• 제목/요약/키워드: polymer sheet

검색결과 327건 처리시간 0.019초

무기질계 탄성 도막재와 고무 아스팔트를 적층한 일체형 방수재의 시공특성에 관한 실험적 연구 (A study on a performance the appliable rubber asphalt of monolithic waterproofing material of construction quality and the cement polymer modified waterproof coating membrane material of surface treatment.)

  • 박진상;최성민;박영태;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.223-226
    • /
    • 2005
  • In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing ,Fing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.

  • PDF

Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.149-166
    • /
    • 2012
  • This paper presents an experimental investigation on the performance of 2.5 m long reinforced concrete (RC) T-beams strengthened in shear using epoxy bonded glass fibre fabric. Eighteen (18) full scale, simply supported RC T-beams are tested. Nine beams are used as control beam specimens with three different stirrups spacing without glass fibre reinforced polymer (GFRP) sheet and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in the form of U-jacket around the web of T-beams for each type of stirrup spacing. The objective of this study is to evaluate the effectiveness, the cracking pattern and modes of failure of the GFRP strengthened RC T-beams. The test result indicates that for RC T-beams strengthened in shear with U-jacketed GFRP sheets, increase the load carrying capacity by 10-46%.

상온 ECR-MOCVD에 의해 제조되는 Cu/C박막특성 (Characteristics of copper/C films on PET substrate prepared by ECR-MOCVD at room temperature)

  • 이중기;전법주;현진;변동진
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.44-53
    • /
    • 2003
  • Cu/C films were prepared at room temperature under $Cu(hfac)_2-Ar-H_2$ atmosphere in order to obtain metallized polymer by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The room temperature MOCVD on polymer substrate could be possible by collaboration of ECR and a DC bias. Structural analysis of the films by ECR was found that fine copper grains embedded in an amorphous polymer matrix with indistinctive interfacial layer. The increase in $H_2$ contents brought on copper-rich film formation with low electric resistance. On the other hand carbon-rich films with low sheet electric resistance were prepared in argon atmosphere. The electric sheet resistance of Cu/C films with good interfacial property were controlled at $10^8$~$10^0$ Ohm/sq. ranges by the $H_2$/Ar mole ratio and the shielding effectiveness of the film showed maximum up to 45dB in the our experimental range.

전도성 고분자가 코팅된 탄소 나노튜브 투명전극의 특성 분석 (Characterization of Transparent Electrodes using Carbon Nanotubes Coated by Conductive Polymers)

  • 김부종;한상훈;박진석
    • 반도체디스플레이기술학회지
    • /
    • 제13권1호
    • /
    • pp.19-25
    • /
    • 2014
  • This study demonstrates transparent electrodes with characteristics desirable for touch screen panels using carbon nanotubes (CNTs). This has been accomplished by depositing CNTs on glass substrates via spray coating and then depositing thin conductive polymer films on the CNTs via spin coating. For all of the samples, such as CNTs, conductive polymers, and polymer-coated CNTs, the surface morphologies, sheet resistances, visible transmittances, chromatic properties are characterized as functions of their preparation conditions, such as the spray times for CNTs and the spin speeds for conductive polymers. The experimental results confirm that only the polymer-coated CNTs can satisfy all of the requirements that are required for electrodes of touch screen panels, such as the sheet resistance lower than $100{\Omega}/sq$, the visible transmittance higher than 80 %, and the yellowness smaller than 1.

Characterization of Antibacterial Activity and Synergistic Effect of Cationic Antibacterial Peptide-resin Conjugates

  • Kim, Jeong-Min;Jang, Su-Jung;Yang, Mi-Hwa;Cho, Hyeong-Jin;Lee, Keun-Hyeung
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.3928-3932
    • /
    • 2011
  • We synthesized peptide-resin conjugates (1 and 2) by immobilizing ${\beta}$-sheet antibacterial peptide and ${\alpha}$ helical antibacterial peptide on PEG-PS resin, respectively. Conjugate 1 showed considerable antibacterial activity in various conditions, whereas conjugate 2 did not exhibit antibacterial activity. The growths of various bacteria were inhibited by conjugate 1 even at lower concentrations than MIC. Conjugate 1 killed bacteria at MIC and had a potent synergistic effect with current antibacterial agents such as vancomycin and tetracycline, respectively. Overall results indicate that polymer surface modification using antibacterial ${\beta}$ sheet peptide is a powerful way to prevent microbial contamination on polymer surfaces.

옥상용 합성고분자 시트를 애용한 지붕노출 시스템 적용에 관한 연구 (A Study on Application of Exposure System using Waterproofing Sheets of Synthetic Polymer for Rooftop)

  • 이상수;김수련;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.179-183
    • /
    • 2005
  • In apply roof waterproof system using of synthetic high polymer sheet for rooftop measure physical performance (tension$\cdot$tearing ability, temperature relativity, heating stretch performance, junction performance, wind resistance test) by various test environment condition waterproof test of structure and performance of construction work aspect, present suitable form of construction work under these environment. Also, wish to improve durability of concrete structure as that examine in priority about adhesion method and joint junction method with waterproof out surface, and present new direction about roof system application of waterproofing method for rooftop.

  • PDF

Flexural bearing capacity and stiffness research on CFRP sheet strengthened existing reinforced concrete poles with corroded connectors

  • Chen, Zongping;Song, Chunmei;Li, Shengxin;Zhou, Ji
    • Structural Monitoring and Maintenance
    • /
    • 제9권1호
    • /
    • pp.29-42
    • /
    • 2022
  • In mountainous areas of China, concrete poles with connectors are widely employed in power transmission due to its convenience of manufacture and transportation. The bearing capacity of the poles must have degenerated over time, and most of the steel connectors have been corroded. Carbon fiber reinforced polymer (CFRP) offers a durable, light-weight alternative in strengthening those poles that have served for many years. In this paper, the bearing capacity and failure mechanism of CFRP sheet strengthened existing reinforced concrete poles with corrosion steel connectors were investigated. Four poles were selected to conduct flexural capacity test. Two poles were strengthened by single-layer longitudinal CFRP sheet, one pole was strengthened by double-layer longitudinal CFRP sheets and the last specimen was not strengthened. Results indicate that the failure is mainly bond failure between concrete and the external CFRP sheet, and the specimens fail in a brittle pattern. The cross-sectional strains of specimens approximately follow the plane section assumption in the early stage of loading, but the strain in the tensile zone no longer conforms to this assumption when the load approaches the failure load. Also, bearing capacity and stiffness of the strengthened specimens are much larger than those without CFRP sheet. The bearing capacity, initial stiffness and elastic-plastic stiffness of specimen strengthened by double-layer CFRP are larger than those strengthened by single-layer CFRP. Weighting the cost-effective effect, it is more economical and reasonable to strengthen with single-layer CFRP sheet. The results can provide a reference to the same type of poles for strengthening design.

방향족 도입에 의한 자외선 경화형 프리즘시트의 휘도 개전 (Improvement of Brightness in UV Curing Type Prism Sheet by Using Aromatic Groups)

  • 김동열;김형일
    • 폴리머
    • /
    • 제33권5호
    • /
    • pp.413-419
    • /
    • 2009
  • 프리즘 시트의 프리즘 층 물질의 굴절률을 증가시킬수록 휘도가 향상되어 LCD 백라이트 유닛의 효율이 향상되었다. 프리즘 층의 굴절률을 증가시키기 위해서 방향족을 포함하고 있는 고굴절 물질과 다관능성 반응물을 혼합하여 자외선 경화형 수지를 제조하였다. 9,9-Bis [4-(2-acryloyloxyethoxy)phenyl] fluorene을 반응시켜 프리즘층의 도막 굴절률을 1.58까지 증가시켰고 백라이트의 휘도를 향상시킬 수 있었다. 백라이트 유닛에 사용되는 광원에 장기간 노출될 경우 프리즘 시트에 황변현상이 발생하게 되어 휘도가 감소되므로 자외선 안정제로 hindered amine light stabilizer를 사용하여 프리즘 시트의 내황변성을 크게 향상시켰다.

배면개구형 집광시트의 자체 정렬 특성 (Self-aligning Characteristics of Optical Sheets with Apertures)

  • 박경주;김영규;최계훈;백상훈;황성기;곽진석;이종훈;권진혁;박이순
    • 한국광학회지
    • /
    • 제20권5호
    • /
    • pp.301-307
    • /
    • 2009
  • 액정표시장치의 고효율 백라이트 집광시트로 활용하기 위하여 배면 개구형 집광시트를 설계 및 분석하였다. Microlens array sheet, 피라미드 array sheet, 그리고 cone array sheet에 대해서 자체 정렬에 의한 배면 개구 형성 특성을 비교 분석한 결과, microlens array sheet가 가장 우수하였고, 다음으로 피라미드 array sheet였으며, cone array sheet가 가장 부적합하였다.

Study on Poly(3,4-ethylenedioxythiophene) Thin Film Vapour Phase-Polymerized with Iron(III)Tosylate on High Quality 3-Aminopropyltriethoxysilane Self-Assembled Monolayer

  • Choi, Sangil;Kim, Wondae;Cho, Sung Jun;Kim, Sungsoo
    • 통합자연과학논문집
    • /
    • 제5권4호
    • /
    • pp.237-240
    • /
    • 2012
  • In this study, PEDOT thin films polymerized with Iron(III)tosylate ($Fe(PTS)_3$) and grown on atomically smooth and highly dense 3-aminopropyltriethoxysilane self-assembled monolayer (APS-SAM) surfaces by VPP method have been investigated. PEDOT thin films were synthesized on APS self-assembled $SiO_2$ wafer surface at two different concentrations (20 wt% and 40 wt%) and growth time (3 and 30 minutes), and then their sheet resistance were measured and compared. PEDOT thin films grown with 20 wt% $Fe(PTS)_3$ oxidant are highly conductive when compared with the film grown with 40 wt% $Fe(PTS)_3$, as ascertained by the measured sheet resistance values down to 0.06 ${\Omega}/cm$. It clearly suggests that 20 wt% is more effective oxidant concentration for VPP than 40 wt% even though the film grown with 40 wt% oxidant has better quality than the film with 20 wt% $Fe(PTS)_3$ does.