• Title/Summary/Keyword: plasma monitoring

Search Result 353, Processing Time 0.029 seconds

Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System

  • Plato, N.;Bigert, C.;Larsson, B.M.;Alderling, M.;Svartengren, M.;Gustavsson, P.
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.377-383
    • /
    • 2019
  • Objectives: Exposure to fine particles in urban air has been associated with a number of negative health effects. High levels of fine particles have been detected at underground stations in big cities. We investigated the exposure conditions in four occupational groups in the Stockholm underground train system to identify high-exposed groups and study variations in exposure. Methods: $PM_1$ and $PM_{2.5}$ were measured during three full work shifts on 44 underground workers. Fluctuations in exposure were monitored by a real-time particle monitoring instrument, pDR, DataRAM. Qualitative analysis of particle content was performed using inductively coupled plasma mass spectrometry. Nitrogen dioxide was measured using passive monitors. Results: For all underground workers, the geometric mean (GM) of $PM_1$ was $18{\mu}g/m^3$ and of $PM_{2.5}$ was $37{\mu}g/m^3$. The particle exposure was highest for cleaners/platform workers, and the GM of $PM_1$ was $31.6{\mu}g/m^3$ [geometric standard deviation (GSD), 1.6] and of $PM_{2.5}$ was $76.5{\mu}g/m^3$ (GSD, 1.3); the particle exposure was lowest for ticket sellers, and the GM of $PM_1$ was $4.9{\mu}g/m^3$ (GSD, 2.1) and of $PM_{2.5}$ was $9.3{\mu}g/m^3$ (GSD, 1.5). The $PM_1$ and $PM_{2.5}$ levels were five times higher in the underground system than at the street level, and the particles in the underground had high iron content. The train driver's nitrogen dioxide exposure level was $64.1{\mu}g/m^3$ (GSD, 1.5). Conclusions: Cleaners and other platform workers were statistically significantly more exposed to particles than train drivers or ticket sellers. Particle concentrations ($PM_{2.5}$) in the Stockholm underground system were within the same range as in the New York underground system but were much lower than in several older underground systems around the world.

Exposure Assessment of Heavy Metals Migrated from Glassware on the Korean Market (국내 유통 식품용 유리제의 중금속 노출 평가)

  • Kim, Eunbee;Hwang, Joung Boon;Lee, Jung Eun;Choi, Jae Chun;Park, Se-Jong;Lee, Jong Kwon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2022
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), and barium (Ba) from glassware into a food simulant and to evaluate the exposure of each element. The test articles were glassware, including tableware, pots, and other containers. Pb, Cd, and Ba were analysed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The analytical performance of the method was validated in terms of its linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. The monitoring was performed for 110 samples such as glass cups, containers, pots, and bottles. a food simulant. Migration test was conducted at 25? for 24 hours in a dark place using 4% acetic acid as a food simulant. Based on the data; exposure assessment was carried out to compare the estimated daily intake (EDI) to the human safety criteria. The risk levels of Pb and Ba determined in this study were approximately 1.9% and 0.3% of the provisional tolerable weekly intake (PTWI) and tolerable daily intake (TDI) value, respectively, thereby indicating a low exposure to the population.

Monitoring of some heavy metals in oriental animality medicines (동물성 생약에 함유되어 있는 몇 가지 중금속에 대한 실태 조사)

  • Baek, Sunyoung;Chung, Jaeyoen;Lee, Jihye;Park, Kyungsu;Kang, Inho;Kang, Sinjung;Kim, Yunje
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-209
    • /
    • 2009
  • Four heavy metals (Pb, Cd, As, and Hg) in 38 species (total 325 samples) of oriental animality medicines were monitored by inductively coupled plasma-mass spectrometry (ICP-MS) and automatic mercury analyzer (AMA). The detected concentration range of Pb, Cd, As was presented as $0.02{\mu}gkg^{-1}$ $(D.L){\sim}11.29mgkg^{-1}$, $0.01{\mu}gkg^{-1}$ $(D.L){\sim}2.50 mgkg^{-1}$, $0.12{\mu}gkg^{-1}$ $(D.L){\sim}5.27mgkg^{-1}$, respectively. In case of Hg, it the concentration range was $0.01{\sim}77.11mgkg^{-1}$ except one sample which exceeded detection limit. In all samples of Amydae Carapax and Gallnut, it was not detected over the maximum residue limits of metals. Pb is in charge of the greatest portion of contamination in 22 species of animality medicines, and in case of Hg, 54.46% of total samples were over the maximum residue limits. Therefore, environmental levels of Pb and Hg are needed to continue the researches and the studies for tracking pollution source are required.

Monitoring of Heavy Metals in Fishes in Korea -As, Cd, Cu. Pb, Mn, Zn, Total Hg - (유통 중인 어류의 중금속 모니터링 - 비소, 카드뮴, 구리, 납, 망간, 아연, 총수은 -)

  • Kim, Hee-Yun;Kim, Seo-Young;Lee, Jin-Ha;Jang, Young-Mi;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Kim, Jin-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.353-359
    • /
    • 2007
  • This survey was carried out to estimate the heavy metal contents of fishes (531 ocean fishes and 80 freshwater fishes) sold in and around Korea from April to October in 2006 . The contents of arsenic (As), cadmium (Cd), copper (Cu), lead (Pb), manganese (Mn), zinc (Zn) and mercury (Hg) were estimated by inductively coupled plasma-mass spectrometry (ICP-MS) and a mercury analyzer. The concentrations [mean (minimum-maximum) mg/kg] of heavy metals in the ocean fishes were as follows: As=2.523 (0.140-65.543), Cd=0.017 (0.000-0.108), Cu=0.569 (0.040-5.634), Pb=0.023 (0.000-0.323), Hg=0.068 (0.002-0.754), Mn=0.395 (0.016-4.651) and Zn=6.086 (0.529-34.729). The concentrations of heavy metals in the freshwater fishes were: As=0.370 (0.024-2.231), Cd=0.01l (ND-0.086), Cu=0.628 (0.003-1.962), Pb=0.026 (ND-0.423), Hg=0.058 (0.006-0.349), Mn=1.150 (0.069-7.230) and Zn=9.980 (3.463-82.737). The weekly intakes of Cd, Hg and Pb from fish were 0.9, 1.6 and 0.9%, respectively, as compared with the Provisional Tolerable Weekly Intake (PTWl) established by Joint FAO/WHO Expert Committee for food safety evaluation.

Monitoring of Heavy Metals Migrated from Glassware, Ceramics, Enamelware, and Earthenware (유리제, 도자기제, 법랑 및 옹기류 재질의 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Cho, Kyung Chul;Jo, Ye-Eun;Park, So-Yeon;Park, Yongchjun;Park, Se-Jong;Lee, Hye Young
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • This study investigated the migration levels of lead (Pb), cadmium (Cd), and arsenic (As) from food contact articles (glassware, ceramics, enamelware, and earthenware) into a food stimulant (4% v/v, acetic acid). Migration tests were performed at 25℃ for 24 h and all analyses were performed using Inductively-Coupled Plasma Mass Spectrometry (ICP-MS). The method was validated by linearity of calibration curves, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. In glassware, the migration concentrations ranged from not-detected (N.D.) to 752.21 ㎍/L and N.D. to 1.99 ㎍/L for Pb and Cd, respectively. In ceramics, the migration concentrations ranged from N.D. to 1,955.86 ㎍/L, N.D. to 74.06 ㎍/L, and N.D. to 302.40 ㎍/L for Pb, Cd, and As, respectively. In enamelware, the migration concentrations ranged from N.D. to 4.48 ㎍/L, N.D. to 7.00 ㎍/L, and N.D. to 52.00 ㎍/L for Pb, Cd, and Sb, respectively. In earthenware, the migration concentrations ranged from N.D. to 13.68 ㎍/L, N.D. to 0.04 ㎍/L, and N.D. to 6.71 ㎍/L for Pb, Cd, and As, respectively. All results were below the migration limits of Korea standards and specifications for food utensils, containers, and packages.

Monitoring of Heavy Metals Migrated from Polylactide (PLA) Food Contact Materials in Korea (국내 유통 폴리락타이드(PLA) 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Kim, Hyeonuk;Park, So-Yeon;Jo, Ye-Eun;Park, Yongchjun;Park, Se-Jong;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.102-109
    • /
    • 2018
  • In the present study, a variety of polylactide (PLA) articles (n = 211) were tested for migration of lead (Pb), cadmium (Cd) and arsenic (As) into the food simulant (4% v/v acetic acid). Pb, Cd, and As were analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Migration tests were performed at $70^{\circ}C$ and $100^{\circ}C$ for 30 min. The amounts of Pb, Cd, and As increased at $100^{\circ}C$ for 30 min compared with levels at $70^{\circ}C$. However, the migration at both conditions was very low. The maximum level of Pb at $100^{\circ}C$ for 30 min corresponded to 1% of the migration limit. The estimated daily intakes (EDI) based on safety evaluation ranged from $2.5{\times}10^{-5}$ to $2.0{\times}10^{-3}{\mu}g/kg\;bw/day$ for Pb, Cd, and As. The EDI calculated from migration of Pb at $100^{\circ}C$ for 30 min in PLA was the maximum value, $2.0{\times}10^{-3}{\mu}g/kg\;bw/day$, which corresponded to 0.055% of provisional tolerable weekly intake (PTWI, $25{\mu}g/kg\;bw/week$). The data from this study represent a valuable source for science-based safety control and management of hazardous heavy metals migrating from polylactide food contact materials.

Peritoneal Protein Loss in Nephrotic Syndrome on Peritoneal Dialysis (복막 투석 중인 신증후군 환자의 복막을 통한 단백 소실)

  • Ahn, Yo-Han;Jung, Eui-Seok;Lee, Se-Eun;Lee, Hyun-Gyung;Lee, So-Hee;Kang, Hee-Gyung;Ha, Il-Soo;Jung, Hae-Il;Choi, Yong
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.189-196
    • /
    • 2009
  • Purpose : The pathophysiologic mechanism of nephrotic syndrome is not yet known clearly. At least in some cases, certain 'circulating factors' are thought to increase the glomerular protein permeability. Considering the systemic effect of the circulating factor on peritoneal membrane, we evaluated the loss of protein through peritoneal membrane in patients on peritoneal dialysis due to the end stage renal disease (ESRD) caused by steroid resistant nephrotic syndrome (SRNS). Methods : We retrospectively reviewed the medical records of 26 pediatric patients on peritoneal dialysis ensued during the period from 2001 to 2007 at our clinic. Twelve patients had SRNS, while 14 patients had ESRD caused by the congenital anomalies of urinary system. Results : While the other parameters including nPNA indicating the adequacy of protein intake were similar between the two groups, serum albumin was lower in SRNS patients than the non-SRNS patients ($3.7{\pm}0.3$ g/dL vs. $4.0{\pm}0.4$ g/dL, P=0.021). Peritoneal protein loss was higher in SRNS patients than in non-SRNS patients ($3,044.4{\pm}837.6\;mg/m^2$/day vs. $1,791.6{\pm}1,244.0\;mg/m^2$/day, P=0.007). The protein permeability of the peritoneal membrane measured by the ratio of total protein concentration in dialysate to plasma was twice as high in SRNS patients as the non-SRNS ($1.06{\pm}0.46%$ vs. $0.58{\pm}0.43%$, P=0.010). After 1 year, peritoneal protein loss increased in both patient groups, but to a significantly greater degree in non-SRNS patient (P=0.023). Conclusion : The results of our study support the notion that in nephrotic syndrome there are some 'circulating factors' with the systemic effect. Since the greater protein loss through peritoneal membrane in SRNS was confirmed in this study, more meticulous nutritional support and close monitoring on the nutrition are required in these patients.

Monitoring Heavy Metals in Meat and Meat Products (식육 및 그 가공품의 중금속 모니터링)

  • Hwang, Tae-Ik;Ahn, Tae-Hyun;Kim, Eun-Jung;Lee, Jung-Ah;Kang, Myoung-Hee;Jang, Young-Mi;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.525-531
    • /
    • 2011
  • This study was conducted to examine the contents of lead (Pb), cadmium (Cd), arsenic (As), and mercury (Hg) in meat and meat products in Korea. The contents of Pb, Cd, As, and Hg in 466 samples of beef, pork, chicken, duck, ham, and sausage were measured using inductively coupled plasma mass spectrometry or a mercury analyzer. Wet ashing and microwave method were compared, and the recovery and reproducibility of the microwave method were better than those of wet ashing for meat and meat products. The recovery of the microwave method was 98.1% for Pb, 104.6% for Cd, and 103.4% for As, respectively. The best result was obtained through digestion using an acid mixture ($HNO_3$/$H_2O_2$, 6:2). Hg content was measured using a mercury analyzer. As a result, the contents of Hg and Cd in samples were lower than those of Pb and As. The average contents of Pb were 0.009 mg/kg in beef, 0.010 mg/kg in pork, 0.006 mg/kg in chicken, 0.007 mg/kg in duck, 0.005 mg/kg in ham, and 0.009 mg/kg in sausage. The average Cd contents were 0.0004 mg/kg in beef, 0.0004 mg/kg in pork, 0.0005 mg/kg in chicken, 0.0012 mg/kg in duck, 0.0015 mg/kg in ham, and 0.0019 mg/kg in sausage. The average As contents were 0.016 mg/kg in beef, 0.004 mg/kg in pork, 0.021 mg/kg in chicken, 0.010 mg/kg in duck, 0.014 mg/kg in ham, and 0.018 mg/kg in sausage. The average Hg contents were 0.713 ${\mu}g/kg$ in beef, 0.902 ${\mu}g/kg$ in pork, 0.710 ${\mu}g/kg$ in chicken, 0.796 ${\mu}g/kg$ in duck, 1.141 ${\mu}g/kg$ in ham, and 1.052 ${\mu}g/kg$ in sausage. Based on the results of the National Health and Nutrition Survey 2005, the levels of dietary exposure to heavy metal contaminants in meat and meat products were compared with the provisional tolerable weekly intake(PTWI) established by the Joint FAO/WHO Expert Committee on Food Additives. The average dietary exposure of the general population from meat and meat products was 0.03-0.2% of PTWI for Pb, Cd, As, and Hg, which indicates a safe level for public health at present.

The Analysis for Calcium and Fructooligosaccharides Contents in Nutrients Fortified Dairy Products (유가공품 중 칼슘 및 프락토올리고당 영양강화 함량 분석)

  • Park, Ji-Sung;Park, Jae-Woo;Cho, Byung-Hoon;Song, Sung-Ok;Wee, Sung-Hwan;Oh, Soon-Min;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.33 no.6
    • /
    • pp.781-786
    • /
    • 2013
  • Nutrients fortified dairy products declare their contents on the label for nutrition claim and marketing. However, there are few monitoring studies about relations between actual quantities of fortified nutrients and the described ones on the label. This study was carried out for comparing actual fortified nutrient contents with labeled ones. Forty calcium fortified dairy products and twenty four fructooligosaccharides (FOS) fortified dairy products were sampled at supermarkets located in Anyang, Korea from March to November in 2010. Calcium contents were analyzed by using inductively coupled plasma optical emission spectrometry followed by microwave sample digestion, and FOS contents were analyzed by HPLC-ELSD followed by solvent extraction. In fresh milk, calcium contents ranged from 1.0 to 2.4 mg/mL, and those values were 87~127% of their labeled contents. In fermented milk products and cheeses, calcium contents ranged from 0.3 to 1.6 mg/g (89~131% of their labeled contents), 4.2 to 23.0 mg/g (83~127% of their labeled contents), respectively. FOS contents ranged from 9.09 to 18.89 mg/g in FOS contents labeled products and showed 83~154% compared to their labeled quantity, and ranged from 1.3~30.8 mg/g in products without quantity labeling. In conclusion, the amounts of calcium and FOS in dairy products were above 80% compared to their labeled ones and conformed to the Korean official livestock products labeling standard.

Construction of a Fluorescently Labeled Infectious R Peptide-Less Moloney MLV Molecular Clone for Analysis of Syncytium (합포체 분석을 위해 R 펩타이드가 결여된 형광 표지 Moloney 마우스레트로바이러스 Molecular Clone 제조)

  • Lee, Yong-Jin;Park, Jin-Woo;Lee, Kyu-Jun;Bae, Eun-Hye;Park, Sung-Han;Lim, Ji-Hyun;Kim, Sae-Ro-Mi;Jung, Yong-Tae
    • Korean Journal of Microbiology
    • /
    • v.45 no.3
    • /
    • pp.246-250
    • /
    • 2009
  • Retroviruses enter host cells by membrane fusion between the viral Env proteins on the virus membrane and a virus receptor on the cellular membrane. The envelope protein of the ecotropic Moloney murine leukemia virus is synthesized as a gp85 precursor and is proteolytically cleaved into an extracellular surface unit (SU) and the transmembrane protein (TM). The cytoplasmic tail (16 amino acid; R peptide) of the TM protein is further cleaved by the viral protease during virion maturation. Unlike the wild type Env protrin bearing the R peptide, R peptide-truncated Envelope induces syncytia in susceptible cells. To understand the mechanism of R peptidetruncated Env in syncytium formation, R peptide-truncated Env expressing full-length molecular clone containing EGFP in PRR (proline rich region) of Env was constructed. This molecular clone induced syncytia in transfected NIH3T3 cells, fluorescence was detected in the cytoplasm and at the plasma membrane, while the nuclei did not stain and appeared black by fluorescence microscopy. Interestingly, virions with truncated envelope produced from transfected NIH3T3 cells induced syncytia in NIH3T3 cells, but fluorescence was not detected in the same infected cells. It is believed that cell-free viruses direct the fusion of neighboring cells without infection. Our data suggests that use of EGFP-tagged envelope for monitoring syncytium is a sensitive and convenient method. We also found that virion incorporated the R peptide-truncated Env is able to induce the formation of syncytia by fusion from without.