DOI QR코드

DOI QR Code

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador (Department of Architectural Engineering, Pusan National University) ;
  • Oh, Sang-Hoon (Department of Architectural Engineering, Pusan National University) ;
  • Shin, Seung-Hoon (Department of Architectural Engineering, Pusan National University)
  • Received : 2017.12.14
  • Accepted : 2018.04.26
  • Published : 2018.11.30

Abstract

The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

Keywords

Acknowledgement

Supported by : Pusan National University

References

  1. ACI Committee, American Concrete Institute, & International Organization for Standardization. (2008). Building code requirements for structural concrete (ACI 318-08) and commentary. Farmington Hills: American Concrete Institute.
  2. Akiyama, H. (1985). Earthquake-resistant limit-state design for buildings. Tokyo: Univ of Tokyo Pr.
  3. Bagheri, B., Choi, K. Y., Oh, S. H., & Ryu, H. S. (2016). Shaking table test for evaluating the seismic response characteristics of concentrically braced steel structure with and without hysteretic dampers. International Journal of Steel Structures, 16(1), 23-39. https://doi.org/10.1007/s13296-016-3003-2
  4. Bagheri, B., & Oh, S. H. (2018). Seismic design of coupled shear wall building linked by hysteretic dampers using energy based seismic design. International Journal of Steel Structures, 18(1), 225-253. https://doi.org/10.1007/s13296-018-0318-1
  5. Banting, B. R., & El-Dakhakhni, W. W. (2012). Force-and displacement-based seismic performance parameters for reinforced masonry structural walls with boundary elements. Journal of Structural Engineering, 138(12), 1477-1491. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000572
  6. Benavent-Climent, A. (2011). An energy-based method for seismic retrofit of existing frames using hysteretic dampers. Soil Dynamics and Earthquake Engineering, 31(10), 1385-1396. https://doi.org/10.1016/j.soildyn.2011.05.015
  7. Bertero, V. V. (1980). Seismic behaviour of RC wall structural systems. In Proceedings of the 7th WCEE.
  8. Bertero, V. V., & Uang, C. M. (1992). Issues and future directions in the use of an energy approach for the seismic-resistant of design structures. In P. Fajfar & H. Krawinkler (Eds.), Nonlinear seismic analysis and design of reinforced concrete buildings (pp. 3-22). Amsterdam: Elsevier Applied Science.
  9. Chung, H. S., Moon, B. W., Lee, S. K., Park, J. H., & Min, K. W. (2009). Seismic performance of friction dampers using flexure of RC shear wall system. The Structural Design of Tall and Special Buildings, 18(7), 807-822. https://doi.org/10.1002/tal.524
  10. Harries, K. A., Gong, B., & Shahrooz, B. M. (2000). Behavior and design of reinforced concrete, steel, and steel-concrete coupling beams. Earthquake Spectra, 16(4), 775-799. https://doi.org/10.1193/1.1586139
  11. Harries, K. A., Shahrooz, B. M., Brienen, P., Fortney, P. J., & Rassati, G. A. (2006). Performance-based design of coupled wall systems. In Proceedings of the 5th international conference on composite construction, South Africa (pp. 686-697).
  12. Housner, G. W. (1956). Limit design of structures to resist earthquake. In Proceedings of 1st WCEE (pp. 5-1).
  13. Kim, H. J., Choi, K. S., Oh, S. H., & Kang, C. H. (2012). Dissipative coupling beams used for RC shear walls systems. 15WCEE, Lisboa, Portugal, September.
  14. Kurama, Y. C., & Shen, Q. (2004). Posttensioned hybrid coupled walls under lateral loads. Journal of Structural Engineering, 130(2), 297-309. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(297)
  15. Mao, C. X., Wang, Z. Y., Zhang, L. Q., Li, H., & Ou, J. P. (2012). Seismic performance of RC frame-shear wall structure with novel shape memory alloy dampers in coupling beams. In Proceedings of 15th world conference on earthquake engineering.
  16. Oh, S. H., Choi, K. Y., Kim, H. J., & Kang, C. H. (2012). Experimental validation on dynamic response of RC shear wall systems coupled with hybrid energy dissipative devices. 15WCEE, Lisbon, Portugal, Paper-ID, 1422, 24-28.
  17. Oh, S. H., & Jeon, J. S. (2014). A study on optimum distribution of story shear force coefficient for seismic design of multi-story structure. International Journal of High-Rise Building, 2, 121-145.
  18. Oh, S. H., & Shin, S. H. (2017). A proposal for a seismic design process for a passive control structural system based on the energy equilibrium equation. International Journal of Steel Structure, 17(4), 1-32. https://doi.org/10.1007/s13296-014-0172-8
  19. Paulay, T., & Binney, J. R. (1974). Diagonally reinforced coupling beams of shear walls. Special Publication, 42, 579-598.
  20. Paulay, T., & Priestley, M. N. (1992). Seismic design of reinforced concrete and masonry buildings. New York: Wiley.
  21. Paulay, T., & Santhakumar, A. R. (1976). Ductile behavior of coupled shear walls. Journal of the Structural Division, 102(1), 93-108.
  22. Rosmon, R. (1964). Approximate analysis of shear walls subject to lateral loads. In Journal proceedings (Vol. 61, No. 6, pp. 717-734).
  23. Smith, B. S., Coull, A., & Stafford-Smith, B. S. (1991). Tall building structures: analysis and design (Vol. 5). New York: Wiley.
  24. Subedi, N. K. (1991). RC-coupled shear wall structures. I: Analysis of coupling beams. Journal of Structural Engineering, 117(3), 667-680. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:3(667)

Cited by

  1. New optimum distribution of lateral strength of shear-type buildings for uniform damage vol.76, pp.3, 2018, https://doi.org/10.12989/sem.2020.76.3.279
  2. Effect of Torsion on Seismic Response of Single-Story Structures: an Energy-Based Design Approach (EBD) vol.21, pp.3, 2021, https://doi.org/10.1007/s13296-021-00475-0