• Title/Summary/Keyword: plot size

Search Result 337, Processing Time 0.025 seconds

Species Diversity of a Stratified Hornbeam Community in Kwangneung Forest (광릉산림에 있어서 서나무군집의 층에 따른 종다양성에 관한 연구)

  • 이광석;장남기
    • Asian Journal of Turfgrass Science
    • /
    • v.9 no.2
    • /
    • pp.131-136
    • /
    • 1995
  • The herb, shrub, understory and canopy strata, which arbitrarily delineated by size classes, were sampled separately. The former one were sampled by the pin-point quadrat method. And remaining three by size quadrats, diversity (H= =$\Sigma$ Pi log Pi) of of each stratum was estimated for each set of census data. Species diversity within a stratum was independent of sample plot size above a minimum cumulative area. Diversity based on plotless and plot samples could he determined by the same equation, and by pooling the data needed to estimate diversity of each stratum.

  • PDF

Estimate of Optimum Plot Size and Shape for Rape Yield Trials (유채 수량검정시험구의 크기와 모양에 대한 변이계수관계)

  • 권병선;문병탁;이용보
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.1
    • /
    • pp.51-54
    • /
    • 1978
  • 3∼6m long plot with 3-4 replications will be practical for yield trials in the early hybrid generations. The C. V. values with 9m long plot was about 6.6% in variety Yudal and 13.9% in 12m plot. These results indicate that 9-12m plot with 3-4 replications could be employed in securate yield test in the advanced generations.

  • PDF

Plot Size for Investigating Forest Community Structure(II) -Adequate Plot Area of Tree Stratum in a Mixed Forest Community at T$\v{o}$kyusan Area- (삼림군집구조 조사를 위한 조사구 크기에 관한 연구(II) -덕유산지역 혼효림군집 교목층의 적정 조사구 면적-)

  • Park, In-Hyeop;Ryu, Chang-Hee;Cho, Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.7 no.2
    • /
    • pp.187-191
    • /
    • 1994
  • A mixed forest community in Tokyusan was studied to determine the adequate plot area of tree stratum for investigating forest community structure. Nineteen nested plots were set up in the studied forest community, and species-area curve and performance curve were established. According to species-area curve, the minimum plot area where a given percentage increase in plot area produced less than the same percentage increase in number of species was 500$m^2$. The minimum plot area where a given percentage increase in plot area produced less than the half of the percentage increase in number of species was 1,000$m^2$. According to performance curve of the importance values of the major species, the minimum plot area where the importance value of the major species was distinguished from each other was 900$m^2$, and the minimum plot area was 500$m^2$ except for a big tree of Pinus densiflora distributed unexpectedly. According to performance curve of species diversity, the minimum plot area was 400$m^2$. Similarity indices between plot area above 900$m^2$ and total plot area were more than 90% and similarity indices between plot area above 400$m^2$ and total plot area were more than 85%. It may be as a conclusion that minimum plot area was generally about 500$m^2$ and in case of requiring more accuracy, minimum plot area was about 1,000$m^2$.

  • PDF

Power comparison for 3×3 split plot factorial design (3×3 분할요인모형의 검정력 비교연구)

  • Choi, Young Hun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.1
    • /
    • pp.143-152
    • /
    • 2017
  • Restriction of completely randomization within a block can be handled by a split plot factorial design splitted by several plots. $3{\times}3$ split plot factorial design with two fixed main factors and one fixed block shows that powers of the rank transformed statistic for testing whole plot factorial effect and split plot factorial effect are superior to those of the parametric statistic when existing effect size is small or the remaining effect size is relatively smaller than the testing factorial effect size. Powers of the rank transformed statistic show relatively high level for exponential and double exponential distributions, whereas powers of the parametric and rank transformed statistic maintain similar level for normal and uniform distributions. Powers of the parametric and rank transformed statistic with two fixed main factors and one random block are respectively lower than those with all fixed factors. Powers of the parametric andrank transformed statistic for testing split plot factorial effect with two fixed main factors and one random block are slightly lower than those for testing whole plot factorial effect, but powers of the rank transformed statistic show comparative advantage over those of the parametric statistic.

Plot Size for Investigating Forest Community Structure(III) -Adequate Plot Area of Shrub Stratum in a Pinus densiflora Forest at Chuwangsan Area- (삼림군집구조 조사를 위한 조사구 크기에 관한 연구(III) -주왕산지역 소나무림의 관목층 적정 조사구 면적-)

  • 박인협;문광선
    • Korean Journal of Environment and Ecology
    • /
    • v.8 no.2
    • /
    • pp.150-153
    • /
    • 1995
  • A Pinus densiflora forest in Chuwangsan was studied to determine the adequate plot area of shrub stratum for investigating forest community structure. Nineteen nested plots were set up in the studied forest, and species-area curve and performance curve were established. According to species-area curve, the minimum plot area where a given percentage increase in plot area produced less than the same percentage increase in number of species was 900$m^2$. The minimum plot area where a given percentage increase in plot area produced less than the half of the percent-age increase in number of species was 1,500$m^2$. According to performance curve of the importance values of the major species, the minimum plot area where the importance value of the major species was distinguished from each other was 1,400$m^2$. According to performance curve of species diversity, the minimum plot area was 750-1,500$m^2$. Similarity indices between plot area above 900$m^2$ and total plot area were more than 90% and similarity indices between plot area above 625$m^2$ and total plot area were more than 85%. It may be given as a conclusion that minimum plot area was about 1,500$m^2$ in case of requiring more accuracy.

  • PDF

Relationship Between Farm Land Structure and Machine Operation in Korea

  • Singh, Gajendra;Ahn, Duck-Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.129-138
    • /
    • 1993
  • The shortage of agricultural labour due to industrial growth has greatly induced the mechanization in Korean agriculture. However small and scattered land holdings have been the main constraints in the process of mechanization. This paper describes the interrelationships of farm land structure, machinery selection and machinery operation areas. The sandy silt loam irrigated paddy land having single crop a year was selected as a target areas for this study. Machine operation cost is greatly influenced by operation period, plot geometry and operation area. On the improved geometry plots, optimal machine size increases slowly with increase in operation area. Operable area increases due to increased effective machine capacity on better geometry plot. The difference between the effects of operation period and plot geometry is that in the former case, the cost reduction is caused by delay in increase of machine size, whereas in the latter case timeliness cost is reduced by increase ffective capacity. The effect of farmland consolidation is greater on small plots than that on big plots. Increasing wage rates have induced the adoption of more labor saving machinery. Bigger labor saving machines require enlargement of operation area and larger plots through improvement in farm land structure. Machine cost on poor plot geometry increases more rapidly than that on the good plot geometry and as operation area increases machine cost reduces significantly. It is concluded that the development of agricultural mechanization ion Korea will depend on the improvement in farm land structure and enlargement of operation area.

  • PDF

Machining Characteristics According to the Wheel Wear in Surface Grinding for Structural Ceramics of $Si^3 N_4$ ($Si^3 N_4$ 구조용세라믹재의 연삭가공시 숫돌마멸에 따른 가공특성)

  • 왕덕현;김원일;신경오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.9-16
    • /
    • 2003
  • In this study, the decision of dressing time for diamond wheel was analyzed by observing with acoustic emission signals and surface roughness, and also obtained the machining characteristics by weibull distribution plot for the values of bending strength. From the experimental study, it was possible to predict the time of re-dressing for the diamond grinding wheel with the analysis of acoustic emission signals and surface roughness values, and following conclusions were obtained. The root-mem-square values of acoustic emission signals were obtained low as the increased of table speed for different abrasive grain size. This is caused by the lack of grinding power which is not able to get rid of all real grinding mass of depth as the table speed is increased. The values of bending strength for ground $Si_3 N_4$ specimens were decreased for gain size of #400 than that of #60, but it was found that the surface roughness values for gain size of #60 were better than that of #400. As compared the shape parameter of weibull distribution plot for the values of bending strength, it was found that the reliability of bending strength for grain size of #60 increased than that of #400.

An Improved Method of Pore Size Distribution Analysis

  • Cho, Hyun-Woo;Ahn, Woon-Sun;Halsey, G. D.
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.2
    • /
    • pp.94-98
    • /
    • 1988
  • An improvement over the method of pore size distribution analysis has been made in this work. The improved method is based upon the idea of the micro pore analysis of Mikhail, Brunauer, and Bodor, and utilizes the V-t curve of nitrogen adsorption. Two pore models are assumed, and the deviation of the initial slope of the V-t plot is ascribed to the pore filling and to the adsorption on the wall of unfilled pores. The improved method of this work is very convenient in that the analysis starts from the small pore regions. The method of this work is however quite distinct from the similar V-t plot method proposed by Sellevold and Radjy. The proposed method is applied to a few adsorbents, and very satisfactory results are obtained. The cumulative surface area calculated by this method also agrees very well with those obtained by the BET plot or by the t-method.

Synthesis and Comparative Analysis of Crystallite Size and Lattice Strain of Pb2Ba1.7Sr0.3Ca2Cu3O10+δ Superconductor

  • Hasan, Maher Abd Ali;Jasim, Kareem Ali;Miran, Hussein Ali Jan
    • Korean Journal of Materials Research
    • /
    • v.32 no.2
    • /
    • pp.66-71
    • /
    • 2022
  • In this article, Pb2Ba1.7Sr0.3Ca2Cu3O10+δ superconductor material was synthesized using conventional solid-state reaction method. X-ray diffraction (XRD) analysis demonstrated one dominant phase 2223 and some impurities in the product powder. The strongest peaks in the XRD pattern were successfully indexed assuming a pseudo-tetragonal cell with lattice constants of a = 3.732, b = 3.733 and c = 14.75 Å for a Pb-Based compound. The crystallite size and lattice strain between the layers of the studied compound were estimated using several methods, namely the Scherrer, Williamson-Hall (W.H), size-strain plot (SSP) and Halder Wagner (H.W) approach. The values of crystallite size, calculated by Scherrer, W.H, SSP and H.W methods, were 89.4540774, 86.658638, 87.7555823 and 85.470086 Å, respectively. Moreover, the lattice strain values obtained by W.H, SSP and H.W methods were 0.0063240, 0.006325 and 0.006, respectively. It was noted that all crystallite size results are consistent; however, the best method is the size-strain plot because it gave a value of R2 approaching one. Furthermore, degree of crystallites was calculated and found to be 59.003321%. Resistivity analysis suggests zero-resistance, which is typical of superconducting materials at critical temperature. Four-probe technique was utilized to measure the critical temperature at onset Tc(onset), zero resistivity Tc(off set), and transition (width ΔT), corresponding to temperatures of 128 K, 116 K, and 12 K, respectively.

Bund Collapse in Sloping Paddy Area by a Heavy Rainfall -Case Study for Dongrim-ri in Chungbuk Province- (집중호우에 의한 경사지논의 논둑붕괴 -충북 청원군 옥산면 동림리의 사례-)

  • 김진수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.5
    • /
    • pp.55-63
    • /
    • 1996
  • The situation and cause of bund collapse in steep sloping paddy area by a heavy rainfall of Chungbuk Province were investigated by field surveys. Shapes of paddy plots are irregular and average size of them is 12.6a. Surface, groundwater and plot-to-plot irrigations are being carried out in the study plots. The type of bund collapse can be divided as follows: overflow type and inundation type. The overflow type generally occurs at the bund with slope lacking the design standard. The inundation type damages paddy plots more seriously than the overflow type. It induces continuous bund collapse from a inflow-plot to a outflow-plot and includes lots of type (inside paddy) collapse, which results in much subsoil erosion. The installation of mountain stream weir and maintenance of mountain stream are proposed to prevent the inundation type collapse.

  • PDF