• Title/Summary/Keyword: polymeric insulator

Search Result 61, Processing Time 0.042 seconds

Evaluation of Effects of Impurities on Insulating Properties of Polymeric Insulator in Power Distribution Cable (배전케이블내 고분자 절연체의 절연성능에 미치는 불순물의 영향평가)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1402-1404
    • /
    • 1997
  • To evaluate the effects of impurities on insulating properties of polymeric insulator in high electric power distribution cable, OIT and OMT were measured. By using Eyring plot, the thermodynamic parameters of ${\Delta}H$ and ${\Delta}S$ could be obtained.

  • PDF

Photoinitiator-free Photosensitive Polyimide Gate Insulator for Organic Thin Film Transistor

  • Pyo, Seung-Moon;Lee, Moo-Yeol;Jeon, Ji-Hyun;Son, Hyun-Sam;Yi, Mi-Hye
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.885-888
    • /
    • 2004
  • We have prepared and investigated the properties of photoinitiator-free photosensitive polyimide gate insulatos for organic thin-film transistors (OTFTs). The precursor was prepared from a dianhydride, 3,3',4,4'-Benzophenone tetracarboxylic dianhydride (BTDA) and novel aromatic diamine, 7-(3,5-diaminobenzoyloxy) coumarine (DA-CM). Photo-patternability of the polyimide precursor film and surface morphology of the films before and after photo-patterning process were investigated and negative pattern with a resolution of 50 ${\mu}m$ was obtained nicely. In addition, we have fabricated OTFTs with pentacene and photosensitive polyimide as a semiconductor and a gate insulator; respectively. According to the device geometry, the ${\mu}$, current modulation ratio and subthreshold swing of the devices were around 0.2${\sim}$0.4 $cm^2$/Vs, more than $10^5$ and around 3${\sim}$5 V/dec, respectively.

  • PDF

Study on the Characteristics of Organic TFT Using Organic Insulating Layer Efficiency (유기 절연층에 따른 유기 TFT 특성 연구)

  • Pyo, Sang-Woo;Lee, Min-Woo;Sohn, Byung-Chung;Kim, Young-Kwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.335-338
    • /
    • 2002
  • A new process for polymeric gate insulator in field-effect transistors was proposed. Fourier transform infrared absorption spectra were measured in order to identify ODPA-ODA polyimide. Its breakdown field and electrical conductivity were measured. All-organic thin-film transistors with a stacked-inverted top-contact structure were fabricated to demonstrate that thermally evaporated polyimide films could be used as a gate insulator. As a result, the transistor performances with evaporated polyimide was similar with spin-coated polyimide. It seems that the mass-productive in-situ solution-free processes for all-organic thin-film transistors are possible by using the proposed method without vacuum breaking.

The Evaluation of Reliability through the Field Test of Pormeric Long Rod Insulator for Rail Way (전철용 고분자 장간애자의 실증 시험을 통한 신뢰성 평가)

  • 홍진영;김영성;백주흠;박찬기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.229-232
    • /
    • 1997
  • In this paper, we describe about the field test of polymeric long rod insulator for rail way. For the test, insulators were mounted at the feeder line system at Kuro base station and were exposed to environmental, electric, and mechanical stress. During the test service, the leakage current was been monitoring and stored the data by the leakage current measuring system that was specially constructed. After about 6 months, diagnostic tests for evaluation of the installed insulators were conducted. The test results developed that the developed polymeric insulator is valid to use for rail way.

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

Multi-Stress Aging Test Technology for Suspension Polymer Insulator (폴리머 현수애자의 복합가속열화 평가기술)

  • Park, Hoy-Yul;Kang, Dong-Pil;Kim, Ik-Soo;Shin, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF

Effects of processing temperature and optical anisotropy of a polymeric insulator on organic thin-film transistors

  • Bae, Jin-Hyuk;Kim, Won-Ho;Na, Jun-Hee;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1107-1110
    • /
    • 2006
  • We investigate the effect of processing temperature of gate insulator and optical anisotropy on organic thin-film transistors (OTFTs). The insulator film which was processed lower temperature than solvent boiling temperature can lead more aligned pentacne molecules compare to higher processed insulator film. It finally gives rise to the big increase of carrier mobility in OTFTs, although there are little difference at the seriously affecting properties to device performance, for example roughness of gate insulator film.

  • PDF

Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials (폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술)

  • Ahn, Myeong-Sang;Park, Hoy-Yul;Na, Moon-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I) (송전용 폴리머 애자의 산불영향 신뢰성 평가(I))

  • Choi, In-Hyuk;Lee, Il-Dong;Jeon, Young-Joon;Lee, Chul-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF