• Title/Summary/Keyword: polarization parameters

Search Result 323, Processing Time 0.024 seconds

Electrochemical behavior of Calcium Titanate Coated Ti-6Al-4V Substrate in Artificial Saliva

  • Lee, Byoung-Cheon;Balakrishnan, A.;Ko, Myung-Won;Choi, Je-Woo;Park, Joong-Keun;Kim, Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.18 no.1
    • /
    • pp.22-25
    • /
    • 2008
  • In this study, calcium titanate $(CaTiO_3)$ gel was prepared by mixing calcium nitrate and titanium isopropoxide in 2-methoxy-ethanol. $CaTiO_3$ gel was single-layer coated on Ti-6Al-4V using a sol-gel dip-coating technique. The coating was calcined at $750^{\circ}C$ in air by utilizing a very slow heating rate of $2^{\circ}C/min$. The crystalline phases of the coating were characterized by x-ray diffraction using a slow scan rate of $1^{\circ}/min$. The morphology of the coating was analyzed by scanning electron microscopy. The corrosion behavior of Ti-6Al-4V samples coated with $CaTiO_3$ films were tested in an artificial saliva solution by potentiodynamic polarization and were quantified by the Tafel extrapolation method. The electrochemical parameters showed a considerable increase in the corrosion resistance for the $CaTiO_3$-coated Ti-6Al-4V samples compared to bare substrates.

A semi-analytical mesh-free method for 3D free vibration analysis of bi-directional FGP circular structures subjected to temperature variation

  • Shamshirsaz, Mahnaz;Sharafi, Shahin;Rahmatian, Javad;Rahmatian, Sajad;Sepehry, Naserodin
    • Structural Engineering and Mechanics
    • /
    • v.73 no.4
    • /
    • pp.407-426
    • /
    • 2020
  • In this present paper, a semi-analytical mesh-free method is employed for the three-dimensional free vibration analysis of a bi-directional functionally graded piezoelectric circular structure. The dependent variables have been expanded by Fourier series with respect to the circumferential direction and have been discretized through radial and axial directions based on the mesh-free shape function. The current approach has a distinct advantage. The nonlinear Green-Lagrange strain is employed as the relationship between strain and displacement fields to observe thermal impacts in stiffness matrices. Nevertheless, high order terms have been neglected at the final steps of equations driving. The material properties are assumed to vary continuously in both radial and axial directions simultaneously in accordance with a power law distribution. The convergence and validation studies are conducted by comparing our proposed solution with available published results to investigate the accuracy and efficiency of our approach. After the validation study, a parametric study is undertaken to investigate the temperature effects, different types of polarization, mechanical and electric boundary conditions and geometry parameters of structures on the natural frequencies of functionally graded piezoelectric circular structures.

Calculation of $^{13}C, ^{15}N,\; and \;^{29}Si$ NMR Shielding Tensors for Selected X-Substituted Silatranes Using GIAO/CSGT-SCF

  • 김동희;이미정;오세웅
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.847-851
    • /
    • 1998
  • 13C, 15N, and 29Si NMR chemical shifts have been computed for selected X-substituted silatranes (X=Cl, F, H, CH3) using Gauge-Including Atomic Orbitals (GIAO) and Continuous Set of Gauge Transformations (CSGT) at the Hartree-Fock level of theory. The isotropic 13C chemical shifts are largely insensitive to substituent-induced structural changes. In this study, the isotropic 13C chemical shifts GIAO and CSGT calculations at the HF/6-31G and HF/6-31G* levels are sufficiently accurate to aid in experimental peak assignments. The isotropic 13C chemical shifts X-substituted silatranes at HF/6-31G* level are approximately 4 ppm different from the experimental values. In contrast, the isotropic 15N and 29Si chemical shifts and the chemical shielding tensors are quite sensitive to substituent-induced structural changes. These trends are consistent with those of the experiment. The 15N chemical shift parameters demonstrate a very clear correlation with Si-N distance, especially when we use the polarization function. Changes in anisotropy, 3a as well as in the 15N isotropic chemical shifts are due primarily to changes in the value of a.. But in case of "Si the correlations are not as clean as for the 15N chemical shift.

Assay Error for Improved Pharmacokinetic Modeling and Simulation of Vancomycin (반코마이신의 약물동태학적 모델링과 시뮬레이션의 향상을 위한 분석오차)

  • Burm, Jin Pil
    • YAKHAK HOEJI
    • /
    • v.57 no.1
    • /
    • pp.32-36
    • /
    • 2013
  • The purpose of this study was to determine the influence of assay error for improved pharmacokinetic modeling and simulation of vancomycin on the Bayesian and nonlinear least squares regression analysis in 24 Korean gastric cancer patients. Vancomycin 1.0 g was administered intravenously over 1 hr every 12 hr. Three specimens were collected at 72 hr after the first dose from all patients at the following times, at 0.5 hr before regularly scheduled infusion, at 0.5 hr and 2 hr after the end of 1 hr infusion. Serum vancomycin levels were analyzed by fluorescence polarization immunoassay technique with TDX-FLX. The standard deviation (SD) of the assay over its working range had been determined at the serum vancomycin concentrations of 0, 20, 40, 60, 80 and $120{\mu}g/ml$ in quadruplicate. The polynomial equation of vancomycin assay error was found to be SD $({\mu}g/ml)=0.0224+0.0540C+0.00173C^2$ ($R^2=0.935$). There were differences in the influence of weight with vancomycin assay error on pharmacokinetic parameters of vancomycin using the nonlinear least squares regression analysis but there were no differences on the Bayesian analysis. This polynomial equation can be used to improve the precision of fitting of pharmacokinetic models to optimize the process of model simulation both for population and for individualized pharmacokinetic models. The result suggests the improvement of dosage regimens for the better and safer care of patients receiving vancomycin.

Characteristics of silver ion-exchanged glass waveguides at 633nm and $1.5{\mu}m$ (은 이온 교환법으로 만든 유리 도자로의 633nm와 $1.5{\mu}m$에서의 특성 연구)

  • 유건호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.198-202
    • /
    • 1992
  • Silver ion-exchanged glass waveguide with its large surface index difference and shallow depth is suitable to be used for the hybrid integration of semiconductor device and glass waveguide using the semiconductor film grafting technique. We report characteristics of the planar and channel glass waveguides exchanged in the diluted silver nitrate melt in the visible and infrared spectral region. Especially, we determined the fabrication parameters for single-mode channel waveguide at 1.5.$\mu$m, an important wavelength in the optical communication. Directional couplers with several different configurations were fabricated, and their 3 dB coupling length was determined as a function of wavelenGh and polarization.

  • PDF

Comparative study on Corrosion Inhibition of Vietnam Orange Peel Essential Oil with Urotropine and Insight of Corrosion Inhibition Mechanism for Mild Steel in Hydrochloric Solution

  • Bui, Huyen T.T.;Dang, Trung-Dung;Le, Hang T.T.;Hoang, Thuy T.B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.69-81
    • /
    • 2019
  • The corrosion inhibiting mechanism of Vietnam orange peel essential oil (OPEO) for mild steel in 1 N HCl solution was investigated elaborately. Corrosion inhibition ability of OPEO was characterized by electrochemical polarization, electrochemical impedance spectroscopy (EIS), and weight loss method. In the corrosive solution, OPEO worked as a mixed inhibitor and the inhibition efficiency of OPEO increased with the increase of its concentration. High inhibition efficiencies over 90% were achieved for the concentration of 3 - 4 g/L OPEO, comparable to that of 3.5 g/L urotropine (URO), a commercial corrosion inhibitor for acid media used in industry. By using adsorption isotherm models (Langmuir, Temkin and Frumkin), thermodynamic parameters of adsorption were calculated. The obtained results indicated physical adsorption mechanism of OPEO on the steel surface. The components responsible for the corrosion inhibition activity of OPEO were not only D-limonene, but also other compounds, which contain C=O, C=C, O-H, C-O-C, -C=CH and C-H bonding groups in the molecules.

Experimental and Theoretical Studies on Corrosion Inhibition Performance of Phenanthroline for Cast Iron in Acid Solution

  • Idir, B.;Kellou-Kerkouche, F.
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.260-275
    • /
    • 2018
  • The corrosion inhibition of cast iron in 1 M HCl by Phenanthroline (Phen) was investigated using potentiodynamic polarization (PDP) curves, electrochemical impedance spectroscopy (EIS), surface analysis and theoretical calculations. It is found that Phen exhibits high inhibition activity towards the corrosive action of HCl and its adsorption obeys the Langmuir adsorption isotherm model. The results showed that inhibition efficiency increases with Phen concentration up to a maximum value of 96% at 1.4 mM, and decreases slightly with the increase in temperature. The free adsorption energy value indicates that Phen adsorbs on cast iron surface in 1 M HCl via a simultaneous physisorption and chemisorption mechanism. Scanning electron microscopy (SEM) micrographs, atomic force microscopy (AFM) and FTIR analysis confirmed the formation of a protective film on cast iron surface, resulting in the improvement of its corrosion resistance in the studied aggressive solution. Quantum chemical calculations at the DFT level were achieved to correlate electronic structure parameters of Phen molecules with their adsorption mode.

The Effect of Seawater Temperature on the Electrochemical Corrosion Behaviour of Stainless Steels and Anodized Aluminum Alloys (스테인리스강과 양극산화된 알루미늄 합금의 전기화학적 부식특성에 미치는 해수온도의 영향)

  • Chong, Sang-Ok;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.85-93
    • /
    • 2021
  • The corrosion damage of materials in marine environment mainly occurs by Cl- ions due to the breakdown of passive films. Additionally, various characteristics in seawater such as salinity, temperature, immersion time, flow rate, and biological activity also affect corrosion characteristics. In this study, the corrosion characteristics of stainless steels (STS 304 and STS 316L) and anodized aluminum alloys (AA 3003 and AA 6063) were evaluated with seawater temperature parameters. A potentiodynamic polarization experiment was conducted in a potential range of -0.25 V to 2.0 V at open circuit potential (OCP). Corrosion current density and corrosion potential were obtained through the Tafel extrapolation method to analyze changes in corrosion rate due to temperature. Corrosion behavior was evaluated by measuring weight loss before/after the experiment and also observing surface morphology through a scanning electronic microscope (SEM) and 3D microscopy. Weight loss, maximum damage depth and pitting damage increased as seawater temperature increased, and furthermore, the tendency of higher corrosion current density with an increase of temperature attributed to an increase in corrosion rate. There was lower pitting damage and lower corrosion current density for anodized aluminum alloys than for stainless steels as the temperature increased.

Corrosion Inhibition Studies on Low Carbon Steel in Hydrochloric Acid Medium Using o-Vanillin-Glutamine Schiff Base

  • Thusnavis, G. Rexin;Archana, T.V.;Palanisamy, P.
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.32-40
    • /
    • 2022
  • The o-Vanillin - Glutamine Schiff base [2-Hydroxy-3-Methoxy BenzylidineCarbomyl) -2-Butanoic Acid] was examined for low carbon steel corrosion inhibition in acid media. Weight loss studies were carried out at three different temperatures to determine the inhibition efficiency (IE). Electrochemical impedance spectroscopy revealed that the charge transfer resistance controlled the corrosion reaction and Tafel polarization indicated that the Schiff base acts as mixed mode of inhibitor. SEM images were recorded for the surface morphology of the low carbon steel surface. DFT studies revealed corrosion control mechanisms using quantum chemical parameters such as EHOMO, ELUMO, energy gap (∆E), chemical Hardness (η), chemical Softness (σ), Electronegativity (χ), and the fraction of electron transferred (∆N), which is calculated using Gaussian software 09. The gas-phase geometry was fully optimized in the Density Functional Theory (DFT/B3LYP-6-31G (d)).The DFT results are in good agreement with the experimental results. All the results proved that the Schiff Base (2-Hydroxy-3-Metoxy BenzylidineCarbomyl) -2-Butanoic is a suitable alternative for corrosion inhibition of low carbon steel in acid media.

The Synergistic Effect of 2-Chloromethylbenzimidazole and Potassium Iodide on the Corrosion behavior of Mild Steel in Hydrochloric Acid Solution

  • Zhou, Liben;Cheng, Weizhong;Wang, Deng;Li, Zhaolei;Zhou, Haijun;Guo, Weijie
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.138-147
    • /
    • 2022
  • The synergistic effect of 2-chloromethylbenzimidazole (2-CBI) and potassium iodide (KI) for mild steel in 1 M hydrochloric acid solution was investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The results showed that, with the addition of 100 ppm potassium iodide, the inhibition efficiecy (IE) of 100 ppm 2-CBI in 1 M hydrochloric acid had been improved from 91.14% to 96.15%. And synergistic parameter of 100 ppm 2-CBI with different amounts of potassium iodide is always greater than 1. The adsorption of potassium iodide combining with 100 ppm 2-CBI obeys to the Langmuir adsorption isotherm. Thermodynamic adsorption parameters, including ∆G0ads, ∆Ha and ∆Sa of the adsorption of the combinned inhibitor, as well as the Ea of the mild steel corrosion in 1 M HCl with the combinned inhibitor, were calculated.