Abstract
Nickel plating thickness increased with the electric current density, and the augmentation was more thick in $6{\sim}10A/dm^2$ than low current. Hull-cell analysis was tested to evaluate the current density. Optimum thickness was obtained at a temperature of $60^{\circ}C$, and the pH fluctuation of 3.5~4.0. Over the Nickel ion concentration of 300 g/L, plating thickness increased with the current density. The rate of decrease in nickel ion concentration was increased with the current density. The quantity of plating electro-deposition was increased at the anode surface, which was correlated with the increase of plating thickness. The plating thickness was increased because of the quick plating speed. However, the condition of the plating surface becomes irregular and the minuteness of nickel plating layer was reduced with the plating rate. After the corrosion test of 25 h, it was resulted in that maintaining low electric current density is desirable for the excellent corrosion resistance in lustered nickel plating. According to the program simulation, the thickness of diffusion layer was increased and the concentration of anode surface was lowered for the higher current densities. The concentration profile showed the regular distribution at low electric current density. The field plating process was controlled by the electric current density and the plating thickness instead of plating time for the productivity. The surface physical property of plating structure or corrosion resistance was excellent in the case of low electric current density.
Keywords
nickel plating process; current density; Hull-cell test; concentration profile; corrosion resistance;
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Viktoria R. T. Hsu, J. Computational and Applied Mathematics, 183, 1 (2005)   DOI   ScienceOn
2 Y. Zhang, M. Liu, M. Wang, Q. Xie, and S. Yao, Sensors and Actuators B, 123, 444 (2007)   DOI   ScienceOn
3 B. S. Haran, B. N. Popov. G. Zheng, and R. E. White, J. Hazardous Materials, 55, 93 (1997)   DOI   ScienceOn
4 J. Lim, J. Whitcomb, J. Boyd, and J. Varghese, J. of Colloid and Interface Science, 305, 159 (2007)   DOI   ScienceOn
5 P. Schaetzel and B. Auclair, Electrochimica Acta, 43, 3375 (1998)   DOI   ScienceOn
6 L. K. BieniaszN, J. Electroanalytical Chem., 565, 273 (2004)   DOI   ScienceOn
7 C. Xu, M. Li, X. Zhang, K.-N. Tu, and Y. Xie, Electrochimica Acta, 52, 3901 (2007)   DOI   ScienceOn
8 G. Marshall, F. V. Molina, and A. Soba, Electrochimica Acta, 50, 3436 (2005)   DOI   ScienceOn
9 Gyorgy Pátzay, Reactive & Functional Polymer, 27, 83 (1995)   DOI   ScienceOn