• Title/Summary/Keyword: pilot plant

Search Result 715, Processing Time 0.024 seconds

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

Advanced water treatment in pilot scale BAC-sand filter (Pilot Scale 생물활성탄 여과공정을 이용한 상수의 고도처리)

  • 이윤진;문철훈;김재우;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.47-52
    • /
    • 2002
  • This study was carried out to examine the characteristics of dual media filter with BAC and sand on a pilot scale which was installed in T Water Treatment Plant of Seoul. The conclusions drawn from experimental results are as follows : For the BAC-Sand filter, the preceded gravity sand filter did not largely affect the removal of organics and turbidity causing matters, tut the frequency of backwashing was explicitly reduced to two times with the stable growth of microorganisms. The biomass on media in case of existence of preceded sand filter was 1.4 times higher than that of nonexistence. In case of backwashing with water, the time needed to comply with below 10NTU took 22, 10, and 5 minutes respectively with the expansion ration of 1.2, 1.5 and 1.8. The higher the expansion ration was, the shorter the backwashing time was.

Thickening Characteristics of Residual from a Ceramic Membrane Water Treatment Plant (세라믹 막 정수공정에서 발생하는 배출수의 농축특성)

  • Bae, Byung-Uk;Shen, Xing-Hai
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.764-767
    • /
    • 2009
  • For a more effectively designed gravity thickener, thickening experiments were conducted for residuals produced by a ceramic membrane water treatment plant (WTP). Two kinds of residuals, one from backwashing (BW) and the other from chemically enhanced backwashing (CEB) procedure, were separately collected during a pilot plant experiment and their limiting solid flux ($SF_L$) measured. Batch thickening experiments showed that the BW and CEB residual had $SF_L$ of 10 and $25kg/m^2{\cdot}d$, respectively. Continuous operation of a pilot-scale gravity thickener proved that a mixed BW and CEB residual could be successfully thickened at the solid loading rate (SLR) of $12kg/m^2{\cdot}d$, allowing the concentration of the thickened residual to be about $15kg/m^2{\cdot}d$. From the experimental results and consideration of the seasonal thickening characteristics of the residual, SLR of $15kg/m^2{\cdot}d$ was proposed as a design parameter for full-scale gravity thickeners.

The Study on denitrification of low organic loading sewage by pre-denitrification process (유기물부하가 낮은 하수의 전달탈질공법에 의한 탈질방안)

  • Lee, Cheol Seung;Seo, Jong Hwan;Kim, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.779-878
    • /
    • 2004
  • This study was conducted to analyze the operating conditions of predenitrification process to improve the treatment efficiency in low organic loading sewage plant in use today, and to investigate the treatment efficiency of pilot plant added night soil as well as the nitrogen removal characteristics of pilot plant added carbon sources. In the operation under the condition of $BOD_{5}$ sludge load 0.03-0.28kg $BOD_{5}$/kg VSS/d and oxic ammoniac nitrogen sludge load 0.02-0.24 $kgNH_{4}^{+}$-N/kg MLVSS/d, nitrification efficiency is higher than 95%. In order to achieve 70% nitrogen removal at the T-N sludge loading 0.06kg T-N/kg VSSㆍd and the SRT 6~11 days, optimum operating factors were revealed to $CODc_{r}$/T-N ratio 9, recycle ratio 2.6, and denitrification volume ratio 0.33. At this time, denitrification capacity was approximately 0.09 kg $NO_{3}^{-}$-N/kg $CODc_{r}$; specific nitrification rate was 3.4mg $NH_{4}^{+}$-N/g MLVSS/hr; and specific denitrification rate was 4.8mg $NO_{3}^{-}$-N/g MLVSS/hr.

The design parameter evaluation of ion exchange process for ultra pure water production (초순수 생산을 위한 이온교환공정 설계특성 평가)

  • Park, Se-Chool;Kwon, Boung-Su;Lee, Kyung-Hyuk;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • In this study, cation and anion exchange process for performance evaluation was conducted. A pilot plant for the ultrpure water production was installed with the capacity of $25m^3/d$. The various production rate and regeneration of ion exchange rate were tested to investigate the design parameters. The test resulst was applied to calculate the operating costs. Changing the flow rate of the ion exchange capacity of the reproduction reviewed the cation exchange process as opposed to the design value is 120 to 164% efficiency, whereas both anion exchange process is 82 to 124% efficiency, respectively. This results can be applied for more large scale plant if the scale up parameters are consdiered. The ion exchange capacity of the application in accordance with the design value characteristic upon application equipment is expected to be needed. In this study, the performance of cation and anion exchange resin process was evaluated with pilot plant($25m^3/d$). The ion exchange capacity along with space velocity and regeneration volume was evaluated. In results, the operation results was compared with design parameters.

Treatment of Spent ion-Exchange Resins from NPP by Supercritical Water Oxidation(SCWO) Process (초임계수 산화공정에 의한 원전 폐수지 처리기술)

  • Kim, Kyeong-Sook;Son, Soon-Hwan;Song, Kyu-Min;Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.175-182
    • /
    • 2009
  • The spent cationic exchange resins and anionic exchange resins were separated from mixed spent exchange resins by a fluidized bed gravimetric separator. The separated resins were identified by an elemental analysis and thermogravimetric analysis. The each test sample was prepared by diluting the slurry made by wet ball milling the cationic exchange resins and the anionic exchange resins separated as a spherical granular form for 24 hours. The resulting test samples showed a slurry form of less than $75{\mu}m$ of particle size and 25,000ppm of $COD_{cr}$. The decomposition conditions of each test samples from a thermal power plant were obtained with a lab-scale(reactor volume : 220mL) supercritical water oxidation(SCWO) facility. Then pilot plant(reactor volume : 24 L) tests were performed with the test samples from a thermal power plant and a nuclear power plant successively. Based on the optimal decomposition conditions and the operation experiences by lab-scale facility and the pilot plant, a commercial plant(capacity : 150kg/h) can be installed in a nuclear power plant was designed.

  • PDF

Introduction to the first pilot plant project for geothermal power generation in Korea (국내 최초 지열발전 pilot plant 프로젝트 개요)

  • Yoon, Woon Sang;Lee, Tae Jong;Min, Ki-Bok;Kim, Kwang-Yeom;Jeon, Jongug;Cho, Yong-Hee;Song, Yoonho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.196.2-196.2
    • /
    • 2011
  • 지구온난화와 화석연료 고갈에 대한 우려로 전세계적으로 신재생에너지의 개발 및 활용이 본격화되고 있다. 특히, 다양한 신재생에너지원 중에서 날씨 및 계절에 의한 영향, 기저부하 담당, 지상 점유 면적, 소음 등 생활환경 영향, 경제성 등을 고려할 때 지열에너지는 미래 청정에너지원로서 기대와 관심이 집중되고 있다. 화산이 존재하지 않는 우리나라에서의 지열발전은 거의 불가능한 것으로 인식되어 지금까지의 심부 지열에너지 개발 프로젝트는 대부분 지역난방, 시설영농 등 직접이용을 목표로 추진되어 왔다. 그러나, 2003년부터 한국지질자원연구원에서 수행한 포항 심부지열에너지 개발사업의 결과로 얻어진 다양한 지질학적/지열학적 증거들을 토대로 분석한 결과, 국내 일부 지역에서는 지하 5 km 심도에서 최대 약 $180^{\circ}C$의 지온이 예상되어 국내에서도 심부 지열에너지를 이용한 지열발전에 대한 가능성이 제기되어 왔다. 여기에, 유럽과 미국 그리고 호주 등 선진국을 중심으로 비화산 지역에서 지하 심부에 인공적으로 지열저류층(파쇄대)을 생성하고 이를 통해 열매체(물)를 순환시킴으로써 생산된 증기를 발전에 활용하는 EGS (Enhanced Geothermal System) 기술이 개발되고 몇몇 성공사례가 발표되었다. 또한, 이러한 기술개발에 힘입어 EGS 지열발전에 대한 선진국의 과감한 연구비 투자가 이어졌다. 이러한 기술적 배경에 발맞추어 우리나라에서도 2010년 12월에 EGS 지열발전 과제가 착수되었다. 이 프로젝트는 아시아에서는 최초로 수행되는 EGS 기술 개발과제로서 2015년까지 약 480억원의 R&D 예산을 투입하여 MW급의 지열발전 pilot plant의 구축을 목표로 하고 있다. 프로젝트가 성공적으로 추진될 경우 국내외적인 파급효과는 매우 클것이다. 특히 2015년까지 1.5 MW의 pilot plant의 구축이 성공적으로 추진될 경우 국내에서는 2017년까지 3 MW 이상, 2020년까지 20 MW이상, 2030년까지 200 MW 이상의 지열발전이 가능할 것으로 기대된다. 또한 축적된 기술개발 경험을 바탕으로 인도네시아, 필리핀 등의 해외의 지열발전 사업에도 진출할 수 있는 계기가 될 것이다. 프로젝트는 넥스지오를 주관기관으로 하고 한국지질자원연구원, 한국건설기술연구원 및 서울대학교 등의 지질자원 관련 연구 및 교육기관과 포스코, 이노지오테크놀로지 등의 산업체가 참여하여 컨소시엄 형태로 추진하고 있으며, 향후 관심있는 여러 기관 및 산업체의 지원과 참여를 기대한다.

  • PDF

FASTMET$\circledR$ Process for Steel Mill Waste Recycling

  • Tanaka, Hidetoshi;Harada, Takao;Sugitatsu, Hiroshi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.387-392
    • /
    • 2001
  • Kobe Steel, LTD. and Midrex Technologies Inc. jointly developed the FASTMET$\circledR$ process as a steel mill waste recycle technology in which the DRI product meets BF feed material or BOF/EAF feed material requirements. FASTMET(R) process turns value-less wastes into valuable DRI and sellable zinc oxide, and gives the solution for the steel mill wastes recycling from both economical and environmental viewpoints. During the development of the process, Laboratory, Pilot Plant and Demonstration Plant tests were carried out from 1990 to 1998. The first FASTMET(R) commercial plant began operation in April, 2000 and the second commercial plant started in April, 2001 Both commercial plants have proceeded successfully preying that FASTMET$\circledR$ is a suitable process for recycling steel mill waste and for producing DRI as an iron source.

  • PDF

Separation of Iron and Nickel from Heavily Concentrated Aqueous Ferric Chloride Solution by Liquid-liquid Extraction (염화 제2철 농축 수용액으로부터의 액-액 추출에 의한 철과 니켈의 분리)

  • Park, Moo-Ryong;Kim, Young-Wook;Park, Jae-Ho;Park, Chin-Ho
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.274-280
    • /
    • 2007
  • A liquid-liquid solvent extraction process was developed in this study to recover Fe and Ni from heavily concentrated aqueous ferric chloride solution, in an effort to substitute the conventional iron reduction method. Solvent composition and extraction conditions were first developed from the laboratory experiments, and the pilot system was designed and built for commercialization. Stage numbers for extraction and stripping were determined from pilot plant runs, and other operation data were obtained for mass production.

  • PDF

A Pilot Study on Air Flotation Processes for Retrofitting of Conventional Wastewater Treatment Facilities (하수처리시설의 Retrofitting을 위한 파일럿 규모 공기부상공정 연구)

  • Park, Chanhyuk;Hong, Seok-Won;Lee, Sanghyup;Choi, Yong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.329-336
    • /
    • 2008
  • The pilot study was conducted to evaluate the applicability of air flotation(AF) processes combined with biological nutrient removal(BNR) for the retrofitting of conventional wastewater treatment facilities. The BNR system was operated in pre-denitrification and intermittent aeration; developed ceramic membrane diffusers were installed to separate the solid-liquid of activated sludge at the bottom of a flotation tank. Before performing a pilot scale study, the size distribution of microbubbles generated by silica or alumina-based ceramic membrane diffusers was tested to identify the ability of solid-liquid separation. According to the experimental results, the separation and thickening efficiency of the alumina-based ceramic membrane diffuser was higher than the silica-based ceramic membrane diffuser. In a $100m^3/d$ pilot plant, thickened and return sludge concentration was measured to be higher than 15,000mg SS/L, therefore, the MLSS in the bioreactor was maintained at over 3,000mg SS/L. The effluent quality of the AF-BNR process was 4.2mg/L, 3.7mg/L, 10.6mg/L and 1.6mg/L for $BOD_5$, SS, T-N and T-P, respectively. Lastly, it was revealed that the unit treatment cost by flotation process is lower than about $1won/m^3$ compared to a gravity sedimentation process.