References
- Korea Hydro and Nuclear Power Co., 2001, Advanced Power Reactor 1400 Standard Safety Analysis Report.
- U. S. Nuclear Regulatory Committee, 2007, Regulatory Guide 1.20, Comprehensive Vibration Assessment Program for Reactor Internals during Preoperational and Initial Startup Testing, Rev. 3.
- Korea Electric Power Corp., 2000, Report on the Observation and Synthesis about CVAP in KNGR RVI.
- Korea Electric Power Corp., 1995, Special Test Part, Collection of Experience Record for Preoperational and Initial Startup Testing for Yonggwang Generating Station Unit 3, 4.
- Korea Heavy Industry Co., 1995, A Comprehensive Vibration Assessment Program for Yonggwang Nuclear Generating Station Unit 4, Final Evaluation of Pre-Core Hot Functional Measurement and Inspection Program.
- Jung, S. H., 2005, Reactor Vessel Internals Comprehensive Vibration Assessment Program for Korea Standard Nuclear Power Plant, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 15, No. 5, pp. 7-14.
- Ko, D. Y., Lee, J. G. and Kim, K. H., 2009, Vibration Measurement Plan of RVI CVAP for Shin-kori Unit 4, Transactions of the Korean Nuclear Society Spring Meeting, pp. 1037-1038.
- Kim, K. H., Ko, D. Y. and Kim, Y.-S., 2009, Hydraulic and Structural Analysis Methodology of RVI CVAP in Shin-kori 4, Transactions of the Korean Nuclear Society Spring Meeting, pp. 1113-1114. https://doi.org/10.1152/japplphysiol.00142.2002
- Ko, D. Y., Lee, J. G. and Kim, K. H., 2009, Preliminary Determination of Measurement Sensors and Location for RVI CVAP of Shin-kori #4, Proceedings of the Conference on Information and Control Systems, pp. 216-217.
- Kepco Engineering and Construction Company Inc., 2008, Design Specification for Reactor Vessel Core Support and Internal Structures.
- Kepco Engineering and Construction Company Inc., 2008, Fluid System and Component Engineering Design Data for Plant Safety, Containment and Performance Analyses.
- Kepco Engineering and Construction Company Inc., 2008, System Description for Reactor Internals Assembly.
- Kepco Engineering and Construction Company Inc., 2008, Reactor Vessel Core Support and Internal Structures System Design Requirements.
- Kepco Engineering and Construction Company Inc., 2008, Design Data for The Hydraulic Loads on Reactor Internals During Normal Operation.
- Combustion Engineering Inc., 1984, A Comprehensive Vibration Assessment Program for the Prototype System 80 Reactor Internals Palo Verde Nuclear Generating Station Unit 1.
- Korea Institute of Nuclear Safety, 1995, Technical Review Report of Reactor Vessel Internals Comprehensive Vibration Assessment Program for Yonggwang Nuclear Power Station Unit 4.
- http://www.vibro-meter.com
- http://www.kyowa-ei.co.jp