacity compared to unstrengthening RC beams. The increased load-carrying capacities of the post-tensioned beam with strengthening depths of 435 and 535 mm are almost the same as 36~61%, and those of 610 mm are 84~107%, which shows the greatest shear strengthening effect.

Flexural tests on two-span unbonded post-tensioned lightweight concrete beams

  • Yang, Keun-Hyeok;Lee, Kyung-Ho;Yoon, Hyun-Sub
    • Structural Engineering and Mechanics
    • /
    • 제72권5호
    • /
    • pp.631-642
    • /
    • 2019
  • The objective of the present study is to examine the flexural behavior of two-span post-tensioned lightweight aggregate concrete (LWAC) beams using unbonded tendons and the reliability of the design provisions of ACI 318-14 for such beams. The parameters investigated were the effective prestress and loading type, including the symmetrical top one-point, two third-point, and analogous uniform loading systems. The unbonded prestressing three-wire strands were arranged with a harped profile of variable eccentricity. The total length of the beam, measured between both strand anchorages, was 11000 mm. The test results were compared with those compiled from simply supported LWAC one-way members, wherever possible. The ultimate load capacity of the present beam specimens was evaluated by the collapse mechanism of the plasticity theorem and the nominal section moment strength calculated following the provision of the ACI 318-14. The test results showed that the two-span post-tensioned LWAC beams had lower stress increase (Δfps) in the unbonded tendons than the simply supported LWAC beams with a similar reinforcement index. The effect of the loading type on Δfps and displacement ductility was less significant for two-span beams than for the comparable simply supported beams. The design equations for Δfps and Δfps proposed by ACI 318-14 and Harajli are conservative for the present two-span post-tensioned LWAC beams, although the safety decreases for the two-span beam, compared to the ratios between experiments and predictions obtained from simply supported beams.

특별직교이방성 복합적층판 이론을 응용한 포스트텐션된 슬래브 교량의 해석 (Analysis of Post-tensioned Slab Bridge by Means of Specially Orthotropic Laminates Theory)

  • 한봉구;김은표
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.105-111
    • /
    • 2002
  • 포스트텐션된 슬래브 교량은 특별직교이방성 복합적층판 이론으로 해석할 수 있다. 슬래브 교량의 해석에 있어 단면의 기하학적, 물리적 특성이 중립축을 중심으로 휨-연계 강성 $B_{ij}=0$ 이고, $D_{16}=D_{26}=0$ 임을 고려해야 한다. 각각의 횡방향철근과 수직방향철근은 하나의 lamina로 간주하고, 재료상수는 각각의 lamina의 혼합법칙에 의해서 계산되어진다. 단순지지된 슬래브 교량은 등분포하중과 축하중을 받고 있다. 본 논문에서는 유한차분법과 보 이론에 의해서 해석하였다. 그 결과 보 이론에 의한 해석 값이 판 이론에 의한 해석 값에 근접함을 알 수 있었다. 본 논문에서 얻은 연구 결과를 이용하여 가까운 장래에 학부정도의 실력을 가진 기술자가 포스트텐션된 슬래브 교량의 해석에 있어서 유용하게 사용 할 수 있다.

특별직교이방성 이론에 의한 포스트 텐션된 교량의 해석(II) - 강 판형교 - (Analysis of Post-tensioned Bridge by Specially Orthotropic Laminate Theory (II) - Steel Plate Girder Bridge)

  • 김덕현;원치문;이정호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.141-146
    • /
    • 2001
  • A post-tensioned steel plate girder bridge with cross-beams is analyzed by specially orthotropic laminate theory. The cross-sections of both girders and cross-beams are WF types. The result is compared with that of the beam theory. This bridge with simple support is under uniformly distributed vertical load, and axial loads and moment due to post-tension. In this paper, finite difference method for numerical analysis of simple supported bridge is developed. Relatively exact solution is obtained even with small number of meshes. Theory and analysis method of specially orthotropic laminate plates used in this paper can be used in design of new bridges, and maintenance and repair of old bridges.

  • PDF

포스트텐션을 도입한 넓은 보에서 기둥 폭 내부에 배근된 보강재의 정착비에 따른 비탄성 거동 평가 (Inelastic Behavior of Post-tensioned Wide Beam System with different Reinforcement ratios within Column core)

  • 최윤철;임재형;문정호;이리형;권기혁
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.85-94
    • /
    • 2005
  • PPS(post-tensioned precast concrete system)공법은 U자형 PC로 제작한 넓은 보와 PC 또는 현장 타설 콘크리트로 제작한 기둥으로 구성되며 PC 보와 기둥의 일체성 확보를 위하여 프리스트레스를 도입하였다. 본 연구는 PPS 공법 개발의 일부로 넓은 보의 기둥 폭 내부에 정착되어진 휨철근의 양에 따른 거동특성을 분석하고자 실험적 연구를 수행하였다. 실험체는 기둥 폭내, 외부에 위치한 휭 철근의 양을 달리한 정착비와 동일한 정착비내에서 철근과 긴장재의 양을 주요변수로 하여 대상건물의 내부접합부를 대상으로 1/2크기로 제작하였다. 그 결과 NEHRP 권고사항에서 규정한 한계변위각 0.035까지 내력저하 없이 충분한 내력을 보유하였으며, 보의 휨 파괴가 주요 파괴모드로 접합부에서 전단파괴는 일어나지 않았다. 그리고 넓은 보에 포스트텐션을 도입한 PPS 공법은 기둥 폭 내부의 정착비가 $35\%$인 경우 다소 높은 비틀림 응력을 나타내었으나, 기둥 폭 외부에 위치한 인장철근의 항복 이후 긴장재가 응력을 충분히 발휘함으로서 일체식 구조의 넓은 보-기둥 접합부와 달리 비탄성 이력거동을 통하여 에너지를 효과적으로 소산하였다. 또한 ACI의 proposed provisional standard의 PC 접합부 구조성능 평가지침에 의해 분석한 결과, 모든 실험체에서 허용기준을 모두 만족하고 있으며, 강도의 큰 저하 없이 연성적인 거동을 하고 있음을 알 수 있었다.

철골 모듈러 구조물의 포스트텐션 기둥-바닥 접합부 거동에 대한 해석적 연구 (Analytical Study on Structural Behaviors of Post-Tensioned Column-Base Connections for Steel Modular Structures)

  • 최경석;신동현;김형준
    • 한국전산구조공학회논문집
    • /
    • 제33권6호
    • /
    • pp.427-435
    • /
    • 2020
  • 모듈러 건축물은 철근콘크리트 및 철골 구조물에 비하여 상대적으로 경량이고, 단위 모듈간 기둥의 일체성을 기대하기 어려운 구조적 특성을 가진다. 이와 같은 구조적 특성은 모듈러 건축물의 높이가 높아짐에 따라 바람 및 지진과 같은 횡력저항성능에 직접적인 영향을 미친다. 본 연구에서는 횡력저항성능을 향상시키기 위해 긴장재를 활용한 모듈러 구조시스템을 제안하였다. 모듈러 구조시스템을 구성하는 주요 요소인 포스트텐션 기둥-바닥 접합부는 셀프 센터링 거동을 유도하기 위한 형상 및 상세를 가진다. 포스트텐션 기둥-바닥 접합부의 이력 거동을 상세히 파악하기 위해 유한요소해석을 수행하였으며, 그 결과 초기 긴장력 및 보-기둥 접합부의 접합 조건에 따라 이력 거동은 확연한 차이를 보이는 것으로 나타났다.

2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험 (Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands)

  • 황진하;최승호;이득행;김강수;우운택
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

포스트 텐션 플랫 플레이트 해석을 위한 강성감소계수 (Stiffness Reduction Factor for Post-Tensioned Flat Plate Slabs)

  • 박영미;박진아;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.125-126
    • /
    • 2009
  • 유효보폭 모델은 횡하중하의 포스트 텐션(PT) 플랫 플레이트 골조 해석에 사용된다. PT 플랫 플레이트의 정확한 해석을 위해서 슬래브의 강성감소는 정확하게 평가되어야 한다. 이 목적을 위하여 본 연구는 기존 연구자들의 PT 플랫 플레이트 실험체를 수집하였으며. 반복적인 작업으로 실험체 강성에 수렴하는 유효보폭모델의 강성을 찾기 위하여 슬래브 폭을 감소시켰다. 이러한 데이터를 수집하여 비선형 회귀분석을 통하여 PT 플랫 플레이트의 강성 감소 계수식을 제안하였다.

  • PDF