• 제목/요약/키워드: pilotis structures

검색결과 14건 처리시간 0.027초

포항지진에 의한 필로티 건축물 피해조사 및 피해원인 분석 (Damage Investigation of Pilotis Structures and Analysis of Damage Causes by Pohang Earthquake)

  • 김주찬;신승훈;오상훈
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.3-10
    • /
    • 2019
  • On November 15, 2017, an earthquake($M_L5.4$) occurred in Pohang. Pohang earthquake was the second largest earthquake since earthquake was observed in Korea, but structural damage caused by earthquake was biggest. Structural damage caused by Pohang earthquake was mainly caused by schools and pilotis, above all damage to pilotis was outstanding. This is because area where pilotis structures are concentrated is located near epicenter, and seismic performance of pilotis structures is not excellent compared with general structures. In this study, described results of damage investigation and analysis of damage causes through analysis of pilotis Structures on 131 buildings that were investigated immediately after Pohang earthquake. In addition, cause of damage was analyzed through analysis of seismic wave. Investigation site was selected to Jangseong-dong, where damage occurred in large numbers. Damage level was classified into A, B, and C level by measuring residual crack width and story drift of structural members.

관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석 (Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis)

  • 유장열;김근호;채명진;김영문;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

바닥슬래브의 면내강성을 고려한 필로티 구조물의 효율적인 거동분석 (Efficient Analysis of Shear Wall Strustures with Pilotis considering the in-plane stiffness of the floor slabs)

  • 김현수;김혜숙;김현정;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.865-872
    • /
    • 2006
  • Recently, many apartment buildings in the shear wall system often has pilotis in the lower story to meet the architectural needs. If the lateral force resisting system consists of shear walls supported by columns and beams. the discontinuity at the lowest level with pilotis results in the vertical irregularity with strength and stiffness. So, there are needs to be considered tile analysis and design about column and beam bellow shear walls and the behavior and stress condition of structure by stiffness change being generated at shear walls. The purpose of this paper is to investigate the behavior of shear wall structures with pilotis using the floors modeled as rigid diaphragm or semi rigid diaphragm. Through analyses, after estimating values of the story drift, natural period, stress condition of shear walls and the forces of column, we inferred how the behavior of shear wall structures with pilotis was influenced by the floor stiffness.

  • PDF

필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로- (A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire-)

  • 황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.

Seismic characteristics of a Π-shaped 4-story RC structure with open ground floor

  • Karabini, Martha A.;Karabinis, Athanasios J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • 제22권4호
    • /
    • pp.345-353
    • /
    • 2022
  • The configuration of an open ground floor (pilotis) is a common and very critical irregularity observed in multistory reinforced concrete frame structures. The characteristics and the geometrical formation of the beams of the first story proved to be a critical parameter for the overall seismic behavior of this type of Reinforced Concrete (RC) structures. In this work the combination of open ground floor (pilotis) morphology with very strong perimetrical beams at the level of the first story is studied. The observation of the seismic damages and the in situ measurements of the fundamental period of four buildings with this morphology and Π-shaped plan view are presented herein. Further analytical results of a pilotis type Π-shaped RC structure are also included in the study. From the measurements and the analytical results yield that the open ground floor configuration greatly influences the fundamental period whereas this morphology in combination with strong beams can lead to severe local shear damages in the columns of the ground floor. The structural damage was limited in the columns of the ground floor and yet based on the changes of the in situ measured fundamental period the damaged level is assessed as DI=88%. Furthermore, due to the Π-shape of the plan view the tendency of the parts of the building to move independently strongly influences the distribution of the damages over the ground floor vertical elements.

필로티가 있는 전단벽의 효율적인 해석 (Efficient Analysis of Shear Wall with Piloti)

  • 김현수;이동근
    • 한국전산구조공학회논문집
    • /
    • 제16권4호
    • /
    • pp.387-399
    • /
    • 2003
  • 현재 국내에서는 벽과 바닥판으로만 이루어진 벽식구조형식이 아파트 건물에 많이 적용되고 있다. 이와 더불어 최근에는 건축 계획적인 필요에 따라서 필로티가 있는 건물이 급격히 늘어나고 있다 이런 건물은 전이보를 기준으로 상부층과 하부층의 구조적 특성의 급격한 변화가 발생하게 된다. 필로티가 있는 벽식건물을 정확하게 해석하기 위해서는 많은 수의 유한요소를 사용하여 구조물을 모형화하는 것이 필요하다. 그러나 구조물 전체를 수많은 요소로 세분하여 해석하는 것은 막대한 해석시간과 기억용량을 필요로 한다. 따라서 본 연구에서는 필로티가 있는 구조물에 효과적으로 적용할 수 있는 해석기법을 제시하고자 한다. 제안된 해석기법은 전이보를 슈퍼요소로 모형화하고, 각 부재 사이의 변형적합조건을 만족시키기 위하여 가상의 보를 사용하였다. 필로티가 있는 여러 가지 유형의 예제 모델을 사용하여 제안된 해석기법의 정확성을 검증하였다.

필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력 스펙트럼 (Required Strength Spectrum of Low-Rise Reinforced Concrete Shear Wall Buildings with Pilotis)

  • 이강석;오재근
    • 한국지진공학회논문집
    • /
    • 제11권5호
    • /
    • pp.61-69
    • /
    • 2007
  • 본 연구의 목적은 하부층에 필로티 구조, 상부층에 전단벽식구조를 가진 저층 철근콘크리트 건물의 내진설계 및 내진성능 평가를 위한 기본적인 자료를 제공하는 것으로서, 비선형 지진응답해석을 실시하여 각 층의 내력과 연성율 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 검토하였다. 본 연구에서는 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 특성을 2질점계로 치환하였으며, 하부층인 필로티 구조는 휨파괴형으로 상부층인 전단벽식 구조는 전단파괴형 시스템으로 각각 모델링하였다. 또한 각층의 복원력 특성으로는 필로티 구조는 Degrading Trilinear Model(휨파괴형), 상부층은 Origin Oriented Model(전단파괴형)을 선정하였다. 상기 복원력 특성은 각 층의 보유내력에 의하여 변화를 하며, 지진응답해석용 입력지진파로는 8개의 피해지진의 가속도 성분을 선정하여 이들 가속도 성분의 최대가속도를 0.1g, 0.2g, 0.3g로 표준화 하였다. 각각 지진강도수준에 따라 지진 응답해석을 실시하여 하부층 필로티 구조와 상부층 전단벽식 구조의 내력비와 응답 연성율 사이의 상관관계를 파악하였다. 최종적으로 특정 연성율을 위한 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력을 산정하여 요구내력 스펙트럼(Required Strength Spectrum)을 제안하였다. 본 연구에서 제안한 요구내력스펙트럼은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성율 이내로 머물게 하는 하한내력의 범위를 파악할 수 있는 등, 연구결과는 필로티 구조를 가진 철근콘크리트 전단벽식 건물의 내진성능평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 사료된다.

복합구조물의 응답해석을 위한 해석모델설정에 관한 연구 (A Study on the Modeling of the Response Analysis of Hybrid Structures)

  • 노희일;윤명호;권기혁;이춘호;서정원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.273-278
    • /
    • 2000
  • These days, the number of residential-commercial buildings and apartments with pilotis is increasing. Generally, these buildings have a special structural called as Hybrid Structures consisting of upper-Walls and lower-Frames. However, this structures have some problems to be solved for the application of the regulation on the earthquake-resistant design and analysis techniques. Especially, in the case of irregular formal structures, engineers have to consider both the equivalent static analysis and the dynamic analysis. Thus, it is recommended to analyze those to inelastic region for economical reasons. In this paper, the method of modeling preceding the inelastic dynamic analysis using the DRAIN-2DX is presented to compare with those from MIDAS GENw program.

  • PDF

4차산업혁명 건설IT융합기술기반 내진성능향상을 위한 Bridge System CFT 개발 및 드론을 이용한 건축물 성능검토 (4th Industrial Revolution Construction IT Convergence Technology Based Bridge System CFT for Seismic Performance Improvement and Performance Evaluation of Buildings Using Drones)

  • 김대건;장유경;문원규;이다솔;박수빈;이동운
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2018
  • Unlike the projects that the government has implemented recently to develop new cities under the New Deal project, Saeddeul Village projects to improve the environment of the city are gaining attention. The problem has been found to be that many of the buildings in Saeddeul Village are still not earthquake-proof by using drones to review the state of the town. It also revealed that after two years of earthquakes, Pilotis structures are the most vulnerable to earthquakes. However, it is suitable for small spaces in the city because it provides parking spaces as well as residential spaces. Accordingly, the focus should be on repair and reinforcement rather than reconstruction. In this study, a concrete-based seismic design and construction method is developed in the columns of the existing pylotis structure.

  • PDF