• Title/Summary/Keyword: pinhole

Search Result 208, Processing Time 0.024 seconds

Development of Nipkow Disk for High-Speed Confocal Probe Using Micro-lens and Pinhole Disks (마이크로 렌즈 디스크와 핀홀 디스크를 이용한 고속 공초점용 닙코 디스크 개발)

  • Kim, Gee Hong;Lee, Hyung Seok;Kim, Chang Kyu;Lim, Hyung Jun;Lee, Jae Jong;Choi, Kee Bong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.636-641
    • /
    • 2014
  • This paper discusses the fabrication process for a Nipkow disk using micro-lens and pinhole disks. The confocal measuring system that uses the Nipkow disk has the advantage in measuring speed, because the Nipkow disk can simultaneously provide confocal images of all pixels in a CCD camera without requiring a lateral scanning unit. A micro-lens configuration, which focuses illumination on a pinhole, overcomes the low optical efficiency of the Nipkow disk system and allows its use in practical applications. This paper describes how to design the Nipkow disk in terms of numerical aperture, particularly for measuring the height of solder bumps in packaging application and for hybrid processes combining mechanical and semiconductor processes.

Performance Test of the Inorganic Surface Preparation Materials Using EVA Powder Resin for Wall (EVA 분말수지를 이용한 벽체용 무기질 바탕조정재의 성능평가)

  • Chang, Jin-Ho;Kang, Byeong-kwen;Chang, Sung-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.305-307
    • /
    • 2013
  • In this paper, we test and evaluate in terms of workability the epoxy resin mortar and the EVA powder resin mortar used on the concrete structures. The initial viscosity of the epoxy resin mortar is lower than the EVA powder mortar, but after 20 minutes work can not be rapidly increased to 40 minutes. In the other hand, the EVA powder resin mortar is able to measure of viscosity for the past 40 minutes. In the flow test for evaluate workability, the flow of the epoxy resin mortar is rapidly decreased from 230 to 100 in the 90 minutes, but the flow of the EVA powder resin mortar is reduced to 198 to 175 that there is no significant change. In the coverage test of the pinhole on the concrete surface, the EVA powder mortar appears coverage in the all pinhole size but the epoxy resin mortar is not concealed from 2mm pinhole size.

  • PDF

초고에너지 우주선과 고층대기 극한방전 현상 관측을 위한 TUS(Tracking Ultraviolet Setup) 및 Pinhole Camera 개발 및 진행상황

  • Kim, Min-Bin;Kim, Ji-Eun;Kim, Ye-Won;Na, Go-Un;Park, Il-Heung;Seo, Jeong-Eun;Lee, Jik;Jeong, Ae-Ra;Garipov, G.;Khrenov, B.;Klimov, P.;Panasyuk, M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.209.1-209.1
    • /
    • 2012
  • TUS(Tracking Ultraviolet Setup)는 5x1019 eV 이상의 초고에너지 우주선의 스펙트럼과 그 기원, 그리고 고층대기 극한방전 현상(TLE) 관측을 위한 우주망원경이다. 위성 Lomonosov의 탑재체로 2013년에 발사예정에 있으며 지구로부터 550km 상공에서 지구를 돌며 3년 이상 임무를 수행할 예정이다. TUS는 크게 반사경과 Detector Module 두 부분으로 나뉜다. 7개의 육각형 프레넬 거울을 이용한 $2m^2$ 크기의 반사경과 256개의 PMT(Photo Multiplier Tube)로 구성된 Detector Module을 이용하여 지구 대기에서 초고에너지 우주선에 의해 발생하는 UV fluorescence와 Cherenkov light를 관측한다. TUS Detector Module의 한 부분인 Pinhole Camera는 본 연구단의 기술로 직접 개발한 탑재체로서 TUS 반사경을 통하지 않고 두개의 $8{\times}8$ 어레이 MAPMT (Multi Anode PMT)가 직접 지구를 바라보며 고층대기 극한방전 현상을 관측한다. Pinhole camera는 TUS의 시야각을 포괄하는 넓은 시야각을 가지고 있으며 빠른 트리거 시스템으로 고층대기 극한 방전 현상을 관측하며, 이 방전현상과 TUS가 관측하는 초고에너지 우주선과의 상관 관계를 연구한다. 현재 TUS 및 Pinhole Camera는 러시아에서 조립되어 우주환경 인증 시험 및 인터페이스 테스트가 진행되고 있다. 본 발표에서는 TUS와 Pinhole Camera를 소개하고 현재까지의 진행상황 및 테스트 결과에 대해 보고하고자 한다.

  • PDF

Wavefront Aberration Measurement of DVD pick-up lenses with a Shack-Hartmann Sensor and a Point Source (Shack-Hartmann 파면분석기와 점광원을 이용한 DVD 픽업 렌즈의 수차 측정)

  • Kang, Dong-Won;Lee, Jin-Seok;Hahn, Jae-Won
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.135-138
    • /
    • 2007
  • Using a Shack-Hartmann sensor and sub-wavelength sized pinhole point source, we develope an optical testing system that measures the wavefront error of high numerical aperture and small sized optical components. The subwavelength sized pinhole generates perfect spherical waves with large diffraction angle and this makes possible to test high numerical aperture optics. The Shack-Hartmann sensor reconstructs the wavefront and calculates the aberrations. We make a home-made reference plane wave source which generates nearly perfect plane waves and the calibration with this plane source gives the overall uncertainty of the optical testing system 0.010 $\lambda$ rms.

  • PDF

Influence of Surface Tension on Pinhole Phenomenon of Earthen Ware Glazes (도기유의 표면장력이 Pinhole 현상에 미치는 영향)

  • 지응업;이경재
    • Journal of the Korean Ceramic Society
    • /
    • v.13 no.3
    • /
    • pp.3-12
    • /
    • 1976
  • The corelation between surface tensions and surface appearances of SK O5a opaque glazes for earthen wares were investigated. The surface tension values were theoretically calculated by using Dietzel's factors of constituent oxides of glaze. The surface appearances of glazes, especially the pinhole phenomena were strongly effected by the surface tension values showing the following general tendencies: (1) In the range of 305±3 dynes/cm of surface tensions, glazes showed almost no pjnholes. (2) In the range of surface tensions less than 300 dynes/cm, the large numbers of small pinholes or eggshell textures were observed. (3) In the range of surface tensions higher than 310 dynes/cm, large and deep pinholes were observed. (4) The contact angles of glazes on the wall tile body substrate are in the good proportional agreement with the surface tension values calculated by Dietzel's factors.

  • PDF

Pinhole Scintigraphic Manifestations of Sternocostoclavicular Hyperostosis -Report of A Case- (흉골.늑골.쇄골 과골증(Sternocostoclavicular Hyperostosis)의 바늘구멍 골스캔 소견 -1예 보고-)

  • Bahk, Yong-Whee;Chung, Soo-Kyo;Kim, Sung-Hoon;Jung, Woo-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.155-159
    • /
    • 1992
  • Sternocostoclavicular hyperostosis (SCCH) is a chronic, nonsuppurative inflammatory disease involving sternum, clavicle, upper ribs and its adjacent soft tissue. It is a relatively newly described syndrome, characterized by ossification in the region between the clavicle and the first rib, and hyperostosis of the medial end of the clavicle with simultaneous involvement of the sternum and juxtasternal ribs. We experienced one case of sternocostoclavicular hyperostosis, diagnosed by pinhole bone scintigraphy. This paper describes characteristic pinhole scintigraphic findings of SCCH, with comparative study with radiographic and pathologic findings.

  • PDF

x$^{(3)}$ Measurement through Self-focusing with Non-gaussian Beam (비 Gaussian 빛에 의한 자체집광을 이용한 x$^{(3)}$측정)

  • 이범구
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.428-433
    • /
    • 1993
  • The second harmonic of Q-switched Nd:YAG laser beam with gaussian mode is cut off by pinhole of a certain radius and its central portion passed through pinhole is focused by converging lens. It is confirmed that the shape of this beam in focal region is central symmetric but non-gaussian. Change of transmittance due to self-focusing is investigated by scanning (z-scan) $CS_2$ of 1 mm thickness in the focal region. It is found that the observed results can be consistently explained by Fresnel theory within 1.5% accuracy and efficiency of self-focusing depends on spatial shape of incident beam.

  • PDF

The Analysis for PDP Discharge as a Parameter of Electrode Structure by 3-Dimensional Light Emission Measurement (3차원 광 측정을 통한 PDP의 전극 구조별 방전 분석)

  • Woo, Seok-Gyun;Choi, Hoon-Young;Lee, Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.190-196
    • /
    • 2001
  • We measured 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting method(SPDM). The SPDM has the point detector with pinhole. The light emitted from PDP cell at the in-focus position can pass through the pinhole and be collected by detector. On the contrary, the light emitted from PDP cell at the out-of-focus positions is focused on the front of or the behind of the pinhole. We could analyze the characteristic of 3-dimensional light emission distribution by SPDM. From 3-dimensional measurement of 828[nm], the efficient design of PDP cell, the importance of opening ration, and the relations between BUS electrode position and discharge intensity are obtained. Also, the relationship between discharge characteristics and sustain electrode structures in AC-PDP are studied by measuring luminance, current, and discharge voltage.

  • PDF

The 3-Dimensional Analysis for AC-PDP Discharge by Light Emission Measurement (AC-PDP의 3차원 광 측정을 통한 방전 분석)

  • 우석균;최훈영;이승걸;이석현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.577-580
    • /
    • 2000
  • We measured 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting method(SPDM). The SPDM has the point detector with pinhole. The light emitted from PDP cell at the in-focus position can pass through the pinhole and be collected by detector. On the contrary, the light emitted from PDP cell at the out-of-focus positions is focused on the front of or the behind of the pinhole. We could analyze the characteristic of 3-dimensional light emission distribution by SPDM. From 3-dimensional measurement of 828nm, we found that the efficient design of PDP cell, the importance of opening ratio, and the relations between BUS electrode position and discharge intensity are obtained.

  • PDF

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF