• Title/Summary/Keyword: plasma monitoring

Search Result 353, Processing Time 0.03 seconds

Investigation of Heavy Metals, Residual Pesticides and Nutrient Component from Agricultural By-products Imported as Medium Substrates for Mushroom Cultivation (버섯 재배용 배지 재료로 수입한 농업부산물에서 중금속, 잔류농약, 영양성분 조사)

  • Kim, Jun Young;Lee, Geun Sick;Lee, Chan Jung;Kim, Seong Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.217-221
    • /
    • 2017
  • BACKGROUND: For the food safety of cultivated mushroom, information on the safety of agricultural by-products imported as medium substrates for mushroom cultivation is urgently needed. Therefore, this study was performed to detect the presence of heavy metals, residual pesticides, and nutrient component in the imported medium substrates. METHODS AND RESULTS: Six kinds of medium substrates imported from nine countries from 2015 to 2017 were investigated. A mercury analyzer MA-2000 and an inductively coupled plasma spectrometer OPTIMA 7000DV were used to analyze mercury, lead, arsenic, copper, nickel and cadmium. All of these heavy metals were detected at lower level than heavy metal tolerance standard level of by-product fertilizer in Korea. When 246 kinds of residual pesticides were examined by GC and HPLC, imidacloprid, thiamethoxam and carbendazim were detected from Egyptian beet pulp, Indian cottonseed meal and cottonseed hull, respectively. The content of nutrient components (water, crude ash, crude fat, crude protein and crude fiber) varied among imported countries and the medium substrates. CONCLUSION:The presence of heavy metals and residual pesticides in imported medium substrates for mushroom cultivation was confirmed. For the safe production of mushroom, this study shows that imported medium materials for mushroom cultivation need to be managed through continuous monitoring.

The Use of Vaginal Cytology for the Determination of Estrous Cycle, Optimal Breeding Time and Ovulation Time in Korea Jin-do Dogs (진도개에서 발정주기, 교배적기 및 배란시기 판정을 위한 질세포검사의 이용성)

  • 손창호;백인석;신창록;최한선;강병규
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.114-122
    • /
    • 1996
  • The aim of this study was to assess the precision of the estimates of the time of estrous cycle, optimal breeding and ovulation derived by vaginal cytology. The thirteen Korea Jin-do dogs were examined the vaginal cytology, plasma estradiol-17$$\beta $ and progesterone assay during the estrous cycle. Day 0 was the day of the first male acceptance. The main change of vaginal cytology during the estrous cycle was the high proportion of anuclear cell and erythrocyte in proestrus, superficial cell, anuclear cell and erythrocyte in estrus, parabasal cell, large intermediate cell and leukocytes in diestrus, and parabasal cell and small intermediate cell in anestrus, respectively. These data indicated that vaginal cytology was reliable method for estimating estrous cycle in Korea Jin-do dogs. In the cell indices during estrus the maximum eosinoghilic index was $92.0{\pm}$2.6 (Mean{\pm} SEM$)% at Day 2 and the maximum cornification indez was $96.0{\pm}1.3%$ at Day 2, respectively. The eosinothilic indez and cornification indez of up to 70% were found at Day -1 to Day 5 and Day -6 to Day 8, and up to 80% at Day 1 to Day 4 and Day -4 to Day 6, respectively. From these data it was presumed that eosinophilic index was more reliable index for monitoring optimal breeding time than cornification indexm because eosinophilic index peak period was shorter than cornification indeX peak period and Day 2 was the day of ovulation. Therefore, optimal breeding time was the eosinophilic index peak period, more than 80% of eosinoghilic index. The $estradiol-17{\beta}$ peak, with 3 days delayed when progesterone concentration was $4.5{\pm}0.5 ng/ml$. These data estimated that the ovulation time was the day of eosinophilic index peak, Day 2. breeding time and pvulation time in Korea Jin-do dogs.

  • PDF

Improvement of Measurement Precisions for Uranium Isotopes at Ultra Trace Levels by Modification of the Sample Introduction System in MC-ICP-MS

  • Park, Ranhee;Lim, Sang Ho;Han, Sun-Ho;Lee, Min Young;Park, Jinkyu;Lee, Chi-Gyu;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • v.7 no.2
    • /
    • pp.50-54
    • /
    • 2016
  • Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is currently used in our laboratory for isotopic and quantitative analyses of nuclear materials at ultra-trace levels in environmental swipe samples, which is a very useful for monitoring undeclared nuclear activities. In this study, to improve measurement precisions of uranium isotopes at ultratrace levels, we adopted a desolvating nebulizer system (Aridus-II, CETAC., USA), which can improve signal sensitivity and reduce formation of uranium hydride. A peristaltic pump was combined with Aridus-II in the sample introduction system of MC-ICP-MS to reduce long-term signal fluctuations by maintaining a constant flow rate of the sample solution. The signal sensitivity in the presence of Aridus-II was improved more than 10-fold and the formation ratio of UH/U decreased by 16- to 17- fold compared to a normal spray chamber. Long-term signal fluctuations were significantly reduced by using the peristaltic pump. Detailed optimizations and evaluations with uranium standards are also discussed in this paper.

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

Changes in hematoserological profiles and leukocyte redistribution in rainbow trout (Oncorhynchus mykiss) under progressive hypoxia

  • Roh, HyeongJin;Kim, Bo Seong;Kim, Ahran;Kim, Nameun;Lee, Mu Kun;Park, Chan-Il;Kim, Do-Hyung
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.23-34
    • /
    • 2020
  • In recent years, global warming is causing dramatic environmental changes and deterioration, such as hypoxia, leading to reduced survival rate and growth performance of farmed aquatic animals. Hence, understanding systemic immuno-physiological changes in fish under environmental stress might be important to maximize aquaculture production. In this study, we investigated physiological changes in rainbow trout exposed to hypoxic stress by monitoring changes in blood chemistry, leukocyte population, and expression levels of related cytokine genes. Hematological and serological factors were evaluated in blood obtained from rainbow trout sampled at a dissolved level of 4.6 mg O2 L-1 and 2.1 mg O2 L-1. Blood and head kidney tissue obtained at each sampling time point were used to determine erythrocyte size, leukocyte population, and cytokine gene expression. The level of LDH and GPT in fish under progressive hypoxia were significantly increased in plasma. Likewise, the (Granulocyte + Macrophage)/lymphocyte ratio (%) of fish exposed to hypoxia was significantly lower than that in fish in the control group. Such changes might be due to the rapid movement of lymphocytes in fish exposed to acute hypoxia. In this study, significant up-regulation in expression levels of IL-1β and IL-6 gene appeared to be involved in the redistribution of leukocytes in rainbow trout. This is the first study to demonstrate the involvement of cytokines in leukocyte trafficking in fish exposed to hypoxia. It will help us understand systemic physiological changes and mechanisms involved in teleost under hypoxic stress.

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.21 no.5
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

Effects of the Heat Therapy on Changes of Immune Activities in Human Body (온열요법이 면역활성의 변화에 미치는 효과)

  • Lee, Sang-Bin
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.1
    • /
    • pp.285-292
    • /
    • 2009
  • The purpose of this study was to demonstrate immune-activities by heat therapy. To exam, furthermore, the immune effect is investigated from the healthy volunteer(male:15, female:15) by monitoring changes of immune substances such as complements(C1q, C3, and C4), a comparative study with warm water immersion($40.8{\pm}0.3^{\circ}C$) and infrared(250W) was carried out. The plasma analysis showed that the percentage of C1q, C3, and C4 was decreased in warm water immersion-stimulated group, but not in infrared-applied group, compared with control group from healthy volunteer. Therefore, these results suggest that the thermo-stimulation improved immune activity and inhibited complement-related inflammation through the warm water immersion-dependent classical pathway.

A Study on Air Emission Spectra Observed by Using Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) (Electrothermal-Hollow Cathode Glow Discharge Spectrometry(Et-HCGDS)를 이용하여 살펴본 Air Emission에 관한 연구)

  • Lee, Sang Chun;Shin, Jung-Sook;Kang, Mi-Ra
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.5
    • /
    • pp.399-407
    • /
    • 1995
  • Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) has been constructed in our laboratory for in-situ monitoring of traceble amounts of rare earth elements and actinides. Et-HCGDS is the portable glow discharge system that can perform the trace analysis of elements. The main structural design of Et-HCGDS was based upon the electrothermal heating and glow discharge techniques. More details on Et-HCGDS are available elsewhere. In this study, air was used as a flow gas for the glow discharge system. As a result, the emission spectra of air were collected and the assignment of air emission lines was performed with helps of pure nitrogen and oxygen emission spectra and previously published results. We found that the emission lines of air plasma were mainly due to nitrogen molecules. This paper includes the complete assignments of the air emission lines observed by using Et-HCGDS. Also, this study will be an useful reference for spectrochemical anaysis including air analysis.

  • PDF

APC Technique and Fault Detection and Classification System in Semiconductor Manufacturing Process (반도체 공정에서의 APC 기법 및 이상감지 및 분류 시스템)

  • Ha, Dae-Geun;Koo, Jun-Mo;Park, Dam-Dae;Han, Chong-Hun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.9
    • /
    • pp.875-880
    • /
    • 2015
  • Traditional semiconductor process control has been performed through statistical process control techniques in a constant process-recipe conditions. However, the complexity of the interior of the etching apparatus plasma physics, quantitative modeling of process conditions due to the many difficult features constraints apply simple SISO control scheme. The introduction of the Advanced Process Control (APC) as a way to overcome the limits has been using the APC process control methodology run-to-run, wafer-to-wafer, or the yield of the semiconductor manufacturing process to the real-time process control, performance, it is possible to improve production. In addition, it is possible to establish a hierarchical structure of the process control made by the process control unit and associated algorithms and etching apparatus, the process unit, the overall process. In this study, the research focused on the methodology and monitoring improvements in performance needed to consider the process management of future developments in the semiconductor manufacturing process in accordance with the age of the APC analysis in real applications of the semiconductor manufacturing process and process fault diagnosis and control techniques in progress.

Comparison of Serum Fucose Levels in Leukoplakia and Oral Cancer Patients

  • Rai, Narendra Prakash;Anekar, Jayaprasad;Shivaraja, Shankara YM;Divakar, Darshan Devang;Al Kheraif, Abdulaziz Abdullah;Ramakrishnaiah, Ravikumar;Sebastian, Roopa;Raj, AC;Al-Hazmi, Ali;Mustafa, habil Mohamed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7497-7500
    • /
    • 2015
  • Background: Tumor markers, designated as a broad group of substances produced by malignancies, could be in the form of biochemical substances, immunological substances, cell surface changes and genetic alterations. Cancer, a disorder of cellular behavior is characterized by alteration of serum glycoproteins. L-fucose, a hexose, which is the terminal sugar in most of the plasma glycoproteins, may be useful as a tumor marker for the detection, monitoring and prognostic assessment of malignancies. The aim of the study was to ascertain the role of serum fucose as a biomarker for early detection of oral cancer and to compare serum fucose levels in healthy controls, leukoplakia and oral cancer patients. Materials and Methods: The study included 60 (100.0%) subjects, who were grouped as 20 (33.3%) control subjects, 20 (33.3%) squamous cell carcinoma patients and 20 (33.3%) leukoplakia patients. Fucose estimation was done using UV-visible spectrophotometry based on the method as adopted by Winzler using cysteine reagent. The results were analyzed statistically using ANOVA with Bonferroni post hoc tests. Results: Results showed a high significance in serum fucose in oral squamous cell carcinoma (OSCC) and leukoplakia subjects compared to normal controls. There was a gradual increase in the values noted from control to leukoplakia and to squamous cell carcinoma. Conclusions: Estimation of serum fucose may be a reliable marker and can be used as an effective diagnostic biomarker in oral squamous cell carcinoma patients.