• 제목/요약/키워드: plastic deformation capacity

검색결과 187건 처리시간 0.024초

Experimental assessment on flexural behavior of demountable steel-UHPC composite slabs with a novel NPR steel plate

  • Jin-Ben Gu;Jun-Yan Wang;Yi Tao;Qing-Xuan Shi
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.381-392
    • /
    • 2023
  • This study experimentally investigates the flexural behavior of steel-UHPC composite slabs composed of an innovative negative Poisson's ratio (NPR) steel plate and Ultra High Performance Concrete (UHPC) slab connected via demountable high-strength bolt shear connectors. Eight demountable composite slab specimens were fabricated and tested under traditional four-point bending method. The effects of loading histories (positive and negative bending moment), types of steel plate (NPR steel plate and Q355 steel plate) and spacings of high-strength bolts (150 mm, 200 mm and 250 mm) on the flexural behavior of demountable composite slab, including failure mode, load-deflection curve, interface relative slip, crack width and sectional strain distribution, were evaluated. The results revealed that under positive bending moment, the failure mode of composite slabs employing NPR steel plate was distinct from that with Q355 steel plate, which exhibited that part of high-strength bolts was cut off, part of pre-embedded padded extension nuts was pulled out, and UHPC collapsed due to instantaneous instability and etc. Besides, under the same spacing of high-strength bolts, NPR steel plate availably delayed and restrained the relative slip between steel plate and UHPC plate, thus significantly enhanced the cooperative deformation capacity, flexural stiffness and load capacity for composite slabs further. While under negative bending moment, NPR steel plate effectively improved the flexural capacity and deformation characteristics of composite slabs, but it has no obvious effect on the initial flexural stiffness of composite slabs. Meanwhile, the excellent crack-width control ability for UHPC endowed composite members with better durability. Furthermore, according to the sectional strain distribution analysis, due to the negative Poisson's ratio effect and high yield strength of NPR steel plate, the tensile strain between NPR steel plate and UHPC layer held strain compatibility during the whole loading process, and the magnitude of upward movement for sectional plastic neutral axis could be ignored with the increase of positive bending moment.

연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요 (Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions)

  • 서수연;이리형
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동 (Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load)

  • 강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.387-395
    • /
    • 2000
  • 본 연구는 콘크리트충전 각형강관(CFT) 기둥의 강도와 변형능력의 평가 및 내진성능에 대한 기초 자료의 제시를 목적으로 한다. 실험체는 초고층 건물의 최하단기둥의 응력분포를 가정하여 켄틸레버형 기둥으로 하고, 총 18개의 실험체가 일정 축력과 반복 횡하중 하에서 실험되었다. 본 실험에 적용된 주요변수는 강관의 폭/두께 비, 세장비 (LO/D), 그리고 축력비이다. 각 변수가 기둥의 강도, 변형능력, 그리고 에너지 흡수능력에 미치는 영향이 기술되었고, 각국 규준식과 실험결과를 비교하였다. 분석결과, 피복형 한국강구조학회 규준은 합성 단면적과 탄성계수를 AIJ와 AISC-LRFD 수준으로 수정한다면, 충전형에도 적용가능 할 것으로 판단된다. 마지막으로, 구속효과를 고려하여 단면의 소성해석을 통하여 구한 B. Kato의 CFT 기둥의 휨내력 제안식은 실험결과와 좋은 대응을 나타내고 있다.

  • PDF

Research on hysteretic characteristics of EBIMFCW under different axial compression ratios

  • Li, Sheng-cai;Lin, Qiang
    • Earthquakes and Structures
    • /
    • 제22권5호
    • /
    • pp.461-473
    • /
    • 2022
  • Energy-saving block and invisible multiribbed frame composite wall (EBIMFCW) is an important shear wall, which is composed of energy-saving blocks, steel bars and concrete. This paper conducted seismic performance tests on six 1/2-scale EBIMFCW specimens, analyzed their failure process under horizontal reciprocating load, and studied the effect of axial compression ratio on the wall's hysteresis curve and skeleton curve, ductility, energy dissipation capacity, stiffness degradation, bearing capacity degradation. A formula for calculating the peak bearing capacity of such walls was proposed. Results showed that the EBIMFCW had experienced a long time deformation from cracking to failure and exhibited signs of failure. The three seismic fortification lines of the energy-saving block, internal multiribbed frame, and outer multiribbed frame sequentially played important roles. With the increase in axial compression ratio, the peak bearing capacity and ductility of the wall increased, whereas the initial stiffness decreased. The change in axial compression ratio had a small effect on the energy dissipation capacity of the wall. In the early stage of loading, the influence of axial compression ratio on wall stiffness and strength degradation was unremarkable. In the later stage of loading, the stiffness and strength degradation of walls with high axial compression ratio were low. The displacement ductility coefficients of the wall under vertical pressure were more than 3.0 indicating that this wall type has good deformation ability. The limit values of elastic displacement angle under weak earthquake and elastic-plastic displacement angle under strong earthquake of the EBIMFCW were1/800 and 1/80, respectively.

Experimental investigation on the seismic behavior of reinforced concrete column-steel beam subassemblies

  • Xiong, Liquan;Men, Jinjie;Ren, Ruyue;Lei, Mengke
    • Steel and Composite Structures
    • /
    • 제28권4호
    • /
    • pp.471-482
    • /
    • 2018
  • The composite reinforced concrete and steel (RCS) structural systems have larger structural lateral stiffness, higher inherent structural damping, and faster construction speed than either traditional reinforcement concrete or steel structures. In this paper, four RCS subassemblies with or without the RC slab designed following a strong column-weak beam philosophy were constructed and tested under reversed-cyclic loading. Parameters including the width of slab and composite effect of the RC slab and beam were explored. The test results showed that all specimens performed in a ductile manner with plastic hinges formed in the beam ends near the column faces. The seismic responses of composite connections are influenced significantly by different width of slabs. Compared with that of the steel beam without the RC slab, it was found that the load carrying capacity of composite connections with the RC slab increased by 30% on average, and strength degradation, energy dissipation also had better performance, while the ductility of that were almost the same. Furthermore, the contribution of connection deformation to the overall specimen displacement was analyzed and compared. It decreased approximately 10% due to the coupling effect in the columns and beams with the RC slab. Based on the test result, some suggestions are presented for the design of composite RCS joints.

RC기둥의 내진성능에 미치는 겹침 이음상세의 영향 (Effects of Lap Splice Details on Seismic Performance of RC Columns)

  • 김철구;박홍근;김태완;엄태성
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.351-360
    • /
    • 2016
  • In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length($40d_b$ and $50d_b$) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.

비탄성 국부좌굴을 고려한 철골 모멘트 접합부의 회전능력에 대한 변수 연구 (Evaluation of Rotation Capacity of Steel Moment Connections ConsideringInelastic Local Buckling - Parametric Studies)

  • 이경구
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.625-632
    • /
    • 2008
  • 동반논문(모델개발)에서는 특별철골모멘트골조의 강접합 보-기둥 접합부의 회전능력을 예측하기 위한 해석모델을 제안하였다. 본 논문에서는 접합부 회전능력 기준으로 두 개의 극한상태를 고려하였다. 첫째, 보 단면의 국부좌굴로 인해 공칭소성강도까지 강도저하가 발생하였을 때를 회전능력으로 보는 강도저하 극한상태를 고려하였다. 둘째, 큰 진폭의 변형이 몇 번 반복 후에 좌굴된 플랜지에서 소성변형률 축적으로 야기 되는 저주기 피로 파단을 극한상태로 고려하였다. 두 극한상태까지 제안한 모델을 이용하여 단조증가하중 및 반복하중하에 일련의 해석을 수행하였다. 실무설계에서 사용되는 범위안의 다양한 H-형강 보를 모델링한 후, 플랜지 및 웨브 폭-두께비와 같은 보 단면의 기하학적 변수가 WUF-W 접합부의 회전능력과 저주기 피로수명에 미치는 영향을 관찰하였다.

철근콘크리트 교각의 성능보장설계를 위한 휨 초과강도 (Flexural Overstrength of Reinforced Concrete Bridge Columns for Capacity Design)

  • 이재훈;고성현;최진호
    • 한국지진공학회논문집
    • /
    • 제10권5호
    • /
    • pp.85-97
    • /
    • 2006
  • 성능보장설계는 교각이 완전한 소성회전성능을 발휘할 때까지 다른 구조요소들과 교각 자체가 취성파괴 되지 않도록 설계하여 교량 전체 시스템의 연성파괴를 보장하기 위한 것으로서, 현행 도로교설계기준에는 명시적으로 규정되어 있지 않으나 대부분의 외국 교량내진설계기준에 채택되어 있다. 성능보장설계에서는 철근콘크리트 교각의 휨 초과강도를 구하고 이를 변환한 전단력을 교각, 기초, 말뚝에 작용하는 횡하중 설계전단력으로 결정하여 교각의 전단설계, 기초설계, 말뚝설계를 수행하도록 규정한다. 이 때 교각의 최대 소성모멘트를 결정하는 방법은 설계기준별로 각기 다른데, 이는 각 국의 재료 시공환경이 다르기 때문이다. 본 연구에서는 국내에서 사용하는 철근의 인장강도 측정치 3,407개와 콘크리트 압축강도 측정치 5,405개의 분석을 통하여 재료 초과강도계수를 제안하였고, 이를 적용하여 휨 초과강도를 결정하는 방법을 제시하였으며, 1,500개의 교각단면에 대한 모멘트-곡률 해석을 수행한 후 통계분석을 통하여 우리나라 실정에 적합한 초과강도계수를 제안하였다.

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador;Oh, Sang-Hoon;Shin, Seung-Hoon
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1107-1124
    • /
    • 2018
  • The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

Energy dissipation of steel-polymer composite beam-column connector

  • Wang, Yun-Che;Ko, Chih-Chin
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1161-1176
    • /
    • 2015
  • The connection between a column and a beam is of particular importance to ensure the safety of civil engineering structures, such as high-rise buildings and bridges. While the connector must bear sufficient force for load transmission, increase of its ductility, toughness and damping may greatly enhance the overall safety of the structures. In this work, a composite beam-column connector is proposed and analyzed with the finite element method, including effects of elasticity, linear viscoelasticity, plasticity, as well as geometric nonlinearity. The composite connector consists of three parts: (1) soft steel; (2) polymer; and (3) conventional steel to be connected to beam and column. It is found that even in the linear range, the energy dissipation capacity of the composite connector is largely enhanced by the polymer material. Since the soft steel exhibits low yield stress and high ductility, hence under large deformation the soft steel has the plastic deformation to give rise to unique energy dissipation. With suitable geometric design, the connector may be tuned to exhibit different strengths and energy dissipation capabilities for real-world applications.