• Title/Summary/Keyword: plant parameters

Search Result 1,822, Processing Time 0.059 seconds

Performance Improvement for PID Controllers by using Dual-Input Describing Function (DIDF) Method (DIDF를 이용한 PID제어기의 성능향상에 관한 연구)

  • Choe, Yeon-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1741-1747
    • /
    • 2011
  • Though various techniques have been studied as a way of adjusting parameters of PID controllers, no perfect method of determining parameters is available to date. This paper proposes a new method for enhancing performance of PID controllers by using the characteristics of dual-input describing function (DIDF). In other words, if nonlinear elements with two inputs (DIDF) are connected in series to the plant, the critical point (-1+j0) for Nyquist stability theory can be moved to a position arbitrarily selected on the complex plane by determining necessary coefficients of the DIDF appropriately. This makes the application of the existing conventional PID parameter tuning methods a lot easier, and stability and robustness of the system are improved simultaneously due to the DIDF inserted.

A Study on Design Characteristics of Yeosu Circulating Fluidized Bed Boiler (여수화력 순환유동상 보일러의 설계특성 고찰)

  • Kim, Jae-Sung;Lee, Jong-Min;Kim, Dong-Won;Kim, Tae-Hyun;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • 340 MWe circulating fluidized bed (CFB) boiler in Yeosu power station is under construction. The circulating fluidized bed boiler in the Yeosu power plant has a number of differences from other domestic boilers in terms of scale and design. Evaluation of design parameters of the Yeosu CFB boiler should be required because the direct application of existing technology is limited. In this study, design characteristics of the Yeosu CFB boiler was summarized. And thermogravimetric analysis was conducted with comparing other rank coals. Watersteam side heat absorption, flue gas temperature and heat transfer coefficient were calculated by heat and mass balance. Design parameters for the Yeosu CFB boiler were discussed along with typical value in the CFB design range.

Robust regulator design for an interval plant (구간 플랜트에 대한 견실한 레귤레이타 설계)

  • 김기두;김석중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.173-178
    • /
    • 1993
  • In this paper, we present an algorithmic technique for determining a feedback compensator which will stabilize the interval dynamic system, specifically, the robust regulator design for interval plants. The approach taken here is to allow the system parameters to live within prescribed intervals then design a dynamic feedback compensator which guarantees closed-loop system stable. The main contribution of this paper is the idea of introducing a "simplified Kharitonov's result" for low order polynomials to search for suitable compensator parameters in the compensator parameter space to make the uncertain syste robust. We also design the robust regulator which will D-stabilize (have the closed-loop poles in the left sector only) the dynamic interval system while having good performance. The nuerical examples are given to show the substantially improved robustness which results from our approach. approach.

  • PDF

New design of variable structure control based on lightning search algorithm for nuclear reactor power system considering load-following operation

  • Elsisi, M.;Abdelfattah, H.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.544-551
    • /
    • 2020
  • Reactor control is a standout amongst the most vital issues in the nuclear power plant. In this paper, the optimal design of variable structure controller (VSC) based on the lightning search algorithm (LSA) is proposed for a nuclear reactor power system. The LSA is a new optimization algorithm. It is used to find the optimal parameters of the VSC instead of the trial and error method or experts of the designer. The proposed algorithm is used for the tuning of the feedback gains and the sliding equation gains of the VSC to prove a good performance. Furthermore, the parameters of the VSC are tuned by the genetic algorithm (GA). Simulation tests are carried out to verify the performance and robustness of the proposed LSA-based VSC compared with GA-based VSC. The results prove the high performance and the superiority of VSC based on LSA compared with VSC based on GA.

A Study on the Optimal Design of Fuzzy Logic Controller (퍼지제어기의 최적 설계에 관한 연구)

  • 노기갑;김성호;주영훈;박진배
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.50-54
    • /
    • 1997
  • In general, the design of fuzzy logic controller has difficulties in the acquisition of expert's knowledge. So, some methods that can optimize the parameters for fuzzy logic controller automatically without expert knowledge was provided. Recently, tuning method for fuzzy logic controller using genetic algorithm(GA) were proposed in many papers. However, those are tuning methods for a part or some part of fuzzy logic controller. In this paper, we proposes auto tuning method for the whole part of tuzzy logic controller, such as parameters of membership functions for antecedence and consequence parts, rule base, scaling factor and the number of rule. Finally, second order dead time plant is provided to show the advantages of the proposed method.

  • PDF

Position Control of Permanent Magnet Synchronous Motor using Adaptive Variable Structure System Control Strategy (적응 가변구조계 제어 이론에 의한 영구자석형 동기전동기의 위치제어)

  • Lee, Y.J.;Lee, I.H.;Oh, W.S.;Son, Y.D.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.591-595
    • /
    • 1989
  • The application of Variable Structure System (VSS) to the position control of a Permanent Magnet Synchronus Motor is discussed. VSS is expected to be a powerful and potential tool to construct new control strategy for ac machines, since the resulting system shows robust performance to parametic variations and disturbances. An adaptive VSS which can make corrections or adjustments in the parameters of the control device of the VSS in accordance with the current values of the plant parameters and the constraints on the control is preposed. Various simulation results are reported to show the validity of the proposed control method.

  • PDF

A Study on the Hydraulic Turbine Governor using Automatic Tuning Fuzzy Controller (자동 동조 퍼지 제어기를 이용한 수력 발전소 조속기 연구)

  • Lee, Seon-Geun;Lee, Won-Yong;Shin, Dong-Ryul;Kwon, Oh-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.265-268
    • /
    • 1992
  • The control performances of a fuzzy controller depend on its control rules, I/O membership functions, and scaling factors. Scaling factors are very important to adjust control parameters to the process which is to be controlled. For tuning the sealing factors, trial and error method is used in conventional fuzzy controller, which is very difficult and time consuming. This paper proposes a tuning method of scaling factors based on the concept of tuning rules for the conventional Pl controller parameters. The proposed automatic tuning fuzzy controller was evaluated by computer simulations. Good results have been obtained for the small hydro power plant.

  • PDF

Observer Based Sliding Mode Controller for Nonlinear System using Dynamic Rule Insertion

  • Seo, Ho-Joon;Kim, Dong-Sik;Seo, Sam-Jun;Park, Jang-Hyun;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.67.2-67
    • /
    • 2001
  • In the adaptive fuzzy sliding mode control, from a set of fuzzy IF-THEN rules adaptive fuzzy sliding mode control whose parameters are adjusted on-line according to some adaptation laws is constructed for the purpose of controlling the plant to track a desired trajectory. Most of the research works in nonlinear controller design using fuzzy systems consider the affine system with fixed grid-rule structure based on system state availability. The fixed grid-rule structure makes the order of the controller big unnecessarily, hence the on-line fuzzy rule structure and fuzzy observer based adaptive fuzzy sliding mode controller is proposed to solve system state availability problems. Therefore adaptive laws of fuzzy parameters ...

  • PDF

Optimum seat design for the quadruple offset butterfly valve by analysis of variance with orthogonal array

  • Lee, Sang-Beom;Lee, Dong-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.961-967
    • /
    • 2014
  • In onshore and offshore plant engineering, a broad use of pipe system have been achieved and accordingly related technologies has been developed especially in the field of flow control valves. The aim of this study is to suggest the quadruple offset butterfly valve for bi-directional applications which show equivalent operating torque characteristics of the triple offset butterfly valve. Seat design parameters for the quadruple offset butterfly valve are determined by the proposed method utilizing both ANOVA (analysis of variance) and the orthogonal array. Through additive model considering the effect of design parameters on seating torque, mean estimation is performed and thus its optimization results are verified by design of experiment results. The insight obtained from the present study is beneficial for valve design engineers to develop reliable and integrated design of the quadruple offset butterfly valve.

Quantitative Interpretation of Cooling Rate of Clinker and It's Effects on the Cement Strength Development (클링커 냉각속도의 정량적 해석 및 냉각속도가 시멘트 강도발현에 미치는 영향고찰)

  • Kim, Chang-Bum;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.4 s.299
    • /
    • pp.224-229
    • /
    • 2007
  • To evaluate the cooling rate of clinker quantitatively, several clinkers with different cooling rate were made in the laboratory. The X-ray diffraction pattern of Ferrite 002 reflection were measured and the parameters were calculated by using split type pseudo-Voigt function. The X-ray diffraction patterns of the Ferrite phase in the clinkers from cement manufacturing plant were analyzed by using the parameters and the analysis program was developed to calculate the cooling rate quantitatively. The cooling rate coefficients of the clinkers were calculated by using the profile fitting method of the program and the influence of cooling rate on strength was evaluated. The results show that there is a close relation between the cooling rate of clinker and the strength of cement.