• 제목/요약/키워드: plant recovery

검색결과 722건 처리시간 0.023초

법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 - (A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo -)

  • 정승원;이강준
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

원자력발전소의 노심냉각회복 조치에 대한 운전원 조치시간 평가 (An Evaluation of Operator's Action Time for Core Cooling Recovery Operation in Nuclear Power Plant)

  • 배연경
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.229-234
    • /
    • 2012
  • Operator's action time is evaluated from MAAP4 analysis used in conventional probabilistic safety assessment(PSA) of a nuclear power plant. MAAP4 code which was developed for severe accident analysis is too conservative to perform a realistic PSA. A best-estimate code such as RELAP5/MOD3, MARS has been used to reduce the conservatism of thermal hydraulic analysis. In this study, operator's action time of core cooling recovery operation is evaluated by using the MARS code, which its Fussell-Vessely(F-V) value was evaluated as highly important in a small break loss of coolant(SBLOCA) event and loss of component cooling water(LOCCW) event in previous PSA. The main conclusions were elicited : (1) MARS analysis provides larger time window for operator's action time than MAAP4 analysis and gives the more realistic time window in PSA (2) Sufficient operator's action time can reduce human error probability and core damage frequency in PSA.

대규모 지진해일로 인한 침수 및 배수 시스템 프레임워크에 대한 연구 (Flooding and recovery system framework for Tsunami)

  • Lee, Sun Kee
    • 시스템엔지니어링학술지
    • /
    • 제8권2호
    • /
    • pp.47-55
    • /
    • 2012
  • Tsunami disaster, which ruined Japan Fukushima nuclear power plant sites in 2011 March, has raised not only the perception of that Tsunami and/or large scale flooding possibly surpass the design baselines for industry facilities and plants, but also the necessity to establish recovery system against flooding. This study suggests the framework for flooding and drainage system in compliance with flooding and drainage concept to define and identify requirements, functions, and components of the system with traceable relations. The framework with combination to CMMI engineering process is the base of corresponding high level system design.

유동 불균일이 전열관 튜브에 미치는 영향 (Influence on heat transfer due to uneven flow)

  • 정재헌;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.273-279
    • /
    • 2008
  • The purpose of this study is not only to evaluate thermal performance but also to find the stress behavior of heat transfer tubes under the part load operation in Heat Recovery Steam Generator. Flow analysis was performed to know the behavior of exhaust gas from gas turbine and thermal performance was calculated using distribution of hot exhaust velocity. In addition, tubes temperature during operation were gathered from actual plant to verify the uneven flow distribution under part load operation. Stress analysis was performed using tubes temperature data gathered from actual plant under both part and full load operations to know the stress behavior of tubes.

  • PDF

The Optimal Composition of Cold Bonded Pellet for Recycling EAF Dust Directly to the Furnace

  • Lee, Kwang-Keun;Kim, Tai-Dong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.370-374
    • /
    • 2001
  • The degree of iron recovery from dust agglomerates was investigated experimentally to determine the optimum mixing ratio of coke in cold bonded pellet(CBP) which is fed into electric arc furnace(EAE) in the minimill plant. From the XRD analysis for EAF dust, magnetite(Fe$_3$O$_4$) and franklinite(ZnFe$_2$O$_4$) was identified as major components. Maximum iron recovery was obtained for the solid carbon content of approximately 18 weight percent. From plant trials of CBP composed of this optimal mixing condition, it was observed that electric power consumption and sulfur content increased with increasing the quantity of CBP.

  • PDF

잔존수명을 활용한 제조설비의 경제적 감가상각률 추정방안 (A Study on the Estimation of Economic Depreciation Rate on Industrial Property U sing Remianing Life)

  • 오현승;조진형
    • 산업경영시스템학회지
    • /
    • 제33권3호
    • /
    • pp.219-224
    • /
    • 2010
  • Depreciation accounting has as its main objective, the recovery of the original cost of plant investment less net salvage, over the estimated useful life of that plant. Accuracy of the whole life technique in meeting this objective depends entirely on the original estimates of service life and net salvages for an account. Where the whole life technique has been used and original estimates prove inaccurate, excessive or deficient accumulations in the depreciation reserve frequently occur. To overcome this, the remaining life technique is suggested to better match the challenges of accelerated technology and competition within the regulated environment. The flexibility of the remaining life technique will allow an even chance to provide a complete recovery of the original cost.

옥수수(Zea mays L.) 자엽초 절편에서 Naphtylphthalamic Acid에 대한 오옥신 이동계의 감지적응 (Sensory Adaptation in Polar Auxin Transport System to Naphtylphthalamic Acid in Corn Coleoptile Segments)

  • 윤인선
    • Journal of Plant Biology
    • /
    • 제34권4호
    • /
    • pp.317-323
    • /
    • 1991
  • Partial recovery in auxin transport capacity from inhibition by N-naphthylphthalamic acid (NPA) was observed when corn coleoptile segments were subjected to a prolonged NPA treatment. Kinetic data indicated that the recovery time is a function of the concentration of NPA applied. Desensitization to NPA was also seen in tissue slices where NPA increased net uptake of auxin, indicating that the apparant adaptation in the auxin transport system did not results possibly from auxin accumulated during transport inhibition. Studies on in vitro binding of NPA to membrane vesicles isolated from the coleoptile indicated that preincubation of the tissue with NPA resulted in the reduced binding activity. Scatchard analysis of the data indicated that this was due to decreases in the number of NPA binding sites. The possibility of causal relationship of modified NPA receptors to the sensory adaptation in auxin transport observed in coleoptile segments will be discussed.

  • PDF

생물학적 축산분뇨처리시설에서 인 회수의 가능성 평가 (Feasibility of Phosphorus Recovery from Biological Livestock Wastewater Treatment Plant)

  • 안조환;김장호;민성재
    • 한국물환경학회지
    • /
    • 제32권4호
    • /
    • pp.343-348
    • /
    • 2016
  • A chemical sequencing batch reactor was operated to test the feasibility of nutrient recovery from a biological livestock wastewater treatment plant. Both phosphate and ammonia could be successfully recovered as magnesium ammonium phosphate (MAP) crystals. The contents of TP and TN in the recovered MAP crystals were 26.2% and 4.0%, respectively. Zn, Cr and Ti were identified in the crystals, but the contents remained below the Korean standard for an organic fertilizer. Chemical analyses confirmed that the MAP crystals could be useful phosphate fertilizers. On the other hand, the results of physical analyses using an X-ray diffractometer and an energy dispersive X-ray spectrometer strongly suggested that crystalline materials like magnesium potassium phosphate (KMP) and hydroxyapatite (HAP) were also formed during the MAP crystallization, depending on the availability of K+ and Ca2+.

원자로 압력 및 체적제어계통의 다단 오리피스 설계 (Design of Multistage Orifices for PIC System in Nuclear Reactor)

  • 신정철
    • 에너지공학
    • /
    • 제24권2호
    • /
    • pp.17-21
    • /
    • 2015
  • 다공 및 다단오리피스열을 해석할 수 컴퓨터코드를 사용하여 원자력발전소 내 공급 및 배출장치의 수축오리피스를 설계하였다. 원래 단공 오리피스가 설치되었으나 다공 오리피스 설치가 필요하여 설계 변경되었다. 오리피스 사이 거리는 충분한 압력회복거리로 유지되었다. 최소 정압은 공동현상 방지를 위하여 그 온도에 상응하는 증기압 이하로 유지되도록 설계하였다. 오리피스 설치 배관의 직경은 운전시 강성을 유지할 수 있도록 원래 크기보다 증가시켰다.

HRSG 보일러 튜브 내면 스케일의 특성연구 (A Study on Characteristics of HRSG Boiler Inner Tube Scale)

  • 이승민;민병연;정년호
    • Corrosion Science and Technology
    • /
    • 제11권3호
    • /
    • pp.82-88
    • /
    • 2012
  • The thickness and chemical composition of oxides on heat recovery steam generator tubes of combined cycle power plant were examined in order to evaluate the corrosion of the tubes. Tubes were removed from the plant after actual operations for 21,482, 42,552 and 56,123 hours respectively. Thickness and growth rate of the oxide scale on reheater inner tube (SA213-T22) were very high compared to those other tubes. The oxide scale was about $250{\mu}m$ thick and uniform. The components of the scale were iron oxides. The oxide scale was mixed oxides consisting of magnetite$(Fe_3O_4)$ and hematite$(Fe_2O_3)$. The oxide on inner tube was removed using many kinds of chemicals and it was found that chelating agents were dissolved faster than other chemicals.