• Title/Summary/Keyword: platinum foil

Search Result 10, Processing Time 0.028 seconds

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE LABIAL MARGINAL FIT OF METAL CERAMIC CROWNS MADE BY DIFFERENT TECHNIQUES (도재전장주조관의 제작방법에 따른 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구)

  • Yoon, Il-Joong;Chang, Wan-Shik;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.151-164
    • /
    • 1986
  • The purpose of this study was to evaluate the marginal fit of metal ceramic crowns made by different techniques. The techniques were metal butt margin technique, platinum foil technique, shoulder powder techniques and wax technique. The latter three techniques were for the fabrication of collarless metal ceramic crowns. Ten crowns were made of each techniques, and marginal fit was evaluated using scanning electron microscope under X200 magnification. The results were as follows. 1. The marginal fit in the descending order were wax technique shoulder powder technique, platinum foil technique and metal butt margin, before cementation, and wax technique, shoulder powder technique, metal butt margin, and platinum foil technique, after cementation. 2. The fit of collarless metal ceramic crowns was comparable to metal ceramic crowns with metal butt margins. 3. There were no statistically significant differences between marginal fit of metal ceramic crowns made by different techniques.

  • PDF

Effect of Kind and Thickness of Seed Metal on the Surface Morphology of Copper Foil (Seed 금속의 종류와 두께에 따른 구리 전착층의 표면형상에 미치는 영향)

  • Woo, Tae-Gyu;Park, Il-Song;Seol, Kyeong-Won
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.283-288
    • /
    • 2007
  • This study aimed to investigate the effects of the seed layer with copper electroplating on the surface morphology of copper foil. Three kinds of seed metal such as platinum, palladium, Pt-Pd alloy were used in this study. Electrodeposition was carried out with the constant current density of 200 $mA/cm^2$ for 68 seconds. Electrochemical experiments, in conjunction with SEM, XRD, AFM and four-point probe, were performed to characterize the morphology and mechanical characteristics of copper foil. Large particles were observed on the surface of the copper deposition layer when a copper foil was electroplated on the 130 nm thickness of Pd, Pt-Pd seed layer. However, a homogeneous surface, low resistivity was obtained when the 260 nm thickness of Pt, Pt-Pd alloy seed layer was used. The minimum value of resistivity was 2.216 ${\mu}{\Omega}-cm$ at the 260 nm thickness of Pt-Pd seed layer.

Heterogeneous Ignition of $H_2/O_2/CO_2$ Mixture Over Platinum Catalyst (수소/산소/이산화탄소 혼합기의 백금촉매반응특성 : 비균일 반응의 점화 온도)

  • Nam, Chang-Ho;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.90-96
    • /
    • 2001
  • Catalytic ignition of $H_2/O_2/CO_2$ mixtures over platinum catalyst is experimentally investigated by using microcalorimetry. For comparison, $N_2$ and Ar is also used as diluent gas. The gas mixture flows toward platinum foil heated by electric current at atmosphere pressure and ambient temperature. The ignition temperature range 350-445K according to the fuel ratio, dilution ratio and diluent gas. It increases as the fuel ratio and dilution ratio increase. $H_2/O_2$ mixture with $CO_2$ ignites at higher temperature than with other diluents by 30-50K. Several experimental evidences show the inhibition effects of $CO_2$ in $H_2-O_2$ heterogeneous reaction is considerable

  • PDF

Clinical case using The platinum foil Technique (백금박 라미네이트를 이용한 임상증례)

  • Kim, sun kyu;Shin, jun hyouk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.4-12
    • /
    • 2020
  • Recently, according to the concept of minimal invasive, there have been many opportunities for restoration treatment with porcelain laminate veneers that are less invasive and can ideally improve esthetics. Patients also visit the laminate well, and patients also want to reduce the amount of teeth cut, so the choice of the entire trimming crown is decreasing. Therefore, various techniques of laminate are required. Most dental clinicians seem to have negative images of laminates such as risk of fracture, margin pigmentation and dropout. However, this situation is due to incorrect adhesion manipulation and lack of inspection of the occlusal relationship, and there is no problem with the Porcelain Laminate Veneer itself. The purpose and scope of adaptation leading to the success of porcelain laminate veneer will be introduced.

Synthesis of Li2PtO3 Thin Film Electrode by an Electrostatic Spray Deposition Technique

  • Oh, Heung-Min;Kim, Ji-Young;Lee, Kyung-Keun;Chung, Kyung-Yoon;Kim, Kwang-Bum
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2010
  • $Li_2PtO_3$ thin film electrodes, which might be possible candidate for the cathode materials for implantable batteries, were synthesized using an electrostatic spray deposition (ESD) technique onto a platinum foil substrate. Single phase $Li_2PtO_3$with a structure similar to layered $LiCoO_2$ structure were synthesized by spraying a precursor solution of $CH_3CO_2Li2H_2O$ in ethanol onto a Pt substrate at temperatures ranging from 200 to $400^{\circ}C$ followed by annealing at above $600^{\circ}C$. Lithium carbonate was the only major phase at temperatures up to $500^{\circ}C$. The X-ray diffraction (XRD) peaks of the Pt foil substrate and lithium carbonate disappeared at temperatures >$600^{\circ}C$. The volumetric capacity of the $Li_2PtO_3$ thin film synthesized using the ESD technique was approximately 817 mAh/$cm^3$, which exceeded that of $LiCoO_2$ (711 mAh/$cm^3$).

The Effect of Hydroxy Ethyl Cellulose(HEC) on the Surface Morphology and Mechanical Characteristis of Copper Electrodeposition (구리 전해도금 시 표면형상과 기계적 특성에 미치는 HEC효과)

  • Woo, Tae-Gyu;Park, Il-Song;Lee, Hyun-Woo;Seol, Kyeong-Won
    • Korean Journal of Materials Research
    • /
    • v.16 no.11
    • /
    • pp.710-714
    • /
    • 2006
  • The purpose of this study is to identify the effect of additives and composition on copper surface morphology and mechanical characteristics by copper electrodeposition. Additives such as hydroxy ethyl cellulose(HEC), chloride ion were used in this study. Electrochemical experiments allied to SEM, XRD, AFM and four- point probe were performed to characterize the morphology and mechanical characters of copper in the presence of additives. Among various electrodeposition conditions, the minimum surface roughness of copper foil was obtained when electrodeposited at the current density of 200 mA/$cm^2$ for 68 seconds with 2 ppm of HEC. The minimum value of surface roughness(Rms) was 107.6 nm. It is copper foil is good for electromigration inhibition due to preferential crystal growth of Cu (111) deposited in the electrolyte containing chloride ions(10 ppm) and HEC(1 ppm).

Characterization of Electrochemical Ammonia Electrolysis Using a Platinum Electrode for Anodic Reaction (Pt포일 양극을 이용한 전기화학적 암모니아 수전해 특성 연구)

  • CHOI, JEONGMIN;KIM, HAKDEOK;SONG, JUHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.337-342
    • /
    • 2022
  • In this study, a water electrolysis was studied to investigate the effect of ammonia on current density and H2 gas production. A H type cell with three electrodes was used and KOH solution was used as electrolyte. The conventional platinum foil was used for working electrode, whereas nickel foam was used for counter electrode. CV experiment was performed to see the activity of ammonia oxidation reaction. In addition, CP experiment was done to examine the dependence of Faraday efficiency of hydrogen on current density and NH3 concentration. The CV result shows the 0.5M NH3 concentration required for highest current density and reliable operation. The CP result shows the increased current density leads to higher H2 generation. The higher H2 production and subsequent energy efficiency was observed for 0.5M NH3 using a Pt/13%Rh coil for a cathode as compared to those in water electrolysis.

Preparation and Reaction Studies of $Pt/Al_2O_3$ Model Catalysts

  • Kim, Chang-Min;Gabor A. Somorjai
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.4
    • /
    • pp.414-419
    • /
    • 1994
  • Surface of Pt/$Al_2O_3$ model catalyst was produced on an aluminum foil with surface area of 1 $cm^2$ The aluminum surface was oxidized under $10 ^5Torr$Torr oxygen and platinum was deposited on top of the oxide layer using a plasma evaporation source. Conversion of I-butene was performed on the model catalyst surface. Isomerization was the major reaction in I-butene conversion on the aluminum oxide layer. Addition of Pt on the aluminum oxide layer induces hydrogenation of I-butene. Selectivity for the hydrogenation increases as the amount of Pt on alumina increases.

  • PDF

Fabrication of Electro-active Polymer Actuator Based on Transparent Graphene Electrode

  • Park, Yunjae;Choi, Hyonkwang;Im, Kihong;Kim, Seonpil;Jeon, Minhyon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.386.1-386.1
    • /
    • 2014
  • The ionic polymer-metal composite (IPMC), a type of electro-active polymer material, has received enormous interest in various fields such as robotics, medical sensors, artificial muscles because it has many advantages of flexibility, light weight, high displacement, and low voltage activation, compare to traditional mechanical actuators. Mostly noble metal materials such as gold or platinum were used to form the electrode of an IPMC by using electroless plating process. Furthermore, carbon-based materials, which are carbon nanotube (CNT) and reduced graphene-CNT composite, were used to alter the electrode of IPMC. To form the electrode of IPMC, we employ the synthesized graphene on copper foil by chemical vapor deposition method and use the transfer process by using a support of PET/silicone film. The properties of graphene were evaluated by Raman spectroscopy, UV/Vis spectroscopy, and 4-point probe. The structure and surface of IPMC were analyzed via field emission scanning electron microscope. The fabricated IPMC performance such as displacement and operating frequency was measured in underwater.

  • PDF

A STUDY ON THE COLOR CHANCE OF CERAMIC BY Pd-Ag ALLOY AND MECHANISM (팔라디움-은합금에 의한 도재의 색조변화 및 변색작용에 관한 연구)

  • Youn, Soo-Sun;Lee, Sun-Hyung;Yang, Jae-Ho;Chong, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.123-141
    • /
    • 1989
  • The purpose of this study was to investigate the tendency of color change of ceramic, and its mechanism un der the influence of Pd-Ag alloy. The specimens were made by firing porcelain on tile metal plates cast with Au-Pt alloy, Pd-Cu alloy and Pd-Ag alloy. In the case of Pd-Ag alloy, specimens were fired under three different conditions as follows, 1) without protection, 2) protection with ceramic metal conditioner, 3) protection with carbon block. For the specimens of element analysis, a barrier was constructed with platinum foil between metal plate and ceramic. Color change was measured with colorimeter and elemental changes in ceramic were calculated with DC argon plasma emission spectrophotometer. The results were as follows : 1. Color change of ceramic by Pd-Ag alloy was negligible in hue, but decreased in value and increased in chroma (yellow discoloration). 2. Color change of ceramic by Pd-Ag alloy was appeared through vapor transport mechanism. 3. As the protection method for the color change of ceramic by Pd-Ag alloy, application of ceramic metal conditioner was superior to utilization of carbon block.

  • PDF