• 제목/요약/키워드: plasma dilution

검색결과 116건 처리시간 0.027초

Iron Determination in Rat Plasma Samples by Inductively Coupled Plasma Emission Spectrometry and Application to Pharmacokinetic Studies

  • Li, Tie-Fu;Deng, Ying-Jie;Ma, Guang-Li;Jin, Jie;Li, Song
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권11호
    • /
    • pp.1571-1574
    • /
    • 2003
  • This paper describes an inductively coupled plasma emission spectrometric method for the analysis of Fe in rat plasma. Calibration curves were obtained in the range of 0.125-1.50 ${\mu}g{\cdot}mL^{-1}$. The relative standard deviation ranges from 5.93% to 6.80%, and accuracy was between 87.6 and 102.0%. Dilution with water had no influence on the performance of the method, which could then be used to quantify Fe concentration in plasma up to 0.50 ${\mu}g{\cdot}mL^{-1}$. The limit of quantification was 0.10 ${\mu}g{\cdot}mL^{-1}$. At this level, the average relative standard deviation was 6.8%. The results indicate that the method meets the accuracy and precision requirements for the pharmacokinetic studies. The Fe concentration in rat plasma was measured and the main pharmacokinetic parameters were calculated by Topfit 2.0 (GmbH. Shering AG, Godecke AG, Germany).

PECVD로 증착된 a-Si박막의 고상결정화에 있어서 기판 온도 및 수소희석의 효과 (Effect of substrate temperature and hydrogen dilution on solid-phase crystallization of plasma-enhanced chemical vapor deposited amorphous silicon films)

  • 이정근
    • 한국진공학회지
    • /
    • 제7권1호
    • /
    • pp.29-34
    • /
    • 1998
  • PECVD방법으로 증착된 비정질 실리콘(a-Si)박막이 고상결정화되고 x-선 회절 (XRD)방법으로 조사되었다. a-Si박막들은 기판 온도 120-$380^{\circ}C$사이에서 Si(100)웨이퍼 위에 $SiH_4$가스 혹은 수소희석된 $SiH_4$가스로 증착되고, $600^{\circ}C$로 가열되어 결정화되었다. 고상화 되었을 때(111), (220), (311)XRD피크들이 나타났고 (111) 우선방위가 두드러졌다. 고상결정 화된 다결정 실리콘(poly-Si)박막들의 XRD피크의 세기는 기판온도가 낮아짐에 따라 증가되 었고, 수소희석은 고상화 효과를 감소시켰다. XRD로 측정된(111)결정립의 평균크기는 기판 온도가 낮아짐에 따라 약 10nm로 증가하였다. 기판온도가 낮아질수록 증착속도는 증가하였 으며, 결정의 크기는 증착속도와 밀접한 관계가 있었다. Si계의 구조적 무질서도가 클수록 고상화에 의한 결정립의 크기도 커지는 것으로 생각된다.

  • PDF

Preliminary study on the use of near infrared spectroscopy for determination of plasma deuterium oxide in dairy cattle

  • Purnomoadi, Agung;Nonaka, Itoko;Higuchi, Kouji;Enishi, Osamu;Amari, Masahiro;Terada, Fuminori
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4101-4101
    • /
    • 2001
  • Information of body composition (fat and protein) in living animal is important to determine the nutrients requirement. Deuterium oxide (D2O) dilution techniques, as one of isotope dilution techniques have been useful for the prediction of body composition. However, the determination of D2O concentration is time consuming and complicated. Therefore this study was conducted to develop a new method to predict D2O concentration in plasma using near infrared spectroscopy technique (NIRS). Four dairy cows in early lactation were used. They were fed total mixed ration containing conr silage, timothy hay, and concentrates to make 17.0%CP and 14.0 MJDE/kgDM. Dosing D2O was at week 1,3 and 5 after parturition. After dosing D2O, the blood was collected from hour 0 to 72. Blood samples were then centrifuge at 3,000 rpm for 10 minutes to obtain plasma. D2O concentration was analyzed by gas chromatograph (deuterium oxide analyzable system, HK102, Shokotsusyou) after extracted from plasma by liophilization. Plasma sample was scanned by NIRS using Pacific Scientific (Neotec) model 6500 (Perstorp Analytical, Silver Spring, MD) in the range of wavelength from 1100 to 2500 nm. Calibration equation was developed using multiple linear regression. Sample from one animal (cow #550; n: 74) was used for developing the calibration while the rest three animals were used for validating the equation. The range, R and SEC of the calibration set samples were 135-925 ppm, 0.93 and 48.1 ppm, respectively. Validation of the calibration equation for three individual cows was done and the average of NIR predicted value of D2O at each collection time from three weeks injection showed a high correlation. The range, r and 53 of plasma from cow #474 were 322-840 ppm,0.93 and 53.1; cow #478 were 146-951 ppm,0.95 and 39.8; cow #942 were 313-885 ppm,0.95 and 37.2, respectively. Judgement of accuracy based on ratio of standard deviation and standard error in validation set samples (RPD) for cow #474, #478 and #942 were 2.2,4.3 and 3.4, respectively. The error in application due to the variation between individual was considered smaller than the bias from collection period, however, this prediction can be overcome with correction of standard zero-minute concentration of blood. The results of this preliminary study on the use of NIRS for determination of D2O in plasma showed very promising as shown by a convenient and satisfy accuracy. Further study on various physiological stage of animal should be done.

  • PDF

Effect of Caffeine, cAMP and Cattle Seminal Plasma on Freezability of Buffalo Bull Semen

  • Singh, P.;Raina, V.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권7호
    • /
    • pp.901-905
    • /
    • 2000
  • An experiment was conducted to investigate the effect of caffeine, cAMP and cattle seminal plasma on preservation of semen at ultra low temperature ($-196{^{\circ}C}$). Each semen sample was divided into four parts equal in volume and sperm concentration; three were treated with caffeine, or cAMP, or cattle seminal plasma (CSP) and the fourth was kept as control. Sperm motility, abnormal spermatozoa, live-dead count and acrosomal damage were studied at different stages of freeze preservation viz.; just after dilution, at $5{^{\circ}C}$, at glycerolisation, before freezing, just after freezing, 24 hours of storage, and one week of storage. Sperm motility (58.39, 61.33, 52.00 and 50.39 per cent), non-eosinophilic spermatozoa (72.55, 69.98, 63.31 and 67.64 per cent), abnormal spermatozoa (5.71, 4.98, 8.04 and 5.66 per cent) and acrosomal damage (13.28, 13.33, 14.80 and 14.65 per cent) were observed in cAMP, caffeine, cattle seminal plasma and control, respectively, at every stage of freeze preservation. From this study it could be concluded that freezability of buffalo semen can be improved through the addition of caffeine followed by cAMP and cattle seminal plasma.

Antimicrobial Effect of Low Temperature Atmospheric Plasma against Oral Pathogens

  • Kim, Young Min;Choi, Byul Bo Ra;Park, Sang Rye;Kim, Ji Young;Kim, Gyoo Cheon
    • International Journal of Oral Biology
    • /
    • 제40권4호
    • /
    • pp.167-173
    • /
    • 2015
  • The purpose of this study was to investigate the antibacterial effect of the low temperature atmospheric plasma device with needle tip designed for easy approach to the oral cavity and root canal against Streptococcus mutans, Enterococcus faecalis and Candida albicans. The antibacterial activities evaluated by measuring clear zone of agar plate smeared with each bacteria after plasma treatment. To quantify antibacterial effects, dilution plate method was used. In addition, scanning electron microscope (SEM) was used for observation of changes in bacterial morphology. As treatment time of plasma increased, the clear zone was enlarged. The death rate was more than 99%. The SEM results showed that the globular shape of bacteria was distorted. These results suggest that needle tip plasma could be an innovative device for prevention of dental caries, and treatment of apical infection and soft tissue diseases.

Ion Chromatography에 의한 혈액중에서 양이온의 분석에 관한 연구 (A Study on the Analysis of Cation in Blood by Ion Chromatography)

  • 박성우;김을환
    • 한국환경보건학회지
    • /
    • 제17권1호
    • /
    • pp.89-94
    • /
    • 1991
  • There are many pretreatment and detection methods for divalent cations in blood. But our purpose was to study the pretreatment of blood for the determination of cations by Ion Chromatography. We compared with recovery of Mg$^{++}$, and Ca$^{++}$ contained in plasma according to four pretreatment methods, that is, add of trichloroacetic acid and perchloric acid, dilution with distilled water and membrane filter method. As a result, add of trichloroacetic acid was found to be the most suitable method for good recovery of Mg$^{++}$ (98.0%) and Ca$^{++}$(96.0%) in plasma, and the Mg$^{++}$ and Ca$^{++}$ contents in plasma was 20 and 102 ($\mu$g/ml)

  • PDF

사람성장(成長)홀몬의 방사면역측정(放射免疫測定)에 관한 연구 - 제I편 사람성장(成長)홀몬의 측정법에 관한 검토 (Studies on the Radioimmunoassay of Human Growth Hormone - 1. Evaluation of the method of determination)

  • 이영우;이홍규;고창순;이문호
    • 대한핵의학회지
    • /
    • 제6권1호
    • /
    • pp.17-24
    • /
    • 1972
  • Utilizing the commercial radioimmunoassay kit, the author assayed HGH and evaluated the problems of the method. The method had the sensitivity of 0.5 mug/ml degree and could determine the plasma HGH concentration directly without the help of plasma extraction. Also it was specific for the HGH, when tested by a dilution method using test utilizing the plasma of the acromegalic patient. The author also obtained the $^{125}I$ labelled HGH of specific activity of $156.3{\mu}Ci/{\mu}g$, performing the chloramine-T method.

  • PDF

Enhancement of seed germination and microbial disinfection on ginseng by cold plasma treatment

  • Lee, Younmi;Lee, Young Yoon;Kim, Young Soo;Balaraju, Kotnala;Mok, Young Sun;Yoo, Suk Jae;Jeon, Yongho
    • Journal of Ginseng Research
    • /
    • 제45권4호
    • /
    • pp.519-526
    • /
    • 2021
  • Background: This study aimed to investigate the effect of cold plasma treatment on the improvement of seed germination and surface sterilization of ginseng seeds. Methods: Dehisced ginseng (Panax ginseng) seeds were exposed to dielectric barrier discharge (DBD) plasma operated in argon (Ar) or an argon/oxygen mixture (Ar/O2), and the resulting germination and surface sterilization were compared with those of an untreated control group. Bacterial and fungal detection assays were performed for plasma-treated ginseng seeds after serial dilution of surface-washed suspensions. The microbial colonies (fungi and bacteria) were classified according to their phenotypical morphologies and identified by molecular analysis. Furthermore, the effect of cold plasma treatment on the in vitro antifungal activity and suppression of Cylindrocarpon destructans in 4-year-old ginseng root discs was investigated. Results: Seeds treated with plasma in Ar or Ar/O2 exhibited a higher germination rate (%) compared with the untreated controls. Furthermore, the plasma treatment exhibited bactericidal and fungicidal effects on the seed surface, and the latter effect was stronger than the former. In addition, plasma treatment exhibited in vitro antifungal activity against C. destructans and reduced the disease severity (%) of root rot in 4-year-old ginseng root discs. The results demonstrate the stimulatory effect of plasma treatment on seed germination, surface sterilization, and root rot disease suppression in ginseng. Conclusion: The results of this study indicate that the cold plasma treatment can suppress the microbial community on the seed surface root rot in ginseng.

Determination of Trace Impurities in Gold by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Gae-Ho;Yang, Suk-Ran;Park, Chang-Jun;Lee, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권6호
    • /
    • pp.696-700
    • /
    • 1993
  • Gold bonding wire of 0.076 mm in diameter used in semiconductor industry, is dissoved in aqua regia. The solution is then evaporated to near dryness several times with a few drops of HCl added to prepare the final sample solution in 5% HCl. The gold matrix is separated from trace impurities by controlled potential deposition. The whole electrolysis has been carried out inside a clean bench. An optimum potential is found to be +0.25 V to give more than 99.9% Au matrix removal with better than 90 analytes remaining in the electrolyte solution. Isotope dilution calibration is employed to get the best accuracy and precision. Analytical results are presented with determination limits of the analytical method.

플라즈마 화학 기상 증착법을 이용한 탄소나노튜브의 성장 분석 및 전계방출 특성 (Field Emission Characteristics and Growth Analysis of Carbon Nanotubes by Plasma-enhanced Chemical Vapor Deposition)

  • 오정근;주병권;김남수
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1248-1254
    • /
    • 2003
  • Carbon nanotubes(CNTs) are grown by using Co catalyst metal. CNTs fabricated by PECVD(plasma enhanced chemical vapor deposition) method are studied in terms of surface reaction and surface structure by TEM and Raman analysing method and ate analysed in its electrical field emission characteristics with variation of space between anode and cathode. Acetylene(C$_2$H$_2$) gas is used as the carbon source, while ammonia and hydrogen gas are used as catalyst and dilution gas. The CNTs grown by hydrogen(H$_2$) gas plasma indicates better vortical alignment, lower temperature process, and longer tip, compared to that grown by ammonia(NH$_3$) gas plasma. The CNTs fabricated with Co(cobalt) catalyst metal and PECVD method show the multiwall structure in mid-circle type in tip-end and the inner vacancy of 10nm. Emission properties of CNTs indicate the turn-on field to be 2.6 V/${\mu}{\textrm}{m}$ We suggest that CNTs can be possibly applied to the emitter tip of FEDs and high brightness flat lamp because of low temperature CNTs growth, low turn-on field.