• 제목/요약/키워드: pipe material

검색결과 704건 처리시간 0.024초

상수관로의 노후도 영향인자 및 가중치 산정에 관한 연구 (Estimation of Deterioration and Weighting Factors in Pipes of Water Supply Systems)

  • 김응석;김중훈;이현동
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.686-699
    • /
    • 2002
  • The purpose of this study is to estimate deterioration factors and weighting factors in pipe network which each local self-governments takes rehabilitation and replacement work present time. Deterioration factors in pipe network are able to effected of specific province or location related with water supply. Most of water supply pipes are laid under the ground, it is hard to quantify deterioration degree of water system. Moreover, the timing and economic limitation and insufficient information on the spot survey gives a difficulty to look over how old water supply system is. Accordingly, this study collects and analyses five data as the laying environment, visual analysis, analysis of soil contents, analysis of pipe material, and questionary survey data in water pipe of A city. The deterioration factor estimates 14 factors with excavation and experimental analysis and 9 factors without excavation and experimental analysis. Also, the weighting factors are estimated by using the multiple linear regressions and the linear programming. The estimated deterioration factor and weighting results are compared the analysis result of visual, pipe material, and soil contents with the Probabilistic Neural Network Model. Consequently, the model results of estimated 9 factors in this study and 14 factors show the 1-2% difference. The result show that the proposed model could be used to decide the deterioration condition of pipe line with real excavation and experimental analysis.

현장시험을 통한 이중보온관 되메움 대체재료에 관한 연구 (A Study on Alternative Backfill Material for Pre-insulated Pipe through the Field Tests)

  • 최봉혁;김진만;유한규
    • 대한토목학회논문집
    • /
    • 제32권1C호
    • /
    • pp.1-6
    • /
    • 2012
  • 본 논문에서는 이중보온관의 다짐시공 중 안정성 평가 및 되메움 대체재료 제시를 위하여 현장시험을 수행하였다. 현장시험 시 사용된 되메움 재료는 기존 되메움 재료인 중사와 되메움 대체재료 평가를 위한 자연모래 2종(세사, 왕사)과 부순모래, 자갈 2종(10mm, 20mm)을 사용하였다. 현장시험은 되메움재료 별 이중보온관 토압 및 변형, 외관손상 등의 거동 특성 평가를 위하여 수행하였다. 연구결과에 따르면, 부순모래는 5종의 되메움 대체재료 별 평가결과 이중보온관에 미치는 공학적 특성 및 재료의 수급 측면에 있어 기존 중사를 이용하는 이중보온관 되메움재의 대체재료로 가장 합리적인 재료로 평가되었다.

$621^{\circ}C$급 화력발전용 소재 실기규모 Mock-up품 구조용접부 특성평가 (Characteristic Evaluation of mock-up Structural Welding between casting and pipe for USC TPP)

  • 이명열;지병하;송근호;김정태
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.39-41
    • /
    • 2007
  • In this study, actual scale welding were conducted at the USC thermal power plant turbine and main steam pipe casting candidate mock up material 9Cr-1.5Mo-CoVNbNB steel(CB2) and 9Cr-0.5Mo-MVNbN steel(P92). And to evaluate the welding process for the actual production, mechanical property testes were conducted for the weld metal. The Mock-up welding condition successfully led to an excellent structural welding joint between casting and pipe material.

  • PDF

다공성 물질을 통과하는 관내 유동에서의 미세 입자 응축성장 전산 가시화 (Computational visualization for condensational growth of micro-particles in the pipe flow through a porous material)

  • 문지후;김대겸
    • 한국가시화정보학회지
    • /
    • 제20권2호
    • /
    • pp.63-69
    • /
    • 2022
  • In this study, we numerically simulate the condensational growth of micron-sized particles traveling through a pipe filled with humidified air. Using the finite volume method and Lagrangian particle tracking technique, the mixture of particle-laden flow with moist air in a T-juction pipe is simulated. The condensational growth of particles is calculated by considering the mass transfer of vapor in the air onto the particle surface. The results indicate that the growth rate of the particles increases as the relative humidity of air is higher. Furthermore, the placement of a porous media with low permeability in the pipe could enhance the degree of condensational growth.

유수대류계수에 관한 실험적 연구 (Experimental Study on Coefficient of Flow Convection)

  • 정상은;오태근;양주경;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2000
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structure, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection is developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect in internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. finally a prediction model of the coefficient of flow convection is proposed using experimental results from the developed device. According to the proposed prediction model, the coefficient of flow convection increases with increase in flow velocity and decreases with increase in pipe diameter and thickness. Also, the coefficient of flow convection is largely affected by the type of pipe materials.

  • PDF

Standardization and Method Selection for the Trenchless Repair Technology of Sewer using Cured-in-place Pipe

  • Kim, Taeeung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.70-78
    • /
    • 2022
  • The trenchless entire repair technology (TERT) have many different names depending on the companies, and they have the same or similar methods as well as materials. In addition, there was quiet difficulty in application of field working and even confuse to classify for new TERT, while application criteria of TERT is not listed systematically. This study proposed standardization and method for TERT affecting by pipe condition, working materials, working method, specification/quantity per unit according to field condition, strange affairs and others. Determination criteria of defective sewer pipe has proposed to effective method which modify a criteria between Ministry of Environment and Seoul Metropolitan City. A Cured-in-place pipe (CIPP) is suitable for TERT, and the design criteria for the entire broken pipe are proposed when the pipe itself deforms more than 10%. A check lists are specimen preparing, hardening site made by clamped mold, numbers, flexural and tensile property, water leak and desquamation test, and have to use material property of minimum CIPP value depend on ISO 11296-4, ISO 11297-4, KS M3550-7 and KS M3550-9.

영광원자력 배관소재의 재료물성치 평가 (II) -안전주입계통- (Evaluation of Material Properties for Yonggwang Nuclear Piping Systems(II) - Safety Injection System-)

  • 김영진;석창성;장윤석
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1451-1459
    • /
    • 1995
  • The objective of this paper is to evaluate the material properties of SA312 TP316 and SA312 TP304 stainless steels and their associated welds manufactured for safety injection system of Yonggwang 3,4 nuclear generating stations. A total of 62 tensile tests and 46 fracture toughness tests were conducted and the effects of various parameters such as pipe size, crack plane orientation, tests were conducted and the effects of various parameters such as pipe size, crack plane orientation, test temperature, welding on material properties were discussed. Test results show that the effect of test temperature on fracture toughness was significant while the effects of pipe size and crack plane orientation on fracture toughness were negligible. Fracture toughness of the weld metal was in general higher than that of the base metal.

Effects of Diverse Water Pipe Materials on Bacterial Communities and Water Quality in the Annular Reactor

  • Jang, Hyun-Jung;Choi, Young-June;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권2호
    • /
    • pp.115-123
    • /
    • 2011
  • To investigate the effects of pipe materials on biofilm accumulation and water quality, an annular reactor with the sample coupons of four pipe materials (steel, copper, stainless steel, and polyvinyl chloride) was operated under hydraulic conditions similar to a real plumbing system for 15 months. The bacterial concentrations were substantially increased in the steel and copper reactors with progression of corrosion, whereas those in stainless steel (STS) and polyvinyl chloride (PVC) reactors were affected mainly by water temperature. The heterotrophic plate count (HPC) of biofilms was about 100 times higher on steel pipe than other pipes throughout the experiment, with the STS pipe showing the lowest bacterial number at the end of the operation. Analysis of the 16S rDNA sequences of 176 cultivated isolates revealed that 66.5% was Proteobacteria and the others included unclassified bacteria, Actinobacteria, and Bacilli. Regardless of the pipe materials, Sphingomonas was the predominant species in all biofilms. PCR-DGGE analysis showed that steel pipe exhibited the highest bacterial diversity among the metallic pipes, and the DGGE profile of biofilm on PVC showed three additional bands not detected from the profiles of the metallic materials. Environmental scanning electron microscopy showed that corrosion level and biofilm accumulation were the least in the STS coupon. These results suggest that the STS pipe is the best material for plumbing systems in terms of the microbiological aspects of water quality.

비회 운송관의 수명연장을 위한 유리섬유 복합재의 개발: 내마모성 평가 (Development of Glass Fiber Composite Material to Extend the Life of Fly Ash Transport Pipe: Wear Test)

  • 정규상;장윤상
    • 청정기술
    • /
    • 제15권1호
    • /
    • pp.16-22
    • /
    • 2009
  • 본 연구에서는 화력발전소에서 마모 및 주기적인 파손으로 문제가 발생하는 저회 운반용 주철관을 대체하기 위하여 내마모 성능이 우수한 FRP관을 개발하였다. 불포화 폴리에스테르, 비닐에스테르, 에폭시, 페놀 등4종의 수지와 탄화규소 내마모재를 사용하여 시편을 제작하고ASTM D4060 마모시험 및 분사식 마모시험을 수행하였다. ASTM D4060 마모시험에서는 최적의 수지 종류와 내마모재 크기, 내마모재와 수지의 혼합비율을 찾고 내마모성을 극대 화하였다. FRP와 주철을 비교한 시험에서는 FRP 시편이 주철 시편에 비하여 작은 마모량을 보여 주철관의 FRP 파이프로의 대체 가능성을 보여 주었다. 현장시험을 위하여 시제품 파이프를 제작한 후 기존 회처리라인에 적용한 결과 FRP관이 내마모성에서 기존의 주철관보다 우수함을 보여주었다.

각종 송출 호오스의 구경 및 길이가 농용양수로의 소요동력에 미치는 영향 (Influence of Flowing Velocity and Length of Delivery Hoses on Power Requirement of Agricultural pump.)

  • 김기대;김성래;이한만
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.46-52
    • /
    • 1979
  • The water delivery hose for agricultural pump is getting popular in rural areas in korea. Friction head loss, discharge, and power requirements were measured in various discharge for different material and diameter of hose to get basic data for economical use in agricultural pump. The results attained in this study were as follows ; 1. Friction head loss increased significantly as the velocity increased, and the difference of velocity between the different diameter of hose was bigger than that between materials, which was resulted in the increase of the friction head loss. 2. Friction head loss in the case of that the velocity with 2m/sec was constant was about 3.53 to 4.01 m/100m in the diameter 3" and about 2.30 to 3.10 m/100m in the diameter 4". Material A of diameter 3" showed the maximum value 8.4m/100m in Reynolds number $2.0\times10^5$, 4" got the minimum value 2.24m/100m, the difference between these values was bigger than 6m per 100 meters in the friction head loss. 3. Darcy-Weisbach formular with friction coefficient [f] calculated by Nikurades formular in the smooth pipe or with friction coefficient [f] calculated on the base of C value 125 in Hazen-Williams formular was available in friction head loss of the water discharger hose in rural areas. 4. Total head increased as friction head loss increased , meanwhile total discharge decreased, and 20 percents of energy was more saved in Material C 4″pipe than Material A 3″pipe in the view point from the discharge per unit power requirement, this phenomenon suggested that long distance pipe would be advantage in larger diameter pipe for save of energy. for save of energy.

  • PDF