• Title/Summary/Keyword: polymerization time

Search Result 515, Processing Time 0.032 seconds

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.126-131
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to examine the curing efficiency of various resin-based materials polymerized through ceramic restorations with 3 different thicknesses. Curing efficiency was evaluated by determining the surface microhardness (VHN) of the resin specimens. MATERIALS AND METHODS. Four kinds of resin materials were used. Z350 (3M ESPE $Filtek^{TM}$ Z350: A2 Shade), Z250 (3M ESPE $Filtek^{TM}$ Z250: A2 Shade) and $Variolink^{(R)}$ II (VL: Ivoclar vivadent, base: transparent) either with or without a self-curing catalyst (VLC: Ivoclar vivadent, catalyst: low viscosity/transparent) were filled into the silicone mold (10 mm diameter, 1 mm thick). They were cured through ceramic discs (IPS e.max Press MO-0 ingot ivoclar vivadent, 10 mm diameter, 0.5, 1 and 2 mm thicknesses) by LED light-curing units for 20 and 40 seconds. Vicker's microhardness numbers (VHNs) were measured on the bottom surfaces by a microhardness tester. Data were analyzed using a 3-way analysis of variance (ANOVA) at a significance level of 0.05. RESULTS. The thickness of ceramic disc increased, the VHNs of all four resin types were decreased (P<.05). The mean VHN values of the resins light cured for 40 seconds were significantly higher than that of LED for 20 seconds in all four resin materials (P<.05). VLC showed significantly higher VHN values than VL regardless of other conditions (P<.05). Z350 and Z250 showed higher values than VL or VLC (P<.01). CONCLUSION. Thinner ceramic disc with increased curing time resulted higher VHN values of all resin materials. The use of a catalyst produced a greater hardness with all polymerization methods. Restorative resin materials (Z350, Z250) showed higher VHN values than resin cement materials (VL, VLC).

Effects of Separator Carbonization on the Characteristics of Aluminium Polymer Condenser (알루미늄 고분자 콘덴서의 특성에 대한 절연지 탄화의 영향)

  • Kim, Jae Kun;Yu, Hyung Jin;Hong, Yoong He;Park, Mi Jin;Park, Seung Youl
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.539-546
    • /
    • 2006
  • A study on the polymerization of polyethylenedioxythiophene (PEDOT) and the carbonization process of a separator was carred out in order to apply conductive polymer PEDOT to the winding typed aluminum condenser as a solid electrolyte and a negative electrode. PEDOT was polymerized with ethylenedioxythiophene (EDOT) as a monomer and ferric-p-toluenesulfonate as an oxidizing agent. The separator of condenser element was carbonized to control its fibrous tissue for the purpose of making it easy to impregnate the PEDOT solution into the microporous etched pit of aluminum foil by preventing separator from concentrating the PEDOT solution on itself. The characteristics of condenser such as capacitance, dissipation factor, equivalent series resistance, and thermal resistance depended on a carbonization temperature and a carbonization time. It was found that a thickness and a density of the used separator were major parameters of carbonization process and the characteristics of condenser were affected by these parameters.

Adhesion Behavior of Graphene Oxide on Spherical Polymer Particles (그래핀 산화물-구형 고분자 입자 사이의 흡착 거동)

  • Kim, Sinwoo;Lee, Sang-Soo;Lee, Jonghwi
    • Polymer(Korea)
    • /
    • v.37 no.2
    • /
    • pp.162-166
    • /
    • 2013
  • Graphene-coated polymer particles have attracted research interests due to their emerging applications derived from their controlled structure and morphology. To control the properties of graphene oxide (GO)-polystyrene (PS) composite particles, the adsorption time and instantaneous adsorption conditions were investigated by varying their mixing method. Polystyrene particles prepared by emulsion polymerization were modified to have positive surface charge by adsorption of polyethylene imine (PEI) on the surface of PS particles. GO prepared by the chemical exfoliation method had negative surface charge from the oxygenated groups. The adsorption of the negatively charged GOs onto the positively charged PS particles was successfully completed, and it was found that a longer adsorption time and a greater difference in the instantaneous relative concentration led PS-GO particles to have more homogeneously coated surfaces without aggregation.

Effect of Liquid Isoprene Rubber on the Adhesion Property of UV Curable Acrylic Pressure-Sensitive Adhesive (액상 이소프렌 고무가 자외선 경화형 아크릴 점착제의 점착 특성에 미치는 영향)

  • Lee, Jiye;Chung, Kyungho
    • Elastomers and Composites
    • /
    • v.49 no.3
    • /
    • pp.210-219
    • /
    • 2014
  • In this study, the acrylic pressure sensitive adhesive (PSA) for the optical functionality sheet was prepared by blending liquid isoprene rubber. The acrylic PSA was synthesized with butyl acrylate, acrylic acid, 2-ethylhexyl acrylate and 2-hydroxyethyl methacrylate. Toluene was used to a solvent for polymerization. Liquid isoprene rubber (LIR-50) was blended with the acrylic PSA and blend ratio was 0 ~ 50 wt%. According to the results, the adhesive transfer, which was the big problem of acrylic adhesive, was reduced with the addition of LIR-50. The secondary bonding of LIR-50 with substrate did not occurred due to absence of polar group in LIR-50. The peel strength and adhesive transfer were decreased by UV curing and the degreed of decrease depended on the amounts of photoinitiator and UV irradiation time. On the other hand holding power increased drastically by increasing amounts of photoinitiator and UV irradiation time.

Linear Low Density Polyethylene Preparation by Titanium-Based Ziegler-Natta Catalysts (티탄이 기본인 Ziegler-Natta 촉매에 의한 선형저밀도폴리에틸렌의 제조)

  • Dong-Ho Lee;Kyung-Eun Min;Cha-Ung Kim
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.110-117
    • /
    • 1987
  • For the preparation of linear low density polyethylene (LLDPE), the copolymerization of ethylene and 1-butene was carried out with various catalysts of titanium alkoxidealkylaluminum compound in slurry phase. The effects of catalyst components, aging time, concentration of catalyst components, polymerization time and temperature on the catalytic activity and copolymer composition were examined. The properties of copolymer obtained were also considered with the correlation to the 1-butene contents. It has been found that the titanium tetra-n-butoxide-diethylaluminum chloride catalyst system was the most suitable for the production of LLDPE with higher catalytic activity, more 1-butene content and less soluble parts. The density, glass transition temperature, melting point and heat of fusion of copolymer were decreased with increasing 1-butene contents.

  • PDF

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY (도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구)

  • Kim, Seung-Soo;Cho, Sung-Sik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

A STUDY ON THE EFFECTS OF FINISHING/POLISHING TIMING ON SURFACE FEATURES OF COMPOSITE RESTORATION (연마시기에 따른 복합레진의 표면 특성에 관한 연구)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Park, Eun-Hae;Lee, Young-Jun;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2004
  • Proper finishing/polishing of dental restorations are critical clinical procedures that enhance both esthetics and longevity of restored teeth. This study was to compare the effects of immediate and delayed finishing/polishing procedures on the surface roughness and surface hardness of tooth-colored restoratives including two microfilled composite resins, such as Filtek A110 and Silux Plus, two hybrid composite resins, such as Revolution formular2 and Palfique Estelite. A total of 48 specimens were made for each material. The first 16 specimens served as the control group and the remaining 32 specimens were randomly divided into two equal groups. The control group was stored in distilled water at $37^{\circ}C$ for 1 week after light polymerization against the Mylar sheet. The first experimental group was finished/polished immediately after light polymerization and stored for 1 week in distilled water at $37^{\circ}C$, whereas the while the second group was finished/polished 1 week after light polymerization and stored in distilled water at $37^{\circ}C$. The results were as follows: 1. The smoothest surface was produced by Mylar sheet and finishing/polishing procedure increased the surface roughness. However, the surface roughness of composite resins were not influenced by the finishing/polishing timing. 2. There were significant differences about surface roughness between Revolution formular 2 and Silux Plus, regarding immediate finishing/polishing, and between Palfique Estelite and Silux Plus regarding delayed finishing/polishing(p<0.05). 3. The sequence of the surface hardness was ascending order by Revolution formular 2, Silux Plus, Filtek A110 and Palfique Estelite. However there were no significant differences about hardness among the control group and two finishing/polishing timing groups. 4. The effects of finishing/polishing time on surface roughness and hardness appeared to be material-dependent.

  • PDF

Evaluation of Microhardness of Bulk-base Composite Resins According to the Depth of Cure (Bulk-base 복합 레진의 중합 깊이에 따른 미세경도 평가)

  • No, Yoomi;Shin, Bisol;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.335-340
    • /
    • 2017
  • Composite resin becomes an essential material in pediatric dentistry. However, incremental filling of composite resin to minimize the polymerization shrinkage takes time. To reduce the polymerization shrinkage, clinicians and researchers have focused on bulk-filling materials. Bulk-base composite resin is newly introduced as bulk-filling composite resin. The purpose of this study was to evaluate microhardness profile of bulk-base composite resin according to the depth of cure. A high flow bulk-base material and a low flow bulk-base material were used for experimental group, and a conventional composite resin was used for control group. Each group consist of 20 specimens, $3.5{\times}3.5{\times}5.0mm$ mold was used to make specimen. Specimens were sectioned at the 2 mm and the 3 mm depth with milling machine. Microhardness profile was measured at the surface, 2 mm depth, 3 mm depth, and 4 mm depth. Microhardness of control group showed statistically significant difference (p < 0.05) according to the polymerization depth. In contrast, experimental group showed no statistically significant difference, except between 0 mm and 4 mm at HFB, 0 mm and 2 mm, 0 mm and 3 mm at MFB. At the surface and the 2 mm depth, the control group showed higher microhardness than the experimental groups (p < 0.05). However, at the 4 mm depth, the experimental groups showed significantly higher microhardness (p < 0.05). The results from this study, the bulk-base composite resin showed higher microhardness at the 4 mm and lower microhardness at the surface and the 2 mm depth. Therefore, if bulk-base resin overcomes the mechanical weakness, it could be considered using in pediatric dentistry.

Reduction of causative organisms associated with dental caries and alteration of oral hygiene status in connection with toothbrushing instruction for preschool children (미취학 아동의 칫솔질 교육에 따른 치아우식원인균 감소와 구강위생상태 변화)

  • Song, Ji-Na;Cho, Myung-Sook;Lee, Min-Kyung;Yu, Su-Bin;Kim, Sun Il;Kim, Hye-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.831-842
    • /
    • 2018
  • Objectives: This study was conducted to reveal the biological basis of dental plaque and preschool children's dental health status through repetitive and continuous toothbrushing instruction to preschool children, using quantitative criteria, and to emphasize the importance of the role of an oral health manager for the prevention of dental caries. Methods: After IRB approval, toothbrushing instruction and oral microbial specimen collection were conducted with children of preschool age at the Daycare Center attached to D. University, Busan. Specimens from 27 children were characterized by analysis with real-time multi-chain enzymatic polymerization reaction technique at an agency specializing in genetic analysis. Results: In a survey of the children's dental health behaviors, 48.1% responded that the toothbrushing time is 91 to 150 seconds; 66.7% responded that the frequency of toothbrushing is more than three times per day; 81.5% stated that they performed tongue brushing; and 81.5% brushed their teeth. Regarding levels of dental cariogenic bacteria, after children received continuous toothbrushing instruction, there were reductions in both Streptococcus mutans and Streptococcus sobrinus. Regarding toothbrushing time, the time increased in relation to the presence of instruction. Regarding Quigley Hein Index, the index decreased in the early and middle periods upon addition of instruction, then increased in the middle and later periods. Conclusions: Through persistent and repetitive toothbrushing instruction, healthy behavior can be positively established in children of preschool age; it is necessary to prepare institutional measures so opportunities for dental health education can be consistently provided and maintained. In the future, it will be necessary to conduct a follow-up study to verify the factors affecting toothbrushing time and volume of oral pathogens.