• 제목/요약/키워드: polymeric membrane

검색결과 315건 처리시간 0.031초

공기 분리용 열분해 탄소막 (Pyrolytic Carbon Membranes for Air Separations)

  • Singh, Anshu;Koros, W.J.
    • 멤브레인
    • /
    • 제7권1호
    • /
    • pp.15-21
    • /
    • 1997
  • Carbon molecular sieve (CMS) membranes were synthesized by the pyrolysis of polymeric precursors. The CMS materials had oxygen-nitrogen selectivities much higher than those observed for the polymeric precursors. Typically molecular sieving materials have diffusion selectivities much higher than polymeric materials. This has been identified as a result of higher entropic selectivity of the molecular sieving materials. A study of the development of molecular sieving properties as the polymeric precursor is pyrolyzed into a CMS material will offer us an insight into polymeric molecular structures needed for enhanced entropic selectivity membrane materials.

  • PDF

Modification of polyethersulfone hollow fiber membrane with different polymeric additives

  • Arahman, Nasrul;Mulyati, Sri;Lubis, Mirna Rahmah;Razi, Fachrul;Takagi, Ryosuke;Matsuyama, Hideto
    • Membrane and Water Treatment
    • /
    • 제7권4호
    • /
    • pp.355-365
    • /
    • 2016
  • The improvement of fouling resistance of porous polymeric membrane is one of the most important targets in membrane preparation for water purification in many process like wastewater treatment. Membranes can be modified by various techniques, including the treatment of polymer material, blending of hydrophilic polymer into polymer solution, and post treatment of fabricated membrane. This research proposed the modifications of morphology and surface property of hydrophobic membrane by blending polyethersulfone (PES) with three polymeric additives, polyvinylpyrrolidone (PVP), Pluronic F127 (Plu), and Tetronic 1307 (Tet). PES hollow fiber membranes were fabricated via dry-wet spinning process by using a spinneret with inner and outer diameter of 0.7 and 1.0 mm, respectively. The morphology changes of PES blend membrane by those additives, as well as the change of performance in ultrafiltration module were comparatively observed. The surface structure of membranes was characterized by atomic force microscopy and Fourier transform infra red spectroscopy. The cross section morphology of PES blend hollow fiber membranes was investigated by scanning electron microscopy. The results showed that all polymeric additives blended in this system affected to improve the performances of PES membrane. The ultra-filtration experiment confirmed that PES-PVP membrane showed the best performance among the three membranes on the basis of filtration stability.

Modified membrane with antibacterial properties

  • Aryanti, P.T.P.;Sianipar, M.;Zunita, M.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.463-481
    • /
    • 2017
  • Bacteria have been considered as a major foulant that initiates the formation of biofilm on the polymeric membrane surface. Some polymeric membranes are naturally antibacterial and have low fouling properties, however, numerous efforts have been devoted to improve their antibacterial performance. These modifications are mostly carried out through blending the membrane with an antibacterial agent or introducing the antibacterial agent on the membrane surface by chemical grafting. Currently, a significant number of researches have reported nanocomposite membrane as a new approach to fabricate an excellent antibacterial membrane. The antibacterial nanoparticles are dispersed homogenously in membrane structure by blending method or coating onto the membrane surface. Aim of the modifications is to prevent the initial attachment of bacteria to membrane surface and kill bacteria when attached on the membrane surface. In this paper, several studies on antibacterial modified membranes, particularly for water treatment, will be reviewed comprehensively. Special attention will be given on polymeric membrane modifications by introducing antibacterial agents through different methods, such as blending, grafting, and coating.

Harvesting of microalgae via submerged membranes: flux, fouling and its reversibility

  • Elcik, Harun;Cakmakci, Mehmet
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.499-515
    • /
    • 2017
  • The purpose of this study was to investigate membrane fouling caused by microalgal cells in submerged membrane systems consisting of polymeric and ceramic microfiltration membranes. In this study, one polymeric (flat-sheet, pore size: $0.2{\mu}m$) and two ceramic (flat-sheet, pore size: $0.2{\mu}m$ and cylindrical, pore size: $1{\mu}m$) membranes were used. Physical cleaning was performed with water and air to determine the potential for reversible and irreversible membrane fouling. The study results showed that substantial irreversible membrane fouling (after four filtration cycles, irreversible fouling degree 27% (cleaning with water) and 38% (cleaning with air)) occurs in the polymeric membrane. In cleaning studies performed using water and air on ceramic membranes, it was observed that compressed air was more effective (recovery rate: 87-91%) for membrane cleaning. The harvesting performance of the membranes was examined through critical flux experiments. The critical flux values for polymeric membrane with a pore size of $0.20{\mu}m$ and ceramic membranes with a pore size of $0.20{\mu}m$ and $1{\mu}m$ were ${\leq}95L/m^2hour$, ${\leq}70L/m^2hour$ and ${\leq}55L/m^2hour$, respectively. It was determined that critical flux varies depending on the membrane material and the pore size. To obtain more information on membrane fouling caused by microalgal cells, the characterization of the fouled polymeric membrane was performed. This study concluded that ceramic membranes with a pore size of $0.2-1{\mu}m$ in the submerged membrane system could be efficiently used for microalgae harvesting by cleaning the membrane with compressed air at regular intervals.

Liquid Crystal Based Optical Sensor for Imaging Trypsin Activity at Interfaces Between Aqueous Phases and Thermotropic Liquid Crystals

  • Zhang, Minmin;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2973-2977
    • /
    • 2013
  • In this study, we developed a liquid crystal (LC)-based optical sensor for monitoring enzymatic activity through orientational changes in liquid crystals (LCs) coupled to the properties of a poly-${\small{L}}$-lysine (PLL)-based polymeric membrane. We prepared a PLL-based polymeric membrane at the planar interface between the thermotropic liquid crystal and aqueous phases. The PLL-based polymeric membrane was obtained by contacting the PLL solution with water immiscible LCs, 4-cyano-4'-pentyl-biphenyl (5CB) doped with adipoyl chloride. We then investigated the membrane properties by examining the permeability of the membrane to phospholipids, 1,2-didodecanoyl-rac-glycero-3-phosphocholine (DLPC). The permeability of the membrane to transport phospholipids was monitored through the orientational transition of 5CB in contact with the dispersions of DLPC. Since trypsin can enzymatically catalyze the hydrolysis of PLL, we incubated an aqueous trypsin solution with the membrane for 2 h at room temperature to cause an increase in the permeability of the polymeric membrane to DLPC. As a result, a bright to dark optical shift of LCs was observed, which implied that an enzymatic reaction between trypsin and PLL-based membrane occurred. Two control experiments using chymotrypsin and bovine serum albumin (BSA) revealed no sign of improved permeability based on the orientational transition of LCs.

Cleaning agents efficiency in cleaning of polymeric and ceramic membranes fouled by natural organic matter

  • Urbanowska, Agnieszka;Kabsch-Korbutowicz, Malgorzata
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Ultrafiltration is known to be one of the most commonly applied techniques in water treatment. Membrane fouling is the main limiting factor in terms of process efficiency and restricting it to the manageable degree is crucial. Natural organic matter is often found to be a major foulant in surface waters. Among many known fouling prevention techniques, the membrane chemical cleaning is widely employed. This study focuses on evaluating the cleaning efficiency of polymeric and ceramic membranes with the use of various chemicals. The influence of cleaning agent type and its concentration, membrane material and its MWCO, and cleaning process duration on the recovery of membrane flux was analyzed. Results have shown that, regardless of membrane type and MWCO, the most effective cleaning agent was NaOH.

고분자 중공사막 모듈을 이용한 미세기포 발생과 이미지 분석기법을 이용한 기포 특성 파악 (Utilization of Image Analysis Technique for Characterization of Micro-Bubbles Generated by Polymeric Membrane Module)

  • 김준영;장인성
    • 대한환경공학회지
    • /
    • 제33권6호
    • /
    • pp.447-452
    • /
    • 2011
  • 본 연구에서는 고분자 중공사막 모듈을 산기 도구로 사용하여 미세 기포 발생을 도모하였고 영상정보를 기반으로 하는 이미지 분석 기법을 적용하여 발생한 기포 특성을 파악하고자 하였다. 기포의 이미지 분석 결과, 고분자 중공사막 모듈을 통해 수중에 분사된 기포는 산기석을 통한 기포보다 약 30~64% 작은 크기로 발생되는 것을 관찰하였고, 기포의 70% 이상이 0.2~0.82 mm 범위에 분포된 반면, 산기석의 경우는 0.77~1.08 mm의 범위에 속한 기포가 80% 이상이었다. 산기석과 고분자 중공사막모듈을 각각 기포발생 장치로 사용한 부상조를 운영하였을 때 반응조에 잔존하는 플록의 크기는 산기석을 이용했을 때가 고분자 중공사막 모듈의 경우보다 더 큰 것으로 나타났다. 이는 고분자 중공사막 모듈에 의해 발생한 미세기포가 충돌 효율의 증가 때문에 크기가 작은 콜로이드 입자들까지 응집/부상할 수 있는 기회를 제공하였기 때문이다. 따라서 부상공정에 고분자 중공사막모듈을 산기장치로 활용하였을 경우 응집부상 제거효율이 증가할 수 있는 가능성을 보였다. 또한 본 연구에서 사용한 이미지 분석기법은 제공된 영상정보를 기반으로 기포의 기초 특성들과 관련된 정보습득을 위한 분석도구로 활용될 수 있을 것으로 판단된다.

고분자 미세입자의 전기분사와 다공성 박막 제작에의 응용 (Electrospraying of Polymeric Microparticles and its Application to Fabrication of Porous Membrane)

  • 정영훈;오하나
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.126-133
    • /
    • 2015
  • Recently, there has been demand for polymeric porous membranes in various fields, such as environmental engineering, pharmaceutics, tissue engineering, drug delivery, biology, and fuel cells. In this study, it is proposed that a polymer particle-based porous membrane can be fabricated using electrospraying and sintering processes. Electrospraying can fabricate polymeric particles with diameters ranging from several micrometers to tens of nanometers without the cumbersome particle aggregation problem. Additionally, the particles can be sintered through thermo-compression under the glass transition temperature. In this study, a polymethyl methacrylate particle-based porous membrane with an average pore size of less than 500 nm is fabricated using the proposed method.

Polymeric Iodide-ion Selective Electrodes Based on Urea Derivative as an Ionophore

  • Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권12호
    • /
    • pp.1985-1988
    • /
    • 2006
  • The polymeric membrane electrodes based on urea derivative as an ionophore were prepared and studied for the iodide-ion selective electrode. This membrane exhibits a linear stable response over a wide concentration range ($1.0\;{\times}\;10^{-5}\sim1.0\;{\times}\;10^{-2}$) with a slope of -57.7 mV/decade, a detection limit of log[$I^-$] = -5.63, and a selectivity coefficient for iodide against perchlorate anion (log$K^{pot}_{I^-,j}$ = -1.42). The selectivity series of the membrane gives the follow as $I^-$ > $SCN^-$, $Sal^-$ > $ClO_4^-$ > $NO_3^-$ > $Br^-$ > $NO_2^-$ > $Cl^-$ > $F^-$. The proposed electrode showed good selectivity and response for iodide anion over a wide variety of other anions in pH 5.0 buffer solutions.

고분자 지질막 전극 센서의 맛 반응 평가 (Taste Response of Electrodes Coated with Polymeric Lipid Membrane)

  • 조용진;박인선;김남수
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.249-258
    • /
    • 2002
  • The fourteen different electrodes coated with polymeric lipid membrane were evaluated to selectively monitor the sweet, salty, sour and bitter tastes, and umami. The polymeric lipid membrane consisted of the three components, or polymer matrix, plasticizer and electroactive material, the compositional ratio of which was 1:1.25:1. Herein, the 14 different electroactive materials were used. Sucrose, NaCl, citric acid, caffeine and MSG were used as standard materials of sweet, salty, sour and bitter tastes, and umami. The linear responses of each electrode regarding 5 tastes were analyzed by means of the correlation coefficient between electric potential difference and concentration of a taste material when the linearity was based on a linear model and a thermodynamic model, respectively. As fur salty taste, the electrode coated with valinomycin had a selective linearity at the significance level of 0.01. For monitoring sweet taste, the electrode with oleylamine and the electrode with the mixture of tai-n-octylmethylammonium chloride and dioctylphosphate (2:8) showed the significant linearities at the levels of 0.05 and 0.10, respectively.