• 제목/요약/키워드: plant's noise

검색결과 116건 처리시간 0.031초

전기비저항, 바크하우젠노이즈 및 탄화물 분석법을 이용한 2.25Cr-1Mo 강의 열화도 평가 (Evaluation of degradation in aged 2.25CrMo steel by electrical resistivity, magnetic Barkhausen noise and carbide analysis)

  • 변재원;표승우;권숙인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.210-215
    • /
    • 2001
  • The ferritic 2.25CrMo steel has been used for high temperature structure applications such as turbine rotors, boilers and pressure vessels in fossil plant and petroleum chemical facilities. However, this steel is known to result in aging degradation due to temper embrittlement, carbide induced brittleness and softening of matrix after long time exposure to high temperature. This research investigated the microstructural and mechanical changes after artificial degradation treatment and evaluated the degree of degradation by several nondestructive methods. The decrease of electrical resistivity and increase of magnetic Barkhausen noise(RMS voltage) with increasing aging time were observed. The change of electrical resistivity and Barkhausen noise showed a good correlation with the ductile-brittle transition temperature.

  • PDF

저속 2행정 디젤엔진의 과도 비틀림 진동에 의한 축계 피로 강도에 관한 연구 (A Study on Shaft Fatigue Strength due to Torsional Vibrations in Two Stroke Low Speed Diesel Engines)

  • 이돈출;김상환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.786-791
    • /
    • 2006
  • Two stroke low speed diesel engines are mainly used for marine propulsion or power plant prime mover. These have many merits such as higher thermal efficiency, mobility and durability. However various annoying vibrations sometimes occur in ships or at the plant itself. Of these vibrations, torsional vibration is very important and it should be carefully investigated during the initial design stage for engine's safe operation. In this paper authors suggest a new estimation method of for shaft's can be calculated equivalently from accumulated fatigue cycles number due to torsional vibration. The 6S70MC-C($25,320ps{\times}91rpm$) engine for ship propulsion was selected as a case study, and the accumulated fatigue cycles numbers for shafting life time converted from the measured angular velocity and torsional vibration stress was calculated. This new method can be realized and confirmed in test model ship with two stroke low speed diesel engine.

  • PDF

중성자 신호이용 원자로 내부 구조물 감시시스템 구성 (Composition of Diagnostic System for Reactor Internal Structures Using Neutron Noise)

  • 박종범;김종봉;박진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2252-2254
    • /
    • 2002
  • The Reactor internal structures which consist of many complex components are subjected to flow-induced vibration due to high temperature and pressure in Reactor coolant system. The above flow-induced vibration causes degradation of structural integrity of the Reactor and may result in loosing mechanical binding component which might impact other equipment and component or cause flow blockage. It is important to analyze reactor noise signal for the early detection of potential problem or failure in order to diagnosis reactor integrity in the point of view of safety and plant economics. Detailed composition of diagnostic system reactor internal structures using neutron noise(RIDS).

  • PDF

대형 화력 발전용 발전기 권선단부의 전자기력에 의한 진동 해석 (Vibration Analysis of the End-winding of Large Generator for Fossil Power Plant under Electromagnetic Excitation)

  • 김철홍;주영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.350-355
    • /
    • 2003
  • This paper presents results of vibration analysis of a end-winding of large generator for fossil power plant. A finite element analysis using a commercial S/W is performed to calculate alternating electromagnetic forces, mainly of 120㎐ in 60㎐ machines, acting on the end-winding, and then to calculate forced response of the end-winding under electromagnetic forces. Also, this paper presents analytical and experimental modal analysis results of generator end-winding to validate FE model. We calculated forced response of end-winding on 120㎐, double rotating frequency. These results will be used to evaluate structural reliability of end-winding and applied to update model.

  • PDF

500MW 급 대형 발전기 권선단부의 전자기력과 동특성 해석 (Analysis of Vibration and Electromagnetic Forces on a Generator End-winding for 500 MW Fossil Power Plant)

  • 김철홍;주영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.826-831
    • /
    • 2001
  • Electromagnetic forces generate vibrations in the end-winding of large generators. A finite element analysis using a commercial S/W is performed to calculate electromagnetic force of end-winding in two pole generator for 500 MW fossil power plant. Also, this paper presents analytical and experimental modal analysis results of generator end- winding. Using validated FE model, 3D electromagnetic model which computes the forces on the end-winding is coupled with a 3D mechanical model which calculates the dynamic displacement and stress under electromagnetic forces. These results will be used to evaluate reliability of end-winding and applied to update model.

  • PDF

화력 발전용 시험연소로의 연소시험 중의 연소진동 실험(I) (Experiments of Combustion Vibration in the Pilot Furnace for Fossil Power Plant under Combustion Test (I))

  • 주영호;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.341-344
    • /
    • 2004
  • This paper presents results of test for combustion vibration in the pilot furnace for fossil power plant under combustion test. We measured static pressure variation in the pilot furnace together with air and fuel flow. From test results, it shows that vibration magnitude is affected by air and fuel flow. Also, a finite element analysis using a commercial S/W is performed to calculate acoustic mode of the pilot furnace. These results show that dominant frequency occurred is related to acoustic natural frequency of furnace. After this, it needs to be studied the relation between dominant frequency of combustion vibration and air flow rate.

  • PDF

풍력발전시설에서 발생하는 환경소음 및 저주파음에 관한 연구 (Study on Noise and Low Frequency Noise generated by Wind Power plant(Wind Farm))

  • 박영민;정태량;손진희
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.425-434
    • /
    • 2011
  • The energy produced by wind power generation is a clean energy product because it is acquired by using renewable resource. Wind power plants("wind farms), in Korea, have been built and operated as 345.6MW facilities from 2001 until now 2009. Nevertheless, environmental issues regarding construction of wind power plants have arisen. accordingly it is time to consider the environmental and social issues of wind power in accordance with the government's policy objectives of increased wind power production. In this study, we investigated the influence that noise and low frequency noise caused by Wind power plants have on neighborhood and residents. We also sought solutions to these issues. In order to analyze the issues of wind power facilities, we compared and examined precedents and the solutions for noise and low frequency noise in Europe, the United states and Japan. We intended to examine the influences of wind power facilities and propose alternative in dealing with these issues.

APR1400 원자로 내부구조물 종합진동평가프로그램용 측정센서 검토 (A Review of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400)

  • 고도영;이재곤
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.47-55
    • /
    • 2011
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. nuclear regulatory commission regulatory guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors because the measurement is conducted during the critical path of the construction period of nuclear power plants. Therefore, we analyzed RVI thermal-hydraulic and structure design data of Palo Verde nuclear power plant(U.S.), Yonggwang nuclear power plant(Korea) and APR1400 and researched measuring sensors used in them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected suitable measuring sensors for RVI CVAP in advanced power reactor 1400(APR1400).

도로 발생 분진의 방음벽 충돌 CFD 분석 (Collision CFD Analysis of Noise Barrier of Road-Generated Particulate)

  • 이재엽;김일호
    • 한국도로학회논문집
    • /
    • 제19권6호
    • /
    • pp.31-36
    • /
    • 2017
  • PURPOSES : The computational fluid dynamics of flow and fine particles in a road were set to determine the insert flow and occurrence characteristics. METHODS : The road extension was 100 m with two lanes. A one-ton truck traveled a 50-m distance. After a noise barrier was installed on one side of the road, the flow and a collision analysis were tested. RESULTS : The flow that occurred was 5 m/s beside the vehicle, and fine particulate was $5.0{\times}10^2{\mu}g/m^3$ after 20 m from the exhaust vent. CONCLUSIONS : After a collision analysis of the fine particulate on the noise barrier to find the most suitable position of the filter panel in height, the bottom 1 m was the most optimum position because 88.1% of the distribution was concentrated there.

산업용 송풍기 소음기의 성능개선을 위한 실험적 연구 (An Experimental Study on the Performance Improvement of Industrial Blower Silencer)

  • 김병삼;김용우
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1060-1069
    • /
    • 2005
  • Silencers are engineering devices that are designed to attenuate sound waves propagating in a flowing medium. The muffler type silencer has a series of chambers in parallel or series utilizing the reflection and expansion characteristics of the expansion chambers, sidetubes, branch resonators, and tailpipes to attenuate the sound. To Improve the performance of industrial blower silencer of muffler type which is employed in petrochemical plant, this paper seeks its optimal arrangement of buffs by experimental method and suggests optimal arrangement of buffs. Experimental results show that the optimal one suggested can reduce the noise level as much as 14 dB (or 18 dB(A)) in the laboratory and as much as 4 dB(A) compared to that of the existing silencer on the ground.