• Title/Summary/Keyword: pole sensitivity

Search Result 55, Processing Time 0.025 seconds

Monitoring of Mythimna separata Adults by Using a Remote-sensing Sex Pheromone Trap (원격감지 성페로몬트랩을 이용한 멸강나방(Mythimna separata) 성충 예찰)

  • Jung, Jin Kyo;Seo, Bo Yoon;Cho, Jum Rae;Kim, Yong
    • Korean journal of applied entomology
    • /
    • v.52 no.4
    • /
    • pp.341-348
    • /
    • 2013
  • We desinged and evaluated a remote-sensing sex pheromone trap for real-time monitoring of Mythimna separata (Lepidoptera: Noctuidae), a migratory insect in Korea. The system consisted of a modified cone-trap with a sex pheromone lure, a sensing module based on light interruption, a signal transmission module based on code division multiple access, a main electronic board for system control, a power supply based on a solar collector, a stainless steel-pole supporting the system, and a signal collection and display system based on an internet web page. The ratio (>92%) of the actual number of insects to the signal number in the remote-sensing trap was improved by sensing only within a limited period at night on the basis of the insect's circadian rhythm, control of signal sensitivity on the basis of sensing software programming, 1-h interval for signal transmission, and adjustment of the signal transmission program. The signal occurrence pattern in the remote-sensing trap was conclusively similar (correlation coefficient, >0.98) to the actual pattern of adult occurrence in the trap. The result indicated that the remote-sensing trap based on the attraction of the sex pheromone lure for M. separata has a promising potential for practical use. Occurrence of M. separata adults was observed several times in 2011 and 2012, and the peaks were sharp.

Transfer System using Radial Electrodynamic Wheel over Conductive Track (래디얼 동전기 휠을 이용한 전도성 트랙 위에서의 이송 시스템)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.794-801
    • /
    • 2017
  • When a radial wheel is placed so as to partially overlap a conductive plate and rotated, a lift force is generated on the wheel, a thrust force along the edge, and a lateral force which tends to reduce the overlap region. When several of these wheels are combined, it is possible to realize a system in which the stability of the remaining axes is ensured, except in the traveling direction. To validate the overall characteristics of the multi-wheel system, we propose a transfer system levitated magnetically using radial electrodynamic wheels. The proposed system is floated and propelled by four wheels and arranged in a structure that allows the thrusts generated by the front and rear wheels to offset each other. The dynamic stability of the wheel and the effect of the pole number on the three-axial forces are analyzed by the finite element method. At this time, the thrust and levitation force are strongly coupled, and the only factor affecting them is the wheel rotation speed. Therefore, in order to control these two forces independently, we make use of the fact that the ratio of the thrust to the levitation force is proportional to the velocity and is independent of the size of the gap. The in-plane and out-of-plane motion control of the system is achieved by this control method and compared with the simulation results. The experimental results show that the coupled degrees of freedom can be effectively controlled by the wheel speed alone.

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF

The study of improving the performance of lower direction finding ability due to the interfered phase difference of circular array Antennas (원형배열안테나의 위상간섭에 의한 방향탐지 성능저하 개선연구)

  • Chung, Jae-Woo;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.535-539
    • /
    • 2010
  • This paper include to study DoA(Direction of Arrival) for radio collection and monitoring system. The direction finding calculated by applying the CVDF (Correlation Vector Direction Finding) algorithm for the five circular dipole antenna over V / UHF band. To improve the accuracy of direction finding by applying CVDF algorithm needs to obtain ideal phase difference each antennas. However, a circular array antenna phase difference pattern may be distorted on a specific frequency band or to particular direction. The effect of installing each array antennas circularly and the effect of the interference of center pole (located in the center of a circular array antenna mount) may make the distortion of phase pattern. If you use an active antenna instead of passive antenna to obtain good sensitivity, you would measure the more distortion. This paper propose how to change combination of antennas to measure the phase in real-time and how to use antenna beam patterns for minimizing the degradation phenomena at applying simple CVDF algorithm and increasing the direction finding capability.

  • PDF

Predictive Factors of Renal Scarring in Children with Acute Urinary Tract Infection (급성 요로감염 환아의 신장 반흔 예측요인)

  • Baik, Jun-Hyun;Park, Young-Ha;Hwang, Sung-Su;Jeon, Jung-Su;Kim, Sung-Hoon;Lee, Seong-Yong;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.245-253
    • /
    • 2003
  • Puorpose: The purpose of this study was to evaluate the usefulness of $^{99m}Tc$ DMSA scintigraphy on the dignosis of a renal scar in children with urinary tract infections. Materials and Methods: Eighty three patients were included in this study, who were diagnosed as the urinary tract infection on the basis of symptom, urinalysis and urine culture. $^{99m}Tc$ DMSA scintigraphy and voiding cystoureterography were peformed within 7days before the treatment in all patients. We classified the scintigraphic findings as follow s : 1 ; a large hypoactive upper or lower pole. 2 ; a small hypoactive area. 3 ; single defect resulting in localized deformity of the outlines. 4 ; deformed outlines in a small or normal sized kidney. 5 ; multiple defects. 6 ; diffuse hypoactive kidney without regional impairment. Follow-up scintigraphy was done at least 6 months after the initial study. When the abnormality on the initial scintigraphy was not completely resolved on the follow-up scan, the lesion was defined as containing a scar. Results: One hundred and fifteen renal units of 166 units(69.3%) showed abnormal findings on the DMSA scintigraphy. 65 units(56.5%) was diagnosed as containing renal scars on follow-up scintigraphies. Incidences of renal scar among renal units showing pattern 3, 4 and 5 on the initial scan was 75%, 78% and 78%, respectively. Whereas many of renal units showing 1, 2 and 6 pattern were recovered(65%, 76%, 50%). Sensitivity, specificity and accuracy of pattern-based DMSA scintigraphic findings on the diagnosis of renal scar was 76.9%, 85.1% and 81.9%, respectively. VUR was significantly associated with the renal scar when the initial DMSA shows unrecoverable findings(pattern 3, 4, 5). Odds ratio of the renal scar in a kidney showing unrecoverable initial scintigraphic findings was 19.1. Odds ratio in a kidney with mild or moderate-to-severe VUR was 3.5 and 14.4 respectively. Conclusion: In the urinary tract infection, renal scar was significantly developed in a kidney showing unrecoverable findings on the initial DMSA scan and VUR on voiding cystoureterography.