• Title/Summary/Keyword: pilot scale

Search Result 1,179, Processing Time 0.024 seconds

Oxidation of Organics Using a Direct Reaction of Peroxyl Radical and Ozone (페록시라디칼과 오존의 직접 반응을 이용한 유기물의 산화)

  • Choi, Seungpil;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.41-47
    • /
    • 2010
  • This study was conducted to assess the applicability of pilot scale system and to evaluate the treatment efficiency on operational parameters such as humic acid concentration, initial pH and air flow rate on the ozone/peroxyl radical reaction system. The decolorization of ozone/peroxyl radical system was higher than that of only process. Removal efficiency of ozone/peroxyl radical system was generally increased with the increase of intial concentration of humic acid but decreased over the range of 30mg/L. Treatment efficiency of HA at acid pH was smaller compared to that of neutral or basic pH and increased with increasing the air flow rate from 1L/min to 3L/min. In pilot-scale test, average removal of TOC and $COD_{Cr}$ was about 70% and 60%, respectively and ozone/peroxyl radical reaction system was indicated a potential in water treatment application.

DeNOx Characteristics of Hybrid SNCR-SCR Process in a Pilot Scale Flow Reactor (파일럿 규모 반응기에서 Hybrid SNCR-SCR 공정의 질소산화물 저감 특성)

  • Eom, Won-Hyun;Yoo, Kyung-Seun;Kim, Sung-June
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.89-94
    • /
    • 2011
  • DeNOx characteristics of hybrid SNCR-SCR process have been investigated in a pilot scale flow reactor. DeNOx efficiency of SNCR reaction was about 80% at $970^{\circ}C$ and hybrid SNCR-SCR process showed 92% at $940^{\circ}C$ with NSR = 2.0. Compared to SNCR process alone, hybrid SNCR-SCR process was more effective at cool side, which is lower than $940{^{\circ}C}$. It should be also noted that ammonia slip from hybrid SNCR-SCR process was below 1ppm at the condition of higher space velocity and the required catalyst volume can be decreased to 2/3 of SCR process. Key factors for DeNOx efficiency of hybrid SNCR-SCR process were found to be $NH_3$ concentration and NOx selectivity of urea injected in SNCR process.

Application of fluorescent particles as a tracer to detect the membrane surface damage in a pilot scale membrane bioreactor (형광입자를 이용한 분리막 표면 검측 방법의 파일럿 규모 플랜트 적용)

  • Kim, Choah;Kim, Hee Jun;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • In this study, a fluorescent silica nano particle is used as the surrogate for challenging test of membrane surface integrity. The particles are functionalized by a fluorescent dying agent so that as an ultraviolet light is imposed a bright fluorescent image from the particles can be taken. If a membrane surface is damaged and has a compromised part larger than the size of surrogate the fluorescent particles would pass through and contained in the permeate. An operator can directly notice whether the membrane surface is damaged or not by detecting a fluorescent image taken from the permeate. Additionally, the size of compromised part is estimated through analysing the fluorescent image in which we surmise the mass of particles included in the permeate by calculating an average RGB value of the image. The pilot scale experiments showed that this method could be applied successfully to determine if a membrane surface had a damaged parts regardless of the test condition. In the testing on the actual damaged area of $4.712mm^2$, the lowest error of estimating the damaged area was -1.32% with the surrogate concentration of 80 mg/L, flux of $40L/m^2/hr$ for 25 minutes of detection. A further study is still going on to increase the lowest detection limit and thus decrease the error of estimation.

The Comparison of Remediation Efficiency for Contaminated Soils under Vertical Drain System by Numerical Analysis Method (수치해석 방법에 의한 연직배수시스템의 오염토양 복원효율 비교분석)

  • Shin, Eun-Chul;Lee, Sung-Chul;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2011
  • The remediation efficiency of the contaminant through laboratory experiment of the pilot scale was evaluated for the influence factors in the contaminated soils for the applicability of the prefabricated vertical drain system. It was performed numerical analysis by the method that the finite element and finite differences based on the drawn result about the remediation of contaminated soils. The parametric analysis for the applied parameter value was performed. In the pilot scale remediation experiment, as a result of evaluating with the minimum limit concentration ratio, in the case of dense and loose conditon, the remediation time was much longer. And the remediation efficiency was rapidly progressed as the time was elapsed. It was analyzed that the contaminant concentration is reduced around the extraction well as the contamination remediating rate by numerical analysis result as the time was elapsed.

A Pilot Clinical Study of the Efficacy and Safety of Phellinus Linteus (Sanghuang) Extract Treatment for Knee Osteoarthritis

  • Ryu, Hwa yeon;Lee, Hyun;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.39 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • Background: To evaluate the efficacy and safety of Phellinus linteus (PL) extract for the treatment of knee osteoarthritis (KOA) a pilot clinical study was performed. Methods: There were 24 patients with KOA who enrolled in this double-blind, randomized, controlled, clinical trial. There were 3 groups: PL 1,000 mg/day (PL 1,000), PL 1,500 mg/day (PL 1,500), and dextrin 3,000 mg/day (placebo). Patients took capsules twice a day, 3 capsules at a time, over 8 weeks. Patients were monitored prior to treatment (Visit 1: Week 0), and followed up every 4 weeks (Visit 2: Week 4 and Visit 3: Week 8) where outcome measurements were taken. The primary outcome measure was the score from the Korean version of the Western Ontario and McMasters Universities from baseline to Week 8. The secondary outcomes were measurements from the visual analog scale, quality of life scale, erythrocyte sedimentation, and c-reactive protein. Adverse events were recorded at every visit. Results: The Korean version of the Western Ontario and McMasters Universities score showed the greatest improvement in symptoms of KOA in the PL 1,500 group compared with the placebo group. The erythrocyte sedimentation tended to decrease in the PL 1,500 group compared with the placebo group (which was within the normal range). The visual analog scale score decreased in all groups, with no significant differences between groups. No adverse events related to PL were reported. There were no abnormal hematological or physical findings. Conclusion: This pilot clinical trial was the first step to assess the efficacy and safety of PL used in the treatment of patients with KOA.

Development and Psychometric Evaluation of a Quality of Life Scale for Korean Patients with Cancer(C-QOL) (한국 암 특이형 삶의 질 측정도구(C-QOL) 개발 및 평가)

  • Lee, Eun-Hyun
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.3
    • /
    • pp.324-333
    • /
    • 2007
  • Purpose: The purpose of this study was to develop and evaluate a quality of life scale for Korean patients with cancer (C-QOL). Methods: The C-QOL was developed and validated as follows, item generation, pilot study, and psychometric tests. A total of 337 patients diagnosed with stomach, liver, lung, colon, breast, or cervix cancer were recruited. The patients were asked to complete the preliminary questionnaire comprising the content-validated items, the SF-36, and the ECOG performance status. The obtained data was analyzed using descriptive statistics, factor analysis, multidimensional scaling (MDS), multitrait/multi-item matrix, ANOVA, t-test, and Cronbach's alpha. Results: Preliminarily twenty-six items were generated through content validity and a pilot study. Factor analysis and MDS extracted a total of 21 items with a 5-point Likert-type scale (C-QOL). The C-QOL included five subscales: physical status (6 items), emotional status (6 items), social function (3 items), concern status (2 items), and coping function (4 items). The C-QOL established content validity, construct validity, item convergent and discriminant validity, known-groups validity, reliability, and sensitivity. Conclusion: The Newly developed C-QOL is an easily applicable instrument which established psychometric properties and reflected Korean culture. It is recommended for further study to examine the responsiveness of the C-QOL using a longitudinal research design.

A Study on a Small-scale Wastewater Treatment System Using MBR and IPNR (MBR과 IPNR을 이용한 소규모 하수처리 시스템에 관한 연구)

  • Kim, Young-Hee;Jo, Eun-Young;Yeo, In-Seol;Park, Seung-Min;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • In the purpose of this study, we investigate the characteristics of the pilot-scale wastewater treatment system applied to BAF, MBR and IPNR as examining the removal efficiency of organic pollutants and operating factors in small decentralized wastewater treatment systems, and operating factors. For long-term operation period of more than nine months, pilot-scale plant operating results appeared very stable. This results were the removal efficiency of BOD was 80.3% above and removal efficiency of COD with an average of about 91.0%, satisfied the final effluent water quality standards. TN in the final effluents was the average concentration of 7.9 mg/L, was satisfactory water quality standards 10 mg/L of TN.

The effect of backward walking training on balance, balance confidence and falls efficacy in patients with acute stroke: A pilot randomized controlled trial (후방 보행훈련이 급성기 뇌졸중 환자의 균형, 균형 자신감, 낙상 효능에 미치는 영향: 무작위 대조군 예비연구)

  • Jung, kyeoung-Man
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.2
    • /
    • pp.1-9
    • /
    • 2021
  • Background: The requirements for postural and motor control in backward walking training (BWT) may improve balance and walking speed in patients with acute stroke. The aim of this study was to analyze the effect of BWT on balance, balance confidence, and fall efficacy in this population. Design: Randomized controlled pilot trial. Methods: This study included 14 subjects with acute stroke (onset of illness less than one month). They were randomly allocated to a BWT (n=7) or forward walking training (n=7) group and observed five times in a week for a period of two weeks. Measurements were taken before and after the experiment using the Berg balance scale (BBS), Activities-specific balance confidence scale (ABC), and Fall efficacy scale (FES). Results: The BBS, ABC and FES scores obtained in both groups after the experiment were significantly higher than those before the experiment (p<0.05). In addition, the BBS, ABC, and FES scores in the experimental group were significantly higher than those in the control group (p<0.05). Conclusion: These findings indicate that BWT improved balance and balance confidence and decreased the risks of fall in patients with acute stroke. Further study is needed to better understand the effects of backward walking in acute stroke patients.

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

Pilot Study Analysis of Three Different Processes in Drinking Water Treatment

  • Kim, Dae-Ho;Lee, Byoung-Ho
    • Environmental Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, three pilot-scale plants with the capacity 30 $m^3$/day were designed and set up to treat reservoir water for the production of drinking water. Three treatment processes were compared in the pilot testing: process 1 (coagulation- flocculation- sedimentationsand filtration- ozone- BAC); process 2 (coagulation- flocculation- sedimentation- microfiltration-ozone- BAC); and process 3 (coagulation- flocculation- sedimentation- sand filtration- GAC). The quality of water has been evaluated on the basis of selected parameters such as turbidity, color, consumption of $KMnO_4$, dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), geosmin and 2-MIB. A detailed assessment of performance was carried out during a five months operation. Process 2 was found to have better removal efficiency of DOC, THMFP, geosmin and 2-MIB than process 1 and process 3 under identical conditions, although the removal rate of color was found to be the same in the three cases.