• Title/Summary/Keyword: platinum

Search Result 1,167, Processing Time 0.031 seconds

Clinical Study on Laryngo - Microscopic Surgery For Vocal Nodules and Polyps (후두결절 및 폴립의 후두미세 수술에 관한 임상연구)

  • 문영일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.11.2-11
    • /
    • 1983
  • Vocal nodules and polyps are much more frequent in singers, public speakers, teachers and actors. Voice trauma and voice misuse, at times associated with mild inflammatory reaction, appear to be important in their etiology. It is generally agreed that vocal cord nodules and polyps are inflammatory in nature and they arise in the subepithelial layer of loose connective tissue of the vocal cord. Since the junction of anterior and middle thirds of the membranous cord and has the greatest amplitude of vibration. This is the site of predilection for vocal cord nodules. The author performed laryngomicrosurgery for 70 cases of vocal nodules and polyps at Ewha Womans University Hospital during the period of 5 years. The result obtained were as follows ; 1) Surgical excision is not necessarily the best approach because vocal nodules in the early stages will resolve with the simplest voice therapy. 2) In children, surgery is rarely indicated because most nodules in children regress during adolescence. 3) For patients who use their voices professionally, voice therapy is indicated for three months. 4) If after three month of conservative treatment the cord lesion does not improve and the patient it still dissatisfied with his voice, laryngomicrosurgery can then be considered. 5) The small cuffed endotracheal tube in the interarytenoid space helps to keep the cords immobile and in an abducted position. 6) Removal of the nodule shoule be started by gentle retraction posteriorly and as soon as a tear appears anterior to the nodule. 7) On occasion it is preferable to start the dissection with a siccle knife while the nodule is held on the stretch. 8) Voice rest should be maintained for a week following which the free edges of the cords are usually healed.

  • PDF

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Electrofusion of Yeast Cells and Their Genetic Analysis Using RAPD-PCR (효모세포의 전기융합 및 융합세포의 RAPD-PCR을 이용한 유전적 분석)

  • Kim, Seung;Kim, Jae-Sung;Sapkota, Kumar;Park, In-Sung;Cho, Moon-Gu;Park, Yeal;Chun, Hong-Sung;Choi, Bong-Suk;Park, Se-Eun;Choi, Han-Suk;Kim, Myung-Kon;Kim, Sung-Jun
    • Applied Biological Chemistry
    • /
    • v.49 no.3
    • /
    • pp.186-191
    • /
    • 2006
  • In the present study, an attempt has been made to produce hybrid yeast strains of different useful and dominant characteristics. The hybrid yeast strains were produced by electrofusion and their genetic analysis were performed by RAPD-PCR (random amplified polymorphic DNA-polymerase chain reaction). The protoplast of Saccharomyces cerevisiae KCTC 7904 and Zygosaccharomyces rouxii KCTC 7966 were obtained above 92% when treated with lyticase at $30^{\circ}C$ for $60{\sim}90$ min after the pretreatment of $1{\sim}2%$ 2-mercaptoethanol at $30^{\circ}C$ for $15{\sim}20$ min. The fusant was produced from paired protoplast stage under the electric pulse at high frequency conditions (1.5 MHz/50 pV, 615 $V/256\;{\mu}sec$) within glass-platinum made electrofusion chamber. Changes in RAPD patterns in mother cells and hybrid cells proved that the fusant contains two types of yeast gene originated from its parent. Furthermore, fermentation characters exhibits by the fusant cell confirmed its genetic changes. These results suggest that genetically stable hybrid yeast strains of economic importance can be produced by electrofusion technique and these electrofused yeast cells have an enormous impact in biotechnology and biomedicine.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Induction Chemotherapy and Radiotherapy in Locally Advanced Non-Small Cell Lung Cancer (NSCLC) (국소 진행된 비소세포성 폐암에서 유도 화학요법 및 방사선치료)

  • Yun, Sang-Mo;Kim, Jae-Cheol;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.195-202
    • /
    • 1999
  • Purpose : We peformed this study to evaluate the prognostic factors and the effect of induction chemotherapy in locally advanced non-small cell lung cancer (NSCLC). Materials and Methods : A retrospective analysis was done for 130 patients with locally advanced NSCLC treated with curative radiotherapy alone or induction chemo-radiotherapy from January 1986 to October 1996. Eighty-five patients were treated with radiotherapy alone, forty-five with induction chemotherapy and radiotherapy. Age, sex, performance status, histopathologic type, and stage were evenly distributed in both groups. The patients were treated with 6 MV or 10 MV X-ray. Conventional fractionation with daily fraction size 1$.8\~2.0$ Gy was done. Of the patients, 129 patients received total dose above 59.6 Gy ($56\~66$ Gy, median 60 Gy). Induction chemotherapy regimen were CAP (Cyclo-phosphamide, Adriamycin, Cisplatin) in 6 patients, MVP (Mitomycin, Vinblastine, Cisplatin) in 9 patients, MIC (Mitomycin, Ifosfamide Cisplatin) in 13 patients, and EP (Etoposide, Cisplatin) in 17 patients. Chemotherapy was done in $2\~5$ cycles (median 2). Results : Overall 1-, 2-, and 3-year survival rate (YSR) for all patients were $41.5\%,{\;}13.7\%,{\;}and{\;}7\%$, respectively (median survival time 11 months). According to treatment modality, median survival time, overall 1-, 2-, and 3-YSR were 9 months, $32.9\%,{\;}10.\5%,{\;}6\%$ for radiotherapy alone group, and 14 months, $57.8\%,{\;}20\%,{\;}7.6\%$ for induction chemotherapy group, respectively (f=0.0005). Complete response (CR) to overall treatments was $25\%$ (21/84) in radiotherapy alone and $40.5\%$ (17/42) in induction chemotherapy group (p=0.09). The Prognostic factors affecting overall survival were hemoglobin level (p=0.04), NSE (neuron-specific enolase) level (p=0.004), and respense to overall treatment(p=0.004). According to treatment modalities, NSE (neuron-specific enolase) (p=0.006) and response to overall treatment (p=0.003) were associated with overall survival in radiotherapy alone group, and response to overall treatment (p=0.007) in induction chemotherapy group. The failure Pattern analysis revealed no significant difference between treatment modalities. But, in patients with CR to overall treatment, distant metastasis were found in 11/19 patients with radiotherapy alone, and 3/13 patients with induction chemotherapy and radiotherapy (p=0.07). Locoregional failure patterns were not different between two groups (10/19 vs 6/13). Conclusion : Induction chemotherapy and radiotherapy achieved increased 2YSR compared to radiotherapy alone, At least in CR patients, there was decreased tendency in distant metastasis with induction chemotherapy. But, locoregional failures and long-term survival were not improved. Thus, there is need of more effort to increasing local control and further decreasing distant metastasis.

  • PDF

The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer (식도암 치료에 있어 관내근접치료의 역할)

  • Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil;Chung Eun Ji;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.331-338
    • /
    • 1995
  • Purpose : To evaluate our clinical experience with the combination of teletherapy and intraluminal brachytherapy in patients with unresectable or inoperable esophageal cancers. Materials and Methods : From Nov 1989 to Mar 1993, twenty patients with esophageal cancer were treated with radical radiotherapy and intraluminal brachytherapy at Yonsei Cancer Center. All patients had squamous histolgy and stage distribution was as follows: stage II, 4($20{\%}$)patients; III, 15 ($75{\%}$)patients; IV, 1($5{\%}$)patients. A dose of S-12Gy/1-3weeks with intraluminal brachytherapy (3-5Gy/fraction) to 5mm from the outside of the esophageal tube using high dose rate Iridium-192 remotely afterloading brachytherapy machine was given 2 weeks after a total dose of 59-64Gy with external radiotherapy. Induction chemotherapy using cisplatin and 5-FU was performed in 13 patients with median 3 cycles(1-6 cycles), Response rate, local control rate, survival and complications were analysed retrospectively. Results : Two-year overall survival rate and median survival were $15.8{\%}$ and 13.5 months. Response rates were as follows complete remission(CR) 5($25{\%}$): partial remission a(PRa) 7($35{\%}$): partial remission b(PRb) 7($35{\%}$), no response(NR) 1($5{\%}$). Patterns of failure were as follows; local failure 13($65{\%}$), local and distant failure 3($15{\%}$), distant failure 0($0{\%}$). Ultimate local control rate was $20{\%}$. Treatment related complications included esophageal ulcer in two patients and esophageal stricture in one. Conclusion : Though poor local conrol rate, median survival was improved as compared with previous results of radiation therapy alone(8months) and chemoradiation combined treatment(11 months) in Yonsei Cancer Center High-dose-rate intraluminal brachytherapy following external irradiation is an effective treatment modality with acceptable toxicity in esophageal cancer.

  • PDF