• 제목/요약/키워드: pin-hole

검색결과 200건 처리시간 0.029초

20년 이상 장기저장된 홍삼의 이화학적 특성변화 및 품질안정성 (The Changes of Physicochemical Characteristics and Quality Stability of Korean Red Ginseng (Panax ginseng C.A. Meyer) Stored over 20 Years)

  • 곽이성;한민우;배봉석;안남근;유혜영;박철수;백인호;조병구
    • 생약학회지
    • /
    • 제48권4호
    • /
    • pp.329-338
    • /
    • 2017
  • This study was investigated the changes of quality stability and physicochemical characteristics of the Korean red ginsengs stored for a long times over 20 years. The Korean red ginsengs were stored for 4 to 22 years in canned packaging with polypropylene film and wooden box at room temperatures. The unusal phenomena such as discoloration and pin hole in packaging were not observed. General bacteria showed the vlaues of below 100 CFU/g, coliform groups and molds were not found in any samples stored for 22 year. Any samples also were not detected in mycotoxins. The contents of moisture, ash and crude saponin were the levels of 10.6~11.1%, 3.8~4.2% and 4.1~4.7% during the whole storage periods, respectively. The contents of maltol, which has been known as characteristic flavour and antioxidant of Korean red ginseng, showed remarkably increasing tendency from 0.10 mg/g for 4 years to 2.53 mg/g for 22 years during the storage. The contents of AFG (arginyl-fructosyl-glucose), arginine and free sugar were slightly decreased. Acidic polysaccharide and ginsenoside were not changed significantly during the storage periods. The contents of acidic polysaccharide and total ginsenosides were the 75.1~76.3 mg/g and 15.1~16.6 mg/g, respectively. The sums of ginsenoside-Rg1,-Rb1 and -Rg3s were the ranges of 9.3~9.9 mg/g and PD (ginsenoside-Rb1, -Rb2,-Rc,-Rd,-Rg3s,-Rg3r)/PT (ginsenoside-Rg1,-Rg2,-Re,-Rf,-Rh1) saponin ratios were the levels of 1.4~1.5. These results suggest that Korean red ginsengs stored for long periods show relatively stable quaility stabilities and not significantly changed the contents of ginsenoside and polysaccharide during the storage up to 22 years.

과학 교사 연수에서의 동료 교수법의 효과 및 교사의 인식 (Effect and Recognition of Peer Instruction in Training of In-service Science Teachers)

  • 김종원;김규환;이지원;황명수;김중복
    • 과학교육연구지
    • /
    • 제36권1호
    • /
    • pp.84-93
    • /
    • 2012
  • 이 연구에서는 초 중학교 교사를 대상으로 동료 교수법(Peer Instruction)을 활용한 교사 연수를 통해 그들의 개념 변화 정도와 새로운 연수 방법에 대한 인식을 조사함으로써 교사 연수에 동료 교수법의 도입 가능성을 알아보고자 하였다. 자료는 초 중 과학 교사 전문성 신장 연수에 참여한 교사 169명을 대상으로 바늘구멍 사진기의 원리를 가르치기 위하여 빛의 직진에 관한 개념 검사 6문항을 이용하여 동료 교수법을 적용한 후, 그 중 초등교사 24명, 중학교 교사 32명을 대상으로 동료 교수 전과 후의 정답률을 분석하였으며, 인식 조사는 연수에 참여한 전체 교사를 대상으로 설문을 실시하여 이에 응답한 135명의 의견을 분석하여 수집하였다. 연구결과는 첫째, 연수에 참여한 교사들의 사전 개념 수준이 낮음에도 불구하고 동료교수 후 약 0.7의 높은 수준의 개념 변화가 있었다. 흥미 있는 결과는 초등 교사가 중등보다 사전 정답률이 더 높았으며 개념변화도 더 잘 이루어졌다. 둘째, 연수에 참여한 교사들은 동료 교수법 수업에 적극적으로 참여하였으며 동료 교수법이 과학 개념을 형성하는데 도움이 되고, 동료 교수법을 학생 수업에 도입하는 것에 긍정적으로 반응하였다. 셋째, 초 중 교사 모두 교사 연수에서 과학 개념을 다루는 것을 중요하게 인식하고 있었으며, 이를 위해 교사 연수에 동료 교수법이 도입되는 것을 긍정적으로 평가하였다.

  • PDF

니켈 표면처리공정에서 전류밀도 효과분석 (Effect of Current Density on Nickel Surface Treatment Process)

  • 김용운;정구형;홍인권
    • 공업화학
    • /
    • 제19권2호
    • /
    • pp.228-235
    • /
    • 2008
  • 니켈 표면처리 공정에서 전류밀도에 따라 니켈의 전착두께가 증가되었으며, 증가폭은 $6{\sim}10A/dm^2$에서 저전류보다 높게 나타났다. 전류밀도를 측정하기 위해 Hull-cell 분석을 수행 하였다. 최적 공정온도는 $60^{\circ}C$, pH는 3.5~4.0이었고, 전해용액 중 니켈이온의 농도는 300 g/L 이상에서 농도에 따라 전착두께가 증가되었다. 전류밀도에 따라 용액 중 니켈이온 감소 속도가 증가되었는데, 이는 음극표면에서 니켈 전착 량에 따른 전착두께의 증가를 나타낸다. 그러나 전착속도가 빠를 경우 니켈 전착 층의 치밀성은 저하되며, 표면의 상태는 불규칙하게 변화된다. 니켈이온의 전착과정이 불규칙하게 일어나 조직의 pin hole 등을 야기해 표면특성을 저하시키는 것으로 확인되었다. 광택니켈 전착 후 25 h 내식을 유지한 결과, 낮은 전류밀도를 유지하는 것이 내식특성이 우수한 것으로 나타났다. 프로그램모사 결과, 전류밀도가 높아질수록 확산 층의 두께는 증가하며, 음극표면의 농도는 낮아진다. 농도분포는 낮은 전류밀도에서 고른 분포를 나타내었으며 이는 일정한 전착두께를 예측할 수 있다. 생산성 저하를 예방하기 위해 공정시간은 크게 변화시키지 않았으며, 전류밀도와 전착두께를 변화시키면서 공정변수를 조절하였다. 본 연구의 표면분석 결과 조직특성이나 내식성 등의 표면 물성이 낮은 전류밀도를 사용할 경우에 더욱 우수한 것으로 나타났다.

Atmospheric Turbulence Simulator for Adaptive Optics Evaluation on an Optical Test Bench

  • Lee, Jun Ho;Shin, Sunmy;Park, Gyu Nam;Rhee, Hyug-Gyo;Yang, Ho-Soon
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.107-112
    • /
    • 2017
  • An adaptive optics system can be simulated or analyzed to predict its closed-loop performance. However, this type of prediction based on various assumptions can occasionally produce outcomes which are far from actual experience. Thus, every adaptive optics system is desired to be tested in a closed loop on an optical test bench before its application to a telescope. In the close-loop test bench, we need an atmospheric simulator that simulates atmospheric disturbances, mostly in phase, in terms of spatial and temporal behavior. We report the development of an atmospheric turbulence simulator consisting of two point sources, a commercially available deformable mirror with a $12{\times}12$ actuator array, and two random phase plates. The simulator generates an atmospherically distorted single or binary star with varying stellar magnitudes and angular separations. We conduct a simulation of a binary star by optically combining two point sources mounted on independent precision stages. The light intensity of each source (an LED with a pin hole) is adjustable to the corresponding stellar magnitude, while its angular separation is precisely adjusted by moving the corresponding stage. First, the atmospheric phase disturbance at a single instance, i.e., a phase screen, is generated via a computer simulation based on the thin-layer Kolmogorov atmospheric model and its temporal evolution is predicted based on the frozen flow hypothesis. The deformable mirror is then continuously best-fitted to the time-sequenced phase screens based on the least square method. Similarly, we also implement another simulation by rotating two random phase plates which were manufactured to have atmospheric-disturbance-like residual aberrations. This later method is limited in its ability to simulate atmospheric disturbances, but it is easy and inexpensive to implement. With these two methods, individually or in unison, we can simulate typical atmospheric disturbances observed at the Bohyun Observatory in South Korea, which corresponds to an area from 7 to 15 cm with regard to the Fried parameter at a telescope pupil plane of 500 nm.

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • 한국환경성돌연변이발암원학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

얼음증발기 용접방법 개선에 관한 연구 (A Study on the Improvement of Welding Method for Ice Evaporator)

  • 이정연;유흥렬;손영득
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.558-564
    • /
    • 2021
  • 정수기는 최근 시장규모가 급격한 증가 추세에 있으며, 얼음 정수기의 얼음 생성량과 냉수 성능을 결정하는 핵심 부품인 증발기의 용접기술 향상을 요구하고 있다. 얼음 정수기의 finger type 증발기는 얼음을 탈빙 시키는 방법으로 순간 히터 방식과 고온 가스 방식으로 크게 구분되며 일부 대기업을 중심으로 생산 및 개발이 진행되고 있다. 두 방법은 장·단점을 가지고 있으며 고온 가스 방식 증발기는 특히 생산과정에서 고열의 산소 용접으로 인해 동파이프 내부에 pin hole 현상과 고압관 용접시 막힘 문제가 간헐적으로 발생하고 있다. 이는 정수기 사용시 얼음과 차가운 물의 생기지 않는 문제점을 가져오며 현장에서 수리가 불가능하다. 이러한 문제점을 해결하기 위해 본 논문에서는 고온 가스 증발기의 용접 불량을 개선하기 위해 cap jig를 적용하였다. 또한 산소용접 불꽃 크기를 조절하여 cap jig에 열원이 잘 공급될 수 있도록 하고 파압 시험과 테스트와 열충격 시험을 통해 유효성을 확인하였다.

시력 개선을 위한 Netspeg 렌즈의 임상적 검증 (The Clinical Examination of Netspeg Lens for Good Visual Acuity)

  • 김덕훈;배한용;김선태
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.281-291
    • /
    • 2006
  • 본 연구는 굴절이상을 가진 피검자의 시력 개선을 위한 Netspeg 렌즈의 임상적 검증을 하였다. 피검자는 성인 100명(남성 50인, 여성 50명; 평균 21세, 연령은 19세와 24세 사이)의 200개 눈을 대상으로 검사하였다. 피검자는 전신건강, 약물복용, 유전병, 알레르기, 전신질환 그리고 안질환을 포함하는 문진 등을 조사하였다. 굴절검사는 객관적인 방법을 사용해서 단안과 양안을 기록하였다. 시력측정은 양안에 Netspeg 렌즈와 CR-39를 착용하여 실시하였다. 입체시 검사는 Netspeg 렌즈와 CR-39를 착용해서 근거리에서 Titmus fly와 TNO를 사용해서 하였다. P-VEP 검사는 3채널의 16 pattern size(Bausch Lomb, production in U.S.A.)를 사용하였다. 피검자는 Netspeg 렌즈와 CR-39 렌즈를 사용하여 교정된 시력을 통해서 양안으로 patten 자극을 사용하였다. 역시 피검자는 Netspeg 렌즈와 CR-39 렌즈를 사용하여 교정된 시력을 통해서 양안시로 P-VEP 자극을 본다. 대비감도 검사는 대비감도 차트(Pelli-Robertson, made in USA)를 이용해서 1m 거리에서 Netspeg 렌즈와 CR-39를 장용해서 실시하였다. Netspeg 렌즈와 CR-39의 표면 미세구조는 SEM(JMS-5800, made in Japan)을 이용해서 관찰하였다. 연구의 결과는 다음과 같다. 1. Netspeg 렌즈와 CR-39를 사용한 비정상 굴절 피검자의 교정된 시력에서 Netspeg 렌즈를 착용한 피검자는 시각의 주관적 테스트에서 CR-39 착용자에 비해서 좋은 시야와 깨끗한 시력을 얻었다. 그러나 시력의 편안함은 Netspeg 렌즈와 CR-39는 비슷한 결과를 가졌다. 역시 Netspeg 렌즈 착용자의 피검자는 CR-39보다 좋은 시력을 가졌다. 한편 P-VEP 분석에서는 사용된 Netspeg 렌즈 착용자의 파의 진폭은 CR-39보다 더 증가한 모습을 가졌다(p>0.5). 또한 대비감도 검사에서 Netspeg 렌즈 착용자는 CR-39보다 좋은 결과를 가졌다. Netspeg 렌즈를 착용한 피검자의 TNO 입체시 검사 값은 그 결과가 CR-39보다 좋았다. 그러나 Titmus 입체시 검사에서는 Netspeg 렌즈와 CR 착용자는 비슷한 검사 결과를 나타내었다. 특히 초경발수 Netspeg 렌즈와 비구면 Netspeg 렌즈는 시기능 테스트에서 다소 비슷한 결과를 가졌다. 2. Netspeg 렌즈 표면의 미세구조는 CR-39보다는 매끄럽고 섬세한 구조와 선을 가졌다. 역시 Netspeg 렌즈는 미세구조에서 섬세한 선상 구조를 가졌다. 결론적으로 이 연구의 결과는 사용된 Netspeg 렌즈의 표면 미세구조는 CR-39보다는 더욱 특수한 pinhole 디자인 구조를 나타내었다. 이 연구는 사용된 Netspeg 렌즈의 시각은 비정상 굴절 눈을 위한 교정된 시력에 CR-39보다 좋은 것을 나타낸다. 따라서 저자들은 Netspeg 렌즈의 미세구조와 선 구조는 좋은 시기능과 관계되었을 것으로 추측된다. 그러나 비구면 Netspeg 렌즈와 초경발수 Netspeg 렌즈의 시기능에 대한 결과는 비슷하였다.

  • PDF

구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례 (Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report)

  • 양상현;김경아;김자영;서재민
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.207-214
    • /
    • 2015
  • 본 증례는 구순구개열 환자에서 상순의 반흔, 상악 잔존치조제의 과도한 흡수, 협소한 구개 및 상악골의 열성장을 동반한 3급 악간관계로 인해 통상의 가철성 국소의치 수복에 한계를 보이기 때문에 상악 무치악 부위에 4개의 임플란트를 식립 후, CAD/CAM 시스템으로 밀링한 titanium bar를 이용한 상악 가철성 임플란트 피개 국소의치를 계획하였다. 통상의 주조방법은 주조 후 수축을 하게 되지만 CAD/CAM 시스템으로 밀링한 titanium bar는 높은 정밀성과 경제성 그리고 가벼운 장점이 있다. 하지만 실제 임상에서 milled bar는 아주 균등하고 정확한 마찰결합을 얻기 힘들며 의치의 반복적인 착탈에 의해 마찰 유지력이 감소 할 수 있다. 이에 milled bar와 함께 사용할 수 있는 다양한 보조 유지장치(e.g. friction pin, $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ 등)를 같이 사용함으로써 부가적인 유지력, 경제성 및 교체의 용이성 등을 추가적으로 얻을 수 있다. 본 증례에서 milled titanium bar의 상부면에 drill and tapping 방법으로 $Locator^{(R)}$ 유지장치를 연결하였다. milled bar에 screw hole을 형성하고 3개의 $Locator^{(R)}$ 유지장치를 20 Ncm으로 체결하여 추가적인 유지력을 확보하였다. 보철수복 후, 환자가 원하는 심미적인 안모, 저작 기능 및 의치 유지에 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교 (Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean)

  • 이주령;안병철;정신영;이재태;이규보
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.120-127
    • /
    • 2003
  • 목적: 갑상선 절제술을 받은 분화 갑상선암 환자의 경우 잔여 갑상선 조직이나 전이 병소를 찾기 위해서는 진단적 I-131 스캔이 주로 사용되고 있으나, I-131 스캔은 갑상선 호르몬 중지가 필요하고, 방사성 옥소 투여후 $2{\sim}3$일에 영상을 얻어야 하며, 기절 현상이 발생할 수 있다는 점 등의 단점이 있다. 이에 비하여 Tc-99m 스캔은 검사가 용이하고 영상의 질이 좋아 진단적 I-131 스캔을 대체할 수 있을 지에 대한 논란이 있다. 이에 저자들은 고용량 방사성 옥소 치료 후 시행한 I-131 스캔을 기준으로 하여 치료전 시행한 Tc-99m 스캔의 진단성능을 알아보고자 하였다. 대상 및 방법: 갑상선 절제술을 받은 분화 갑상선암 환자 135명을 대상 (여: 114, 연령: $45{\pm}15.3$세)으로 하였고, 방사성옥소 치료 병력이 있는 환자는 23명 (1회 16명, 2회 4명, 3회 3명)이었다. 갑상선 호르몬 복용을 4주간 중단한 후 370 MBq의 Tc-99m pertechnetate를 정맥주사 한 20분 후에 전경부의 평면 및 바늘구멍 Tc-99m 스캔 영상을 얻었고, $3.7{\sim}7.4GBq$의 I-131 옥소를 경구 복용한 3일후 전경부 평면 및 바늘구멍 I-131 스캔 영상을 얻었다. Tc-99m 스캔과 I-131 스캔은 최대 7일 간격 이내에 시행되었다. 영상의 판독은 두명의 핵의학 전문의가 함께 합의에 의하여 시각적으로 섭취여부 및 섭취부위의 개수를 구하였다. 결과: 대상 환자 모두는 혈청 TSH는 30 mlU/L 이상으로, 갑상선 기능저하증 상태에 있었다. 전체 환자 135명 가운데 65명 (48.1%)에서 Tc-99m 스캔과 I-131 스캔이 불일치 소견을 보였다. 두 스캔사이에 불일치를 보인 환자 가운데 23명 (35.4%)은 Tc-99m 스캔에서는 전경부 방사능 섭취부위가 발견되지 않았으나 I-131 스캔에서 옥소 섭취부위가 발견된 경우이며, 42명 (64.6%)은 Tc-99m 스캔보다 I-131 스캔에서 전경부 옥소 섭취부위가 더 많이 발견되었다. 방사성 옥소 치료병력이 없는 환자 112명 가운데 51명 (45.5%)은 Tc-99m 스캔과 I-131 스캔이 불일치 소견을 보였다. 이들 가운데 Tc-99m 스캔에서 전경부 방사능 섭취부위가 발견되지 않았던 11명 가운데 9명 (81.8%)은 I-131 스캔에서 옥소 섭취부위가 발견되었다. 수술후 방사성옥소 치료를 받은 병력이 있는 전체 23명은 Tc-99m 스캔상 전경부 섭취부위가 발견되지 않았으나, 이들 중 14명 (60.9%)은 I-131 스캔에서 전경부의 옥소 섭취부위가 나타났었다. 결론: 이상의 결과로 보아 분화 갑상선암 환자의 수술 후 잔여 갑상선조직이나 전이병소를 평가시 Tc-99m 스캔은 고용량의 방사성 옥소 치료후 얻은 I-131 스캔을 기준으로 볼때 진단적 예민도가 낮았으며, 특히, 방사성 옥소 치료병력을 가진 환자의 경우, 진단적 유용성이 없는 것으로 생각된다.

파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측 (Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring)

  • 김영수;박진형;조화연;김재현;권흥록;서희;박세환;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 콤프턴 카메라는 검출 신호의 동시성 판단을 기반으로 한 전자적 집속방식을 이용하기 때문에, 기존의 물리적 집속기를 이용하는 감마선 영상 장비의 가시영역이 좁고 투과력이 높은 고에너지 감마선에 적용하기 어렵다는 한계를 극복할 수 있다. 특히 대면적의 콤프턴 카메라는 절대 검출 효율이 높아 영상 장비의 운반이 요구되지 않는 대규모 공정 시설내 핵물질의 모니터링용으로 매우 적합하다. 본 연구팀은 한국원자력연구원에서 개발 중인 파이로 시험 공정 시설에서의 안전조치 수립을 위해 대면적 콤프턴 카메라를 적용하고자 한다. 대면적 콤프턴 카메라를 구성하는 대면적의 검출기는 그 형태나 구성 방식에 따라 에너지 분해능이나 위치 분해능이 달라질 수 있다. 이는 콤프턴 영상의 질에 직접적으로 영향을 미치므로, 본 연구에서는 전산모사를 통해 그 영향을 예측하여 대면적 검출기의 설계 방향을 결정하였다. 또한 한국원자력연구원으로부터 파이로 시험 공정 시설의 정보를 전달받아 전산모사를 수행하였고, 여러 계측 환경에 대해 대면적 콤프턴 카메라의 성능을 예측하여 보았다. 그 결과 대면적 검출기는 에너지 분해능 측면에서의 손실을 최소화 할 수 있도록 구성하여야 한다는 결론을 얻었으며, 에너지 분해능 10%, 위치 분해능 7 mm 정도 성능의 검출기를 이용하여 콤프턴 카메라를 구성할 경우 1 m 거리에 위치한 감손우라늄 선원을 영상 해상도 16.3 cm(각도 분해능 $9.26^{\circ}$)으로 영상화할 수 있음을 확인하였다.