• Title/Summary/Keyword: piezoresistive

Search Result 146, Processing Time 0.029 seconds

Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor (어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Kim, Jong-Yeol;Lee, Si-Woo;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

Measurement of Pressure Coefficient in Rotating Discharge Hole by Telemetric Method (무선계측기법을 이용한 회전 송출공의 압력계수 측정)

  • Ku, Nam-Hee;Kauh, Sang-Ken;Ha, Kyoung-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.9
    • /
    • pp.1248-1255
    • /
    • 2003
  • Pressure coefficient in a rotating discharge hole was measured to gain insight into the influence of rotation on the discharge characteristics of rotating discharge holes. Pressures inside the hole were measured by a telemetry system that had been developed by the authors. The telemetry system is characterized by the diversity of applicable sensor type. In the present study, the telemetry system was modified to measure static pressure using piezoresistive pressure sensors. The pressure sensor is affected by centrifugal force and change of orientation relative to the gravity. The orientation of sensor installation for minimum rotating effect and zero gravity effect was found out from the test. Pressure coefficients in a rotating discharge hole were measured in longitudinal direction as well as circumferential direction at various rotating speeds and three different pressure ratios. From the results, the behaviors of pressure coefficient that cannot be observed by a non-rotating setup were presented. It was also shown that the discharge characteristics of rotating discharge hole is much more influenced by the Rotation number irrespective of pressure ratio.

Fabrication of an acceleration sensor using silicon micromachining and reactive ion etching (실리콘 마이크로머시닝과 RIE를 이용한 가속도센서의 제조)

  • Kim, Dong-Jin;Kim, Woo-Jeong;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.430-436
    • /
    • 1997
  • A piezoresistive acceleration sensor for 30 G has been fabricated by silicon micromachining method using SDB(silicon direct bonding) wafer. The structure of the piezoresistive acceleration sensor consists of a seismic square pillar type mass and four beams. This structure was fabricated by reactive ion etching and chemical etching using KOH-etchant. The rectangular square structure is used in order to compensate the deformation of the edges due to underetching. The fabricated sensor showed a linear output voltage-acceleration characteristics and its sensitivity was about $88{\mu}V/V{\cdot}g$ from 0 to 10 G.

  • PDF

Development of High-Sensitivity Cantilever-Detected ESR Measurement Using a Fiber-Optic Interferometer

  • Tokuda, Yuki;Tsubokura, Daichi;Ohmichi, Eiji;Ohta, Hitoshi
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.173-177
    • /
    • 2013
  • Cantilever-detected high-frequency electron spin resonance (ESR) is a powerful method of sub-terahertz and terahertz ESR spectroscopy for a tiny magnetic sample at low temperature. In this technique, a small magnetization change associated with ESR transition is detected as deflection of a sample-mounted cantilever. So far, we have succeeded in ESR detection at 370 GHz using a commercial piezoresistive microcantilever. The spin sensitivity was estimated to ${\sim}10^{12}$ spins/gauss. In order to further increase the sensitivity, we adopt a fiber-optic-based detection system using a Fabry-Perot interferometer in place of piezoresistive system. Fabry-Perot cavity is formed between an optical-fiber end and microcantilever surface, and a change in the interference signal, corresponding to the cantilever deflection, is sensitively detected. This system is suitable for low-temperature and high-magnetic-field experiments because of its compact setup and less heat dissipation. In this study, performance of Fabry-Perot interferometer is evaluated, and its application to cantilever-detected ESR measurement is described.

The Etching Characteristics of TMAH/AP for the Diaphragm Fabrication of Pressure Sensors (압력센서용 다이아프램 제작을 위한 TMAH/AP 식각특성)

  • 윤의중;김좌연
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.4
    • /
    • pp.19-22
    • /
    • 2003
  • In this paper, Si anisotropic etching characteristics of tetramethylammonium hydroxide (TMAH)/ammonium persulfate (AP) solutions were investigated to realize the optimum structure of a diaphragm for the piezoresistive pressure sensor application. Due to its low toxicity and its high compatibility with the CMOS processing, TMAH was used as Si anisotropic etchants. The variations of Si etch rate on the etching temperature, TMAH concentration, and etching time were obtained. With increasing the etching temperature and decreasing TMAH concentrations, the Si etch rate is increased while a significant non-uniformity exists on the etched surface because of formation of hillocks on the <100> surface. With the addition of AP to TMAH solution, the Si etch rate is increased and an improvement in flatness on the etching front is observed. The Si etch rate is also maximized with increasing the number of addition of AP to TMAH solution per one hour. The Si square diaphragms of 20$\mu\textrm{m}$ thickness and 100-400 $\mu\textrm{m}$ one-side length were fabricated successfully by adding AP of (5/6)g to 800 ml TMAH solution every 10 minutes.

  • PDF

Fabrication and Characterization of a Pressure Sensor using a Pitch-based Carbon Fiber (탄소섬유를 이용한 압력센터 제작 및 특성평가)

  • Park, Chang-Sin;Lee, Dong-Weon;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.417-424
    • /
    • 2007
  • This paper reports fabrication and characterization of a pressure sensor using a pitch-based carbon fiber. Pitch-based carbon fibers have been shown to exhibit the piezoresistive effect, in which the electric resistance of the carbon fiber changes under mechanical deformation. The main structure of pressure sensors was built by performing backside etching on a SOI wafer and creating a suspended square membrane on the front side. An AC electric field which causes dielectrophoresis was used for the alignment and deposition of a carbon fiber across the microscale gap between two electrodes on the membrane. The fabricated pressure sensors were tested by applying static pressure to the membrane and measuring the resistance change of the carbon fiber. The resistance change of carbon fibers clearly shows linear response to the applied pressure and the calculated sensitivities of pressure sensors are $0.25{\sim}0.35 and 61.8 ${\Omega}/k{\Omega}{\cdot}bar$ for thicker and thinner membrane, respectively. All these observations demonstrated the possibilities of carbon fiber-based pressure sensors.

A Study on Pulse Wave Measurement System Based on USB Driver Transmission System (USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구)

  • Kim, E.G.;Park, M.K.;Han, S.S.;Huh, Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

Development of Integration Pressure Sensor Using Piezoresistive Effect of Chemical Vapor Deposition (CVD) Produced Multilayer Graphene (CVD공정으로 제작된 멀티레이어 그래핀의 압저항 효과를 이용한 직접화된 압력센서 개발)

  • Dae-Yun Lim;Tae Won Ha;Chil-Hyoung Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.470-474
    • /
    • 2023
  • In this study, a diaphragm-type pressure sensor was developed using multi-layer(four-layer) graphene produced at 1 nm thickness by thermally transferring single-layer graphene produced by chemical vapor deposition (CVD) to a 6" silicon wafer. By measuring the gauge factor, we investigated whether it was possible to produce a pressure sensor of consistent quality. As a result of the measurement, the pressure sensor using multilayer graphene showed linearity and had a gauge factor of about 17.5. The gauge factor of the multilayer graphene-based pressure sensor produced through this study is lower than that of doped silicon, but is more sensitive than a general metal sensor, showing that it can be sufficiently used as a commercialized sensor.

Comparison of the Characteristics of Metal Membrane Pressure Sensors Depending on the Shape of the Piezoresistive Patterns (금속 멤브레인 압력 센서에서 압저항체 패턴 형태에 따른 특성 비교)

  • Jun Park;Chang-Kyu Kim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2024
  • Development of pressure sensors for harsh environments with high pressure, humidity, and temperature is essential for many applications in the aerospace, marine, and automobile industries. However, existing materials such as polymers, adhesives, and semiconductors are not suitable for these conditions and require materials that are less sensitive to the external environment. This study proposed a pressure sensor that could withstand harsh environments and had high durability and precision. The sensor comprised a piezoresistor pattern and an insulating film directly formed on a stainless-steel membrane. To achieve the highest sensitivity, a pattern design method was proposed that considered the stress distribution in a circular membrane using finite element analysis. The manufacturing process involved depositing and etching a dielectric insulating film and metal piezoresistive material, resulting in a device with high linearity and slight hysteresis in the range of a maximum of 40 atm. The simplicity and effectiveness of this sensor render it a promising candidate for various applications in extreme environments.

Carbon strain sensor using Nd: YAG laser Direct Writing (Nd:YAG Laser 직접 각인을 이용한 Carbon 스트레인 센서)

  • Joo, Donghyun;Yoon, Sangwoo;Kim, Joohan;Park, Woo-Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • Nd:YAG laser was used to carbonize polyimide films to produce carbon films. This is a simple manufacturing process to fabricate low cost sensors. By applying this method, we studied characteristics of flexible and low-cost piezoresistive. Previously, many studies focused on carbonization of polyimide using $CO_2$ laser with wavelength of $10.6{\mu}m$. In this paper, carbonization (carbonization process) was performed on polyimide films using an Nd:YAG laser with a wavelength of $1.064{\mu}m$. In order to increase the resolution, we optimized the laser conditions of the power density ($W/cm^2$) and the beam scan rate. In previous studies using $CO_2$ laser, the minimum line width was $140{\sim}220{\mu}m$ but in this study, carbon line width was reduced to $35{\sim}40{\mu}m$. The initial sheet resistance of the carbon sensor was $100{\sim}300{\Omega}/{\square}$. The resistance decreased by 30% under stretched with a curvature radius of 21 R. The calculated gauge factor was 56.6. This work offers a simple, highly flexible, and low-cost process to fabricate piezoresistive sensors.