• Title/Summary/Keyword: position profile generation

Search Result 16, Processing Time 0.02 seconds

Tissue Failure of the Standard-Profile lonescu-Shiley Pericardial Valve in Mitral Position (승모판에서의 표준형 이오네스류 판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1111-1117
    • /
    • 1996
  • Structural deterioration of the bioprosthetic xenograft valves due to primary tissue failure occurs in two modes: from fatigue lesions with tear and wear with or without calcification and from calcification with obstruction. Two groups of consecutive 56 patients with the Hancock porcine ortic valve(HM) and of 1 13 patients with the standard-profile onescu-Shiley bovine pericardial valve(ISM) explanted from mitral position at the time of re-replacement surgery for primary tissue failure at Seoul national University Hospital until 1994, were studied for clinical and pathological features. Their ages at primary implant were 31.9 $\pm$9.2 years In HM and 30.4$\pm$ 12.5 years in ISM. Hemodrnamic dysfunction of the failed mitral bloprostheses were predominantly insufficiency in HM(64.3%) and stenosis in ISM(51.3%)(p<0.001). Pathologic findings of the explanted mitral valves reflected these hemodynamic changes, revealing failure more often from tissue damage(tears and wears) in HM and more often from calcification in ISM(p< 0.001). Explant period(from primary implant to explant) was relatively short in ISM(8.7$\pm$2.6years), compared with the one in HM(10.4 $\pm$2.6 years)(p<0.001). In conclusion, both the Hancock and the lonescu-shiley valves would fail from calcification as well as issue damage. However, while the Hancock porcine valves in mitral position failed more frequently from tissue failure and insufficiency, the standard-profile lonescu-Shiley pericardial valves did from calcification and stenosis, especially in young pAtients . Although the possibility of less occurrence of valve failure from mechanical reasons may be expected with newer generation bloprostheses, it does not seem to Improve durability significantly unless further refinement in antimineralization is achieved. Therefore, clinical use of the glutaraldehyde-treated bioprosthetic valves is, at present, limited to the patients of advanced age groups.

  • PDF

Command Generation Method for High-Speed and Precise Positioning of Positioning Stage (위치결정 스테이지의 고속 정밀 위치결정을 위한 입력성형명령 생성 기법)

  • Jang, Joon-Won;Park, Sang-Won;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.122-129
    • /
    • 2008
  • This paper deals with precise positioning of a high-speed positioning stage without inducing residual vibration by using an input shaping technique. Input shaping is well known to be a very effective tool for suppressing the residual vibration of flexible structures. However, the ordinary input shaping for positioning stages is designated mostly for velocity regulation, not for the residual vibration at the target position. The main difficulties in implementing input shaping along with precise positioning are the time delay caused by the servo system characteristics and the s-curve feature often employed in some motor controllers. This paper analyzes the dynamic responses of a single-mode-dominate stage system subjected to input shaping. A theoretical model is developed io investigate the nature of system. In order to overcome the difficulty, this paper proposes an improved input shaper based on modified command profile generation. The proposed method is proved effective through experiments and simulations.

Generation of Motor Velocity Profile for Walking-Assistance System Using Humanoid Robot Model (휴머노이드 로봇 모델을 이용한 보행재활 훈련장치의 견인모터 속도 파형 생성)

  • Choi, Young-Lim;Choi, Nak-Yoon;Park, Sang-Il;Kim, Jong-Wook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.5
    • /
    • pp.631-638
    • /
    • 2012
  • This work proposes a new method to generate velocity profile of a traction motor equipped in a rehabilitation system for knee joint patients through humanoid robot simulation. To this end, a three-dimensional full-body humanoid robot model is newly constructed, and natural human gait is simulated by applying to it reference joint angle trajectories already published. Linear velocity is derived from distance data calculated between the positions of a thigh band and its traction motor at every sampling instance, which is a novel idea of this paper. The projection rule is employed to kinematically describe the humanoid robot because of its high efficiency and accuracy, and measured joint trajectories are used in simulating human natural gait referring to Winter's book. The attained motor velocity profile for a certain position in human body will be applied to our walking-assistance system which is implemented with a treadmill system.

Modification of conventional X-ray diffractometer for the measurement of phase distribution in a narrow region

  • Park, Yang-Soon;Han, Sun-Ho;Kim, Jong-Goo;Jee, Kwang-Yong;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.407-414
    • /
    • 2006
  • An X-ray diffractometer for spatially resolved X-ray diffraction measurements was developed to identify phase in the narrow (micron-scaled) region of high burn-up fuels and some nuclear materials. The micro-XRD was composed of an X-ray microbeam alignment system and a sample micro translation system instead of a normal slit and a fixed sample stage in a commercial XRD. The X-ray microbeam alignment system was fabricated with a microbeam concentrator having two Ni deposited mirrors, a vertical positioner, and a tilt table for the generation of a concentrated microbeam. The sample micro translation system was made with a sample holder and a horizontal translator, allowing movement of a specimen at $5{\mu}m$ steps. The angular intensity profile of the microbeam generated through a concentrator was symmetric and not distorted. The size of the microbeam was $4,000{\times}20{\mu}m$ and the spatial resolution of the beam was $47{\mu}m$ at the sample position. When the diffraction peaks were measured for a $UO_2$ pellet specimen by this system, the reproducibility ($2{\Theta}={\pm}0.01^{\circ}$) of the peaks was as good as a conventional X-ray diffractometer. For the cross section of oxidized titanium metal, not only $TiO_2$ in an outer layer but also TiO near an oxide-metal interface was observed.

Characterization of the High-temperature Isothermal Aging in USC Ferritic Steel Using Reversible Permeability (가역투자율을 이용한 초초임계압 페라이트기 강의 고온 등온열화 평가)

  • Kim, Chung-Seok;Ryu, Kwon-Sang;Nahm, Seung-Hoon;Lee, Seung-Seok;Park, Ik-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.3
    • /
    • pp.100-105
    • /
    • 2009
  • The high-temperature isothermal aging is studied in ultra-supercritical steel, which is attractive to the next generation of power plants. The effects of microstructure on reversible permeability are discussed. Isothermal aging was observed to coarsen the tempered carbide ($Cr_{23}C_6$), generate the intermetallic ($Fe_2W$) phase and grow rapidly during aging. The dislocation density also decreases steeply within lath interior. The dynamic coercivity, measured from the peak position of the reversible permeability profile decreased drastically during the initial 500 h aging period, and was thereafter observed to decrease only slightly. The variation in dynamic coercivity is closely related to the decrease in the number of pinning sites, such as dislocations, fine precipitates and the martensite lath.

Tissue Failure of the Low-Profile lonescu-Shiley Pericardial Valve in Mitral Position (승모판에서의 단고형 이오네스큐판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.670-676
    • /
    • 1997
  • The structural failure of the glutaraldehyde-treated xenograft valves has been the primary concern about the limited durability as predicted from the begimling of clinical use, and long-term follow-up has shown a significant incidence of primary tissue failure(PTF) from both biological and mechanical reasons. Twenty-seven patients with the low-profile lonescu-Shiley valves explanted from mitral position for PTF(Group III) were studied on the patient characteristics and valve pathology, and the results were compared with the matched observations of the Haycock(Group I) and of the standard-profile lonesiu-Shiley valves(Group II). Patients were aged 16 to 56 years(mean, 38.0$\pm$ 11.0 years), and the size of the failed mitral bioprosthesis was 30.8$\pm$ 1.3 mm. The hemodynamic consequences were stenosis in 29.6%, insufficiency in 44.4%, mixed steno-insufficiency in 14.8%, together with normal function for the rest of patients of prophylactic re-replacement. Pathology revealed calcification with or without tissue damage in 63.0% and tissue damage with or without calcification in 58.l%, in contrast with the observations of predominant tissue damage(76.8%) over calcification in Group I and of calcification(76.1%) over tissue damage in group II. Although dystrophic calcification has long and repeatedly dealt with patient's young age as a determinant of valve durability, such a characteristic evidence was not reached even in patients with calcified valves. Moreover, the prolonged explantation p riods from the studied on the previous report suggested strongly yet possibly evolving destructive processes among the valves in the remaining patients, and awaits further follow-up. In conclusion, PTF of the xenograft valves seems to result from more complicated biologic and metabolic reasons as well as more complex mecharical factors than the reported, and newer generation prostheses, with tissue preservation with glutaraldehyde, do not likely to provide decisive improvement in the occurrence of structural failurebioprostheses is generally limited to the highly aged.

  • PDF