• 제목/요약/키워드: plasma in liquid

검색결과 614건 처리시간 0.025초

He-Polymer Microchip Plasma (PMP) System Incorporating a Gas Liquid Separator for the Determination of Chlorine Levels in a Sanitizer Liquid

  • Oh, Joo-Suck;Kim, Y.H.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권3호
    • /
    • pp.595-598
    • /
    • 2009
  • The authors describe an analytical method to determine total chlorine in a sanitizer liquid, incorporating a lab-made He-rf-plasma within a PDMS polymer microchip. Helium was used instead of Ar to produce a plasma to achieve efficient Cl excitation. A quartz tube 1 mm i.d. was embedded in the central channel of the polymer microchip to protect it from damage. Rotational temperature of the He-microchip plasma was in the range 1350-3600 K, as estimated from the spectrum of the OH radical. Chlorine was generated in a volatilization reaction vessel containing potassium permanganate in combination of sulfuric acid and then introduced into the polymer microchip plasma (PMP). Atomic emission lines of Cl at 438.2 nm and 837.7 nm were used for analysis; no emission was observed for Ar plasma. The achieved limit of detection was 0.81 ${\mu}g\;mL^{-1}$ (rf powers of 30-70 W), which was sensitive enough to analyze sanitizers that typically contained 100-200 ${\mu}g\;mL^{-1}$ of free chlorine in chlorinated water. This study demonstrates the usefulness of the devised PMP system in the food sciences and related industries.

A Simple and Efficient Method to Determine Rivaroxaban in Rat Plasma Using Liquid-Liquid Extraction and LC-MRM

  • Lee, Hyo Chun;Kim, Dong Yoon;Choi, Min-Jong;Jin, Sung Giu;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • 제10권2호
    • /
    • pp.66-70
    • /
    • 2019
  • Rivaroxaban (RRN) is the first available active direct factor Xa inhibitor (anticoagulant) with oral administration. Due to its success in market, there have been efforts to develop various RRN formulations, and the development of good analytical methods for its in vivo evaluation is an essential prerequisite. Thus, here, a simple and efficient method to determine RRN in rat plasma using liquid-liquid extraction (LLE) and liquid chromatography and multiple reaction monitoring (LC-MRM) was presented. The use of ethyl acetate as the LLE solvent results appropriate extraction and purification of RRN and it also helps the significant reduction of rat plasma volume required for RRN quantitation. The developed method showed good analytical performance including specificity, linearity ($r^2{\geq}0.999$ within 0.5 - 500 ng/mL), sensitivity (the lower limit of quantitation at 0.5 ng/mL), accuracy (89.3 - 107.0%), precision (${\geq}12.7%$), and recovery (89.2 - 105.7%). Additionally, RRN in sample extracts showed good stability. Finally, the applicability of the validated method to the PK evaluation of RRN was confirmed after its oral administration to normal rats. The present method is the first analytical method employing LLE for the simple and efficient extraction and purification of RRN in rat plasma. Therefore, the present method can contribute to the development of new RRN formulations as well as to the monitoring of RRN in special clinical situations through its efficient determination in various samples with or without minor modification.

기-액 하이브리드 대기압 플라즈마 반응기 제작 및 특성 분석 (Fabrication and Characterization of Gas-liquid Hybrid Reactor Equipped with Atmospheric Pressure Plasma)

  • 권흥수;이원규
    • Korean Chemical Engineering Research
    • /
    • 제60권3호
    • /
    • pp.452-458
    • /
    • 2022
  • 3가지 종류의 기-액 하이브리드 수평형, 수직형 그리고 needle-to-cylinder형 플라즈마 반응기가 제작되었다. 이들 반응기를 통하여 대기압 플라즈마 방전에서 발생하는 반응 활성종 생성과 전극 내의 전위차를 통한 세정성분의 기-액 활성화 반응을 일으키는 고효율 친환경 기반의 세정 개념을 제시하였다. 세정성능에 대한 효율성을 비교한 결과, needle-to-cylinder형 반응기가 가장 우수한 특성을 가졌다. 본 연구를 통해 기-액 하이브리드 대기압 플라즈마 반응기가 반도체 공정 등 초정밀 세정공정에 응용 가능성이 있음을 확인하였다.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

A Simple and Efficient Method to Determine Montelukast in Rat Plasma Using Liquid-Liquid Extraction and Tandem Mass Spectrometry

  • Kim, Dong Yoon;Lee, Hyo Chun;Jang, Yong Jin;Kim, Jin Hee;Lee, Ha Ryeong;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.71-76
    • /
    • 2020
  • While montelukast (ML), a cysteinyl-leukotriene type 1 receptor (CysLT1) antagonist is widely used to treat symptoms of rhinitis or asthma, its formulations are mainly limited to solid preparation due to its instability. Recently, there have been attempts to develop various ML dosage forms, and this situation increases the demand of sensitive and creditable methods to determine ML in various samples such as plasma. Thus, here, a simple and efficient method to determine ML in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was presented. The mixture of DCM:EtOAc (25:75, v/v), the optimized extract solvent for LLE was found to be effective to extract ML without hydrophilic salts and proteins from the sample with limited volume. Also, the use of zafirlukast, instead of expensive ML-d6, as the internal standard makes the present method economical. The developed method was successfully validated in terms of selectivity, matrix effects (-14.8--6.9%), linearity (r230.998 within 0.5-500 ng/mL), sensitivity (the limit of detection and the lower limit of quantitation, ≤0.5 ng/mL), accuracy (88.4-100.6%), precision (3.0-13.3%), and recovery (80.8-86.3%) by following the FDA guidelines. Finally, the applicability of the validated method to pharmacokinetics (PK) studies was confirmed by the successful determination of PK parameters through it following oral administration of Singulair® granule in rats. Therefore, the present method can contribute to the development of new ML formulations through its performance to determine ML in rat plasma efficiently and sensitively.

대면적 대기압 플라즈마-용액 시스템을 이용한 폴리프로필렌 표면 처리 (Surface Treatment of Polypropylene using a Large Area Atmospheric Pressure Plasma-solution System)

  • 트란꺽시;최호석
    • Korean Chemical Engineering Research
    • /
    • 제49권3호
    • /
    • pp.271-276
    • /
    • 2011
  • 대면적 대기압 플라즈마 반응 장비를 플라즈마-용액 시스템에 적용하여 액상 내부에 잠입된 폴리프로필렌(PP) 필름의 표면손상 없이 관능기 도입 가능성을 탐색하였다. 액상으로 1-butyl-3-methylimidazolium tetrafluoroborate: $[BMIM]^{+}[BF_{4}]^{-}$ 이온성 액체 수용액을 사용한 경우, 안정적으로 플라즈마를 발생시킬 수 있었다. PP 필름의 플라즈마 처리 결과, PP 표면에 다양한 산소 함유 관능기들이 도입되었음을 확인할 수 있었다. 플라즈마 처리 후 PP의 표면 자유에너지는 처리시간, 전압의 증가에 따라서 증가하며, 1.5M 이온성 액체 수용액 농도에서 가장 큰 값을 나타내었다. ATR-FTIR 분석 결과, 다양한 카르보닐 기(1,726 $cm^{-1}$, 1,643 $cm^{-1}$)와 하이드록시 기$(3,100{\sim}3,500\;cm^{-1})$의 흡광도가 증가하였고, XPS 분석은 ATR-FTIR 분석 결과를 뒷받침하여 주었다.

Optical Diagnostics for Pulse-discharged Plasma by Marx Generator and Its Application for Modifications of Hemoglobin and Myoglobin Proteins

  • Park, Ji Hoon;Attri, Pankaj;Hong, Young June;Park, Bong Sang;Jeon, Su Nam;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.176.2-176.2
    • /
    • 2013
  • Property of optical diagnostics for pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is 0.5 ${\mu}F$, to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of 0.5 ${\mu}F$. High voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ~ 1 ${\mu}s$ between the two electrodes of anode-cathode whose material is made of tungsten pin, which are immersed into the liquids. We have investigated the emitted hydrogen lines for optical diagnostics of high voltage pulsed plasma. The emission line of 656.3 nm from $H-{\alpha}$ and 486.1 nm from $H-{\beta}$ have been measured by a monochromator. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium conditions, the electron temperature and density of the high voltage pulsed plasma in liquid could be obtained by the Stark broadening of optical emission spectroscopy. For the investigation of the influence of pulsed plasma on biological proteins, we have exposed it onto the proteins such as hemoglobin and myoglobin. The structural changes in these proteins and their analysis have also been obtained by circular dichroism (CD) and ultraviolet (UV) visible spectroscopy.

  • PDF

Development of Liquid Stub and Phase Shifter

  • Wang, Son-Jong;Yoon, Jae-Sung;Hong, Bong-Guen
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.201-208
    • /
    • 2001
  • The high power RF transmission line components are required for transmitting MW level RF power continuously in RF heating and current drive system which heat the plasma and produce plasma current in fusion reactor The liquid stub and phase shifter is proposed as the superior to the conventional stub and phase shifter. Experimental results show that they are reliable and easy to operate compared to the conventional stub and phase shifter. There is no distortion of reflected power during the raising of the liquid level. RF breakdown voltage is over 40kV. Temperature increment of the liquid is expected not to be severe. These results verify that the liquid stub and phase shifter can be used reliably in the high power continuous RF facilities.

  • PDF

Simple and Sensitive Determination of Baclofen in Human Plasma by Column-Switching and Semi-Micro High-Performance Liquid Chromatography

  • Ban, Eun-Mi;Ko, Hye-Ran;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.284.2-284.2
    • /
    • 2003
  • Using a column-switching technique. highly sensitive and selective semi-micro high-performance liquid chromatographic (HPLC) method has been developed for the determination of baclofen in human plasma. Following precipitation of plasma sample containing baclofen with zinc sulfate-acetonitrile, samples were directly injected on to the system. (omitted)

  • PDF

Fatty Acid Composition in Blood Plasma and Follicular Liquid in Cows Supplemented with Linseed or Canola Grains

  • Perehouskei Albuquerque, Karina;do Prado, Ivanor Nunes;Bim Cavalieri, Fabio Luiz;Rigolon, Luiz Paulo;do Prado, Rodolpho Martin;Pizzi Rotta, Polyana
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제22권9호
    • /
    • pp.1248-1255
    • /
    • 2009
  • This study was carried out to evaluate the fatty acid composition in Nellore cows supplemented with either linseed (n-3) or canola grains (n-6 and n-9). Fifteen Nellore cows, aged five years and bodyweight 550 kg${\pm}$48 kg, were randomly distributed to the following treatments: CON (control), LIN (linseed) and CAN (canola grains). The cows were fed for 80 days. The concentrations of C18:0, C18:2 n-6 and C20:3 n-6 fatty acid were higher (p<0.10) in CON blood plasma in comparison to follicular liquid. Likewise, PUFA, n-6 contents, PUFA:SFA and n-6:n-3 ratios were higher (p<0.10) in blood plasma. On the other hand, C18:1 n-9, C22:5 n-3, MUFA and n-3 contents were lower (p<0.10) in blood plasma. C18:0, C18:2 n-6, C18:3 n-3, C22:5 n-3, PUFA, n-6, n-3 contents and PUFA:SFA ratio were higher (p<0.10) in LIN blood plasma than in the follicular liquid. Nevertheless, C14:0, C16:0, C16:1 n-7, PUFA, C16:0, C18:1 n-9 and MUFA contents were lower (p<0.10) in LIN blood plasma. On treatment CAN, the C18:0 and SFA contents, and n-6:n-3 ratios were higher (p<0.10) in blood plasma. However, C20:3 n-6, C22:5 n-3, PUFA and n-3 contents were lower (p<0.10) in blood plasma. C16:0, C18:0, PUFA, SFA contents and PUFA:SFA ratio did not differ (p>0.10) among the treatments. C14:0, C16:1 n-7, C18:2 n-6 and n-6 contents were higher (p<0.10) for CON and CAN than LIN. C17:1 n-7, C20:4 n-6 and C 22:0 contents were higher (p<0.10) for CAN than CON and LIN. C18:1 n-9, C18:3 n-3, MUFA and n-3 contents were higher (p<0.10) for LIN and CAN than CON. C20:3 n-6 content and n-6:n-3 ratio were higher (p<0.10) for CON than LIN and CAN. C22:5 n-3 content were higher (p<0.10) for CON and LIN than CAN. The concentrations of fatty acids in blood plasma and follicular liquid were not correlated for any fatty acid, independent of the treatment studied. Canola grain added to the diet of Nellore cows resulted in increased concentrations of fatty acids n-6 and n-3 in follicular liquid.