• Title/Summary/Keyword: polyvinyl siloxane impression material

Search Result 11, Processing Time 0.023 seconds

Comparative study on properties of commercial polyvinyl siloxane impression materials (시판 폴리비닐실록산 인상재의 물성에 관한 비교연구)

  • Kang, Jae-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF

The Property Change of Silicone Impression Materials with Change of Storage Temperature (실리콘 인상재의 보관온도에 따른 특성변화)

  • Oh, Sang-Hwan;Moon, Seung-Kyun;Kim, Kyoung-Nam
    • Journal of dental hygiene science
    • /
    • v.10 no.6
    • /
    • pp.459-464
    • /
    • 2010
  • The purpose of this study was to evaluate the physical properties of hydrophilic polyvinyl siloxane impression materials as change of material's storage temperatures. Working time, strain-in-compression, elastic recovery and consistency were tested according to ISO Standard NO. 1563. The results are as followed. 1. Working time decreased in cold storage. 2. Strain-in-compression was different in storage temperatures. Material's strain-in compression in cold temperatures were higher than in room temperature and in incubator. 3. A coefficient of elastic recovery varied by storage temperatures. The rate in cold temperature was the lowest and in incubator was the highest. 4. Consistency of impression substance different in storage temperatures. The extent in cold temperature is the highest and in incubator was the lowest. Statistical analysis(SPSS 14.0k, p>0.05) showed that storage temperature affect to material's physical properties. We recognized that the physical properties of polyvinyl siloxane impression materials were changed according to storage temperature.

A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION (수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구)

  • Song, Ki-Yong;Yang, Jae-Ho;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS (부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구)

  • Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS (탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구)

  • Kim, Kee-Hong;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS (DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구)

  • Kown, O-Teak;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.