• Title/Summary/Keyword: pore pressure measurement

Search Result 57, Processing Time 0.024 seconds

Numerical modelling of coupled thermo-hydro-mechanical behavior of Heater Experiment-D (HE-D) at Mont Terri rock laboratory in Switzerland (스위스 Mont Terri rock laboratory에서 수행된 암반 히터시험(HE-D)에 대한 열-수리-역학적 복합거동 수치해석)

  • Lee, Changsoo;Choi, Heui-Joo;Kim, Geon-Young
    • Tunnel and Underground Space
    • /
    • v.30 no.3
    • /
    • pp.242-255
    • /
    • 2020
  • The numerical simulations of Heater Experiment-D (HE-D) at the Mont Terri rock laboratory in Switzerland were performed to investigate an applicability of FLAC3D to reproduce the coupled thermo-hydro-mechanical (THM) behaviour in Opalinus Clay, as part of the DECOVLEX-2015 project Task B. To investigate the reliability of numerical simulations of the coupled behaviour using FLAC3D code, the simulation results were compared with the observations from the in-situ experiment, such as temperature at 16 sensors, pore pressure at 6 sensors, and strain at 22 measurement points. An anisotropic heat conduction model, fluid flow model, and transversely isotropic elastic model in FLAC3D successfully represented the coupled thermo-hydraulic behaviour in terms of evolution for temperature and pore pressure, however, performance of the models for mechanical behavior is not satisfactory compared with the measured strain.

Study on Rainfall infiltration Characteristics for Weathered Soils: Analysis of Soil Volumetric Water Content and Its Application (국내 풍화토의 강우 침투특성 분석을 위한 실험연구: 토양 체적함수비 분석 및 적용성 평가)

  • Kim, Man-Il;Chae, Byung-Gon;Cho, Yong-Chan;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.18 no.1
    • /
    • pp.83-92
    • /
    • 2008
  • In order to analyze infiltration characteristics of rainfall in soil, two laboratory experiments were conducted using an amplitude domain reflectometry (ADR) sensor and a pore water pressure meter (PWP) in this study. The first experiment is to understand the dependency of volumetric water content and temperature for standard sand and weathered granite soil. The second experiment is a laboratory flume test with changes of rainfall condition. As the results of the dependency experiment, the volumetric water content is increased with increase of the output voltage measured by the ADR sensor in both the standard sands and weathered granite soil. Furthermore, the results also indicate necessity of consideration of the temperature dependency under the condition of high volumetric water contents from 0.15 to 0.45. In the flume test, two measurement devices are detected to the variation of volumetric water content and pore water pressure at the installation point of the flume. In especial, the measured values of ADR4 and PWP3 installed on the lower part of slope are higher than those of the others. It means that the lower part of slope plays a role of a runoff face and a beginning point of slope failure.

Study of Determination in Measurement System for Safely Managing Debris-Flow (안전한 토석류 관리를 위한 계측기 선정에 관한 연구)

  • Min, Dae-Hong;Yoon, Hyung-Koo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.41-47
    • /
    • 2017
  • Recent studies have shown that there are various systems which can be used to monitor hazardous area in a debris flow location, but lack of methodological research on the exact location where each instrument should be installed has hindered the success of this systems. The objective of this study is to suggest the measurement system for monitoring debris-flow and propose the effective method to determine location of measurement system. Previously studied, from 1991 to 2015, were referred and the applied ratio of every instrument was investigated. The measurement information was divided into 8 categories including rainfall, debris-flow velocity, displacement, fluid pore pressure, ground vibration, image processing, impact force and peak flow depth. The result of this study revealed that the most applied instruments to be rain gauge and geophone for measuring average rainfall and ground vibration respectively. The Analytic Hierarchical Process (AHP) method was selected to determine installation location of instrument and the weighting factors were estimated through fine content, soil thickness, porosity, shear strength, elastic modulus, hydraulic conductivity and saturation. The soil thickness shows highest weights and the fine content relatively demonstrates lowest weights. The score of each position can be calculated through the weighting factors and the lowest score position can be judged as the weak point. The weak point denotes the easily affecting area and thus, the point is suitable for installing the measurement system. This study suggests a better method for safely managing the debris-flow through a precise location for installing measurement system.

Sedimentation & Consolidation Behaviour of Dredged Clay Fill (준설매립 점토지반의 침강 . 압밀거동)

  • 이승원;지성현;유석준;이영남
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.149-156
    • /
    • 2000
  • Sedimentation and self-weight consolidation tests in cylinder and large model tank and field measurement such as settlement and pore water pressure at each layer by wireless automatic instrumentation system were carried out to investigate the behaviour of dredged marine clay fill. The consolidation behaviour for each reclaimed layer was analyzed from these measured data and numerical analysis result using finite strain consolidation theory. It was fond from this study that the consolidation behaviour of dredged clay fill is heavily dependent on the filling process.

  • PDF

Fabrication of Porous Ceramics and Multilayered Ceramics Containing Porous Layers; II. Heterogeneous Laminates (다공성 세라믹스와 다공질층을 포함하는 적층세라믹스의 제조에 관한 연구;II. 불균일 적층소결체)

  • 이해원;윤복규;송휴섭
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1323-1329
    • /
    • 1994
  • Tape casting and lamination were used to produce heterogeneous laminates with alternating layers of different porosity and homogeneous laminates with component layers of the same porosity. The pore structure was investigated for heterogeneous laminates, and bend strength was measured for comparison with that of homogeneous laminates. For a reference, strength measurement was made for the porous body fabricated by sintering samples dry-pressed at low pressure with spray-dried granules. Strength increase, in the range 50~120 MPa, was achieved in the presence of the surface dense layer, while extensive delamination, presumably responsible for enhanced fracture toughness, took place through the internal porous layer.

  • PDF

A novel triaxial testing device for unsaturated soils with measurement of suction and volumetric strains

  • Qian-Feng Gao;Mohamad Jrad;Mahdia Hattab;Said Taibi;Jean M. Fleureau
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.109-122
    • /
    • 2024
  • Standard triaxial cells are commonly used to measure the mechanical behavior of saturated soils. However, this type of standard system is difficult to use for unsaturated soil specimens since it cannot measure the changes in the pore-air volume and pressure. This paper proposes to extend the measurement possibilities of the standard triaxial testing device in a simple way and to adapt it to partially saturated soils. The system is supplied by two hygrometers installed at each end of the cylindrical unsaturated specimen to measure local relative humidity, which allows the derivation of suction. The volumetric strain of the specimen is calculated by analyzing digital photos captured from the outside of the transparent cell wall. Specimens made of kaolin clay, having different hydraulic properties, were tested to verify the reliability of the measurements, and thus, the relevance of the proposed techniques to study the mechanical behavior of unsaturated soils.

A case study on an optimal analysis technique of primary measurements for safety management of fill dam (필댐의 안전관리를 위한 주요 계측 데이터의 최적 분석기법에 대한 사례 연구)

  • Jeon, Hyeoncheol;Yun, Seong-Kyu;Kim, Jiseong;Im, En-Sang;Kang, Gichun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1155-1166
    • /
    • 2021
  • In this study, statistical analysis was performed to suggest the optimal analysis techniques for the main measuring instruments of the fill dam, such as seepage, crest settlement, and porewater pressure gauge. In addition, correlation analysis with water level and rainfall data was performed. Based on the results of descriptive statistical analysis for each instrument, porewater pressure gauges could be classified into 3 groups or 2 groups through principal component analysis, In the case of the group having a high correlation with the water level instrument, the correlation between the gauges was also large. In the case of seepage instrument, the distribution showed an extremely asymmetric distribution, so for quantitative analysis, the average seepage during non-precipitation and precipitation could be estimated through decision tree analysis. In the case of the crest settlement instrument, the correlation analysis showed that the correlation between the gauges was large, but the relationship with the water level instrument did not show a significant linear relationship, so EMD analysis was performed to analyze it in more detail. It is judged that principal component analysis, decision tree analysis, and data filtering method can be applied to analyze the behavior of pore water pressure meters, seepage, and crest settlement instrument as major measurement items of fill dam.

A Development of Embankment Stability Evaluation Method on Soft Foundation (연약지반상의 흙쌓기 안정관리 기법 개발)

  • Kim, Jeong-Seon;Chang, Yong-Chai;Park, Sung-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.9
    • /
    • pp.43-54
    • /
    • 2013
  • This study proposed a new embankment stability control method to analyze the measurement data on the slope activities of the soft ground, using the Stability Control Index (SCI) obtained from the p-q stress paths. In order to validate this new technique, the data from triaxial compression tests (CU) and field measurement were compared. SCI is calculated from the current path of the effective stress points ($p^{\prime}=p-{\Delta}u$) using the relative position between the Total Stress Path $p_{max}$ and the point of $k_f$ line $p_f$. From this result, the point of effective stress $p^{\prime}(=p-{\Delta}u)$ will have access to the point $p_f$ of $k_f$ line when the pore water pressure occurs or the point of total stress pass $p^{\prime}_{max}$ when the pore pressure dissipates. Thus, the Stability Control Index (SCI) can evaluate quantitatively the safety of embankment from the relative position of the effective stress path.

Correction for Membrane Penetration Effect during Isotropic Unloading and Undrained Cyclic Shear Process (등방제하과정과 반복전단과정에서의 멤브레인 관입량 및 보정식에 대한 실험적 고찰)

  • Kwon, Youngcheul;Bae, Wooseok;Oh, Sewook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.201-207
    • /
    • 2006
  • Soil tests are generally conducted using a membrane to measure a pore water pressure. However, it has also been recognized that the membrane penetrates into the specimen by the change of the confining pressure, and it results in the erroneous measurement in the pore water pressure and the volumetric strain. This study examined the effectiveness of the correction equation of the membrane penetration on the basis of the experimental data acquired during the isotropic unloading and the cyclic shear process using the hollow cylindrical shear test equipment. The results showed that the membrane penetration by the correction equation could be overestimated when the mean effective stress was lower than 20kPa in this study. The limitations originated from the sudden increase near the zero effective stress, and in order to prevent the overestimation in low effective stress condition, the use of the constant a was proposed in this study. Furthermore, the correction equation for the membrane penetration had to be applied carefully when the initial relative density was high and the density changes were occurred by the relocation of the soil particle by the liquefaction.

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF