• 제목/요약/키워드: point values

검색결과 3,176건 처리시간 0.038초

한계변형률 개념을 활용한 터널안전성 평가 (Tunnel Safety Assessment by using the Concept of the Critical Strain in the Ground)

  • 박시현;박성근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.571-576
    • /
    • 2010
  • In this study, an application method of critical strains concept for tunnels' safety by using the values of measured displacements which are obtained in the field is discussed. The aim is to: (1) study on the engineering meanings of critical strains concept by reviewing the previous researches and application examples with measured displacement values; (2) study on the engineering reasonability of critical strains concept with the view point of a tunnel engineering and a geotechnical engineering; (3) study on the features of ground deformation due to tunneling and reciprocal relation between total displacement and measured displacement; (4) evaluate a tunnel safety by using domestic measurements collected in the field; and (5) re-evaluate the control criteria which were previously used in the field, with the view point of critical strains concept. Consequently, it was confirmed that critical strains in the ground has a reasonability and a possibility of unified or common concept with the view point of a tunnel engineering.

  • PDF

천공법에 의한 잔유응력 측정방법의 개선에 관한 연구 (A study on the modified hole-drilling method for determining residual stresses)

  • 왕지석;김동철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.29-35
    • /
    • 1983
  • In general, for measuring residual stresses in plane stress state, two principal stresses {\sigma}_1 , {\sigma}_2$ and their directions .theta., should be determined. Naturally, for deciding three unknowns ${\sigma}_1, {\sigma}_2, ${\theta}$-three informations are necessary and therefore three strain gages are required for determining residual stresses at one point. In this paper, we tried to measure the residual stresses of one point with only two strain gages by drilling twice the hole of different diameters at the point and by detecting relaxation strains for each hole-drilling. We present also the formulas for determining the residual stresses from relaxation strains detected by strain gages in each hole-drilling. We carried out experiment, determining principal stresses and their directions of specimens applied specified uniform stress, and compared experimental results with the values calculated by formulas presented in this paper. The values calculated by formulas presented in this paper are always a little greater than the experimental results.

  • PDF

정밀점 기구합성시 지정위치의 변경을 이용한 허근의 실수화 방법 (Derivation of Real Values from Imaginary Roots by Altering Prescribed Positions in the Precision Point Synthesis of Mechanisms)

  • 이태영;심재경;이재길
    • 한국정밀공학회지
    • /
    • 제17권7호
    • /
    • pp.196-202
    • /
    • 2000
  • In the precision point synthesis of mechanisms, it is usually required to solve a system of polynomial equations. With the aid of efficient algorithms such as elimination, it is possible to obtain all the solutions of the equations in the complex domain. But among these solutions only real values can be used fur real mechanisms, while imaginary ones are liable to be discarded. In this article, a method is presented, which leads the imaginary solutions to real domain permitting slight alteration of prescribed positions and eventually increases the number of feasible mechanisms satisfying the desired motion approximately. Two synthesis problems of planar 4-bar path generation and spatial 7-bar motion generation are given to verify the proposed method.

  • PDF

밀폐계 측정장치를 이용한 물-노말프로판올 계의 인화점 (Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus)

  • 하동명;최용찬;이성진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.140-145
    • /
    • 2002
  • The Flash Point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of chemical materials. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the Water + n-Propanol systems were measured by using Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the laws of Raoult and van laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

파라크실렌과 에폭시수지 혼합물의 인화점에 관한 연구 (Flash Point of p-xylene and Epoxy Resins Mixtures)

  • 윤희승;강민호;하동명;정국삼
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.78-82
    • /
    • 2000
  • The flash point is an important property and hazardous index of a flammable liquid. The flash points are used by virtually all the environmental, health, and safety organizations in both government and industry to classify flammable liquids for safety and transportation regulations. The basics of all flash points behavior are concerned with the vapor pressure and explosive limits. The flash points of pure components and the mixture of solvents can be calculated with the use of the laws of Raoult, Dalton and Le Chatelier. In this paper, experimentally determined lower flash points of a p-xylene and epoxy resin system were compared with the calculated values by using Raoults law. Calculated lower flash points were in reasonable agreement with the observed values.

  • PDF

리커트 퍼지 척도에 대한 퍼지 가설검정 (Fuzzy Hypotheses Testing of Likert Fuzzy Scale)

  • 강만기;이창은;최규탁
    • 한국지능시스템학회논문지
    • /
    • 제15권5호
    • /
    • pp.533-537
    • /
    • 2005
  • 리커트 척도는 어떤 의도의 질문에 대한 동의를 수치적으로 나타내는 방법으로서 주로 5점 척도를 많이 사용하나 여러번 질문에서 응답자체가 애매성을 가지고 있다. 본 연구에서는 3점 척도의 응답의 애매성을 5점 척도의 멤버쉽 함수로 나타낸 후 한 항목의 응답의 95% 신뢰구간을 다시 멤버쉽함수로 하여 그 데이터를 퍼지가설검정하였다.

붕산처리(硼酸處理) 합판(合板)의 열판건조(熱板乾燥) 및 동적(動的) 탄성율(彈性率)에 관(關)한 연구(硏究) (Studies on Press Drying and Dynamic Elastic Modulus of Plywood Treated with Boric Acid)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권3호
    • /
    • pp.56-67
    • /
    • 1987
  • Plywoods used for construction as a decorative interior material are inflammable and can make fire accidents, causing destruction of human life and property. Therefore, it is indeed required to make fire-retardant treated plywood. In this study, 3.7mm yellow meranti plywoods were soaked in 18% boric acid solutions and tap water by hot-cold bath for 1/2, 2/2, 4/2, 6/2 hours and redrying of treated plywoods was carried out by press drying at the platen temperature of 110, 130, 160, $180^{\circ}C$ and then it was conducted to investigate solution absorption, drying rates, dynamic young's modulus. specific gravity and fire-retardant factors such as burning point, flame spread length. flame exhausted time, back side carbonized area and weight loss by treating time, treating solutions and platen temperature. The results are as follows; 1. When plywood was impregnated with the hot bath temperature of $70^{\circ}C$ for 1. 2, 4, 6 hours and the cold bath temperature of $15^{\circ}C$ for 2 hours respectively, retentions of boric acid were 1.565, l.597, 1.643, 1.709kg/$(30cm)^3$ and all of them exceeded the minimum retention [1.125kg/$(30cm)^3$] even in the shortest treatment. 2. In hot-cold bath method for 1/2 hours, the drying rates of treated plywood remarkably increased with the extension of platen temperature of 110, 130, 160, $180^{\circ}C$ and the values of boric acid treated plywood were 5.900, 10.196, 45.42, 54.958m.c%/min and the values of water treated plywood were 6.014, 12.373, 46.520, 55.730m.c%/min and drying rates of water treated plywood were faster than those of boric acid treated plywood. 3. The values of boric acid treated plywoods in dynamic young's modulus were widely higher than those of water treated plywoods. And it can be observed that there were highly significant differences for treating time between dynamic young's modulus, and the values of boric acid plywoods increased with the extension of treating time but on the contrary water treated plywoods were decreased values with prolonged time 4. It was observed that there were highly significant differences for platen temperature between dynamic young's modulus. When the values of water treated plywoods in dyna nic young's modulus were abruptly decreased according to the rise of platen temperature. boric acid treated plywoods showed rather increased values at $160^{\circ}C$ of platen temperature. And in 2- way interactions, there were also highly significant for dynamic young's modulus between treating time x treating solutions and platen temperature x treating solutions. 5. Correlation coefficients of fire-retardant factors were shown in table 5. It could be recognized that there were close correlations between the treating solutions and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, but there was no correlation between fire-retardant factors and treating time and platen temperature. 6. From table 6, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carbonized area, weight loss between treating solutions. And in 2-way interactions, there were highly significant for burning point, flame spread length, weight loss between treating time $\times$ treating solutions.

  • PDF

Estimates of invariant metrics on some pseudoconvex domains in $C^N$

  • Cho, Sang-Hyun
    • 대한수학회지
    • /
    • 제32권4호
    • /
    • pp.661-678
    • /
    • 1995
  • In this paper we will estimate from above and below the values of the Bergman, Caratheodory and Kobayashi metrics for a vector X at z, where z is any point near a given point $z_0$ in the boundary of pseudoconvex domains in $C^n$.

  • PDF

3차원 안면자동인식기의 Positioning 오차분석 (An Positioning Error Analysis of 3D Face Recognition Apparatus)

  • 곽창규;조용범;손은혜;유정희;고병희;김종원;김규곤;이의주
    • 사상체질의학회지
    • /
    • 제18권2호
    • /
    • pp.34-40
    • /
    • 2006
  • 1. Objectives We are going to develope 3D Face Recognition Apparatus to analyse the facial characteristics of the Sasangin. In the process, we should identify the recognition rate of the three dimensional position using this Apparatus. 2. Methods We took a photograph of calibrator($280{\times}400mm$) with interval of 20mm longitudinal direction of 10 times using 3D Face Recognition Apparatus. In the practice, we obtained 967 point to the exclusion of points deviating from the visual field of dual camera. And we made a comparison between measurement values and three dimensional standard values to calculate the errors. 3. Results and Conclusions In this test, the average error rate of X axis values was 0.019% and the maximum error rate of X axis values was 0.033%, the average error rate of Y axis values was 0.025% and the maximum error rate of Y axis values was 0.044%, the average error rate of Z axis values was 0.158% and the maximum error rate of Z axis values was 0.269%. This results exhibit much improvement upon the average error rate 1% and the maximum error rate 2.242% of the existing 3D Recognition Apparatus. In conclusion, we assessed that this apparatus was adaptable to abstract the facial characteristic point from three dimensional face shape in the mechanical aspects.

  • PDF

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.