• 제목/요약/키워드: piezo

검색결과 712건 처리시간 0.024초

초음파 테이블을 이용한 단결정 사파이어 웨이퍼의 ELID 연삭가공 특성 연구 (A Study on the ELID Grinding Properties of Single Crystal Sapphire Wafer using Ultrasonic Table)

  • 황진하;곽태수;이득우;정명원;이상민
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.75-80
    • /
    • 2013
  • Single crystal sapphire being used in high technology industry is a brittle material with a high hardness and excellent physical properties. ELID(Electrolytic In-Process Dressing) grinding technology was applied to material removal machining process of single crystal sapphire wafer. Ultrasonic vibration which added to material using ultrasonic table was adopted to efficient ELID grinding of sapphire materials. The evaluation of the ground surface of single crystal sapphire wafer was carried out by means of surface measuring by using AFM(Atomic Force Microscope), surface roughness tester and optical microscope device. As the results of experiment, it was shown that more efficient grinding was conducted when using ultrasonic table. In case of using #170 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was superior to ELID ground specimen without ultrasonic table. However, In case of using #2000 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was inferior to ELID ground specimen without ultrasonic table.

박막형 압전재료 3203HD의 재료 비선형성을 고려한 바이모프 보 작동기의 비선형 유한 요소해석 (Finite element analysis of the PZT 3203HD bimorph beam actuator based on material non-linear characteristics)

  • 장성훈;김영성;이상기;박훈철;윤광준
    • 한국항공우주학회지
    • /
    • 제32권4호
    • /
    • pp.18-23
    • /
    • 2004
  • 본 논문에서는 고 전압, 고 응력 하에 있는 압전 재료의 재료 비선형 거동을 실험적으로 밝히고, 수치적으로 모사하였다. 응력 하에서, 압전 재료의 비선형 거동을 표현 할 수 있는 실험식을 압전 변형율에서 만들어 내었다. 그 식은 재료 비선형 해석을 위하여, 증분 형태의 유한요소 식에 적용되었다. 압전 상수에 대한 새로운 정의와 증분 형태로 표현된 압전 변형율이 보다 나은 비선형 거동의 복원을 위하여 유한 요소 정식화과정에 적용되었다. 이것으로, 높은 전기장 영역에서도, 박판형 압전 재료의 비선형 거동을 정확하게 복원하였다. 일련의 수행된 실험과 연구 과정의 검증을 위하여, 압전재료 바이모프 보 작동기가 수치적으로와 실험적으로 사용되었다. 재료 비선형 유한요소해석으로 예측된 변위와 실험으로 구해진 변위가 잘 일치함을 확인하였다.

압전필름센서를 이용한 복합재 샌드위치 보의 저속충격 모니터링 (Low Velocity Impact Monitoring for a Composite Sandwich Beam Using Piezo Thin Film Sensors)

  • 박찬익;이관호;김인걸;이영신
    • 한국항공우주학회지
    • /
    • 제31권2호
    • /
    • pp.51-56
    • /
    • 2003
  • 압전필름센서는 우수한 동적 감지 특성을 갖고 있어 복합재 구조의 저속충격을 모니터링하는데 유용하게 사용될 수 있다. 복합재 샌드위치 보에 대한 충격응답함수를 유도하였으며, 이를 충격시험와 비교하였따. 충격시험은 손상이 발생하지 않는 저에너지 조건에서 계측장치가 부착된 낙하식 충격시험기를 이용하여 수행하였다. 충격하중에 으한 샌드위치보의 거동을 예측하는 정방향 문제와 압전필름센서 신호로부터 충격력을 복원하는 역방향 문제에서 시험과 해석의 결과는 잘 일치하였다. 본 연구를 통하여 압전필름센서를 이용한 복합재 샌드위치 구조의 저속충격 모니터링 가능성을 확인하였다.

피에조 마이크로스트립 안테나의 주파수 이동에 관한 연구 (A Study on Frequency Shift of Piezo Microstrip Antennas)

  • 강현일;정연호;황현석;임윤식;유영식;송우창;이종성
    • 한국위성정보통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.22-25
    • /
    • 2012
  • 논문에서는 마이크로스트립 안테나 제작에 상용화되어 있는 에폭시계 FR-4 기판과 압전물질인 $LiNbO_3$와 PVDF를 기판으로 사용하여 마이크로스트립 패치 안테나를 제작하였다. 제작된 마이크로스트립 안테나에 DC 전계를 인가하였을 때 압전기판인 $LiNbO_3$와 PVDF의 경우 실시간으로 주파수 이동을 구현하여 안테나 제작 후에도 물리적 변형을 가하지 않고 공진주파수와 대역폭을 이동 및 조정할 수 있는 단일형 마이크로스트립 패치 안테나를 제작하고 특성을 분석하였다. 압전 특성을 갖는 $LiNbO_3$, PVDF 압전기판과 에폭시계 FR-4 기판을 사용하여 마이크로스트립 패치 안테나를 제작한 후 DC 전계를 인가함으로써 공진주파수의 이동을 확인하였다. 실험을 통하여 PVDF 압전기판에 400V/mm까지 DC 전계를 인가하였을 경우 최대 각각 17 MHz의 변화 값을 보였고 $LiNbO_3$는 29 MHz의 변화를 보였지만 FR-4 기판에서는 아무런 변화가 없었다. 이러한 결과들로부터 압전기판을 사용한 마이크로스트립 안테나는 안테나 제작 후에도 물리적 변형을 가하지 않고 공진주파수와 대역폭을 이동 및 조정할 수 있는 특성을 이용하여 최근 이동통신 분야에 많이 쓰이고 있는 마이크로스트립 안테나에 응용 가능하리라 사료된다.

퍼지제어기를 이용한 로보트 액츄에이터용 초음파 모터의 온도 보상에 관한 연구 (The Study on the Temperature Compensation of Ultrasonic Motor for Robot Actuator Using Fuzzy Controller)

  • 차인수;유권종;백형래;김영동
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.165-172
    • /
    • 1998
  • USM의 전기 기계적인 변환은 USM의 고정자에 정렬된 PZT트랜듀서를 구동하기 위한 2-상 고주파 전력 변환부와 고정자와 회전자 사이에 마찰력을 변환하는 기계적인 트러로써 나눠지며 이러한 구조특성 때문에 온도에 의한 비선형 특성이 내포하게 된다. 초음파 모터의 외함의 온도가 +2$0^{\circ}C$~3$0^{\circ}C$에서는 정상적인 특성을 나타내지만 장시간의 운전에 의한 모터의 마찰열에 의해 온도증가는 구동주파수, 구동전류, 속도의 감소를 가져온다. 현재 사용되고 있는 초음파 모터는 온도에 대한 보상이 이뤄지지 않고 있다. 본 논문에서는 퍼지제어 기법을 통해 초음파 모터의 운전중 외함의 온도증가에 따른 속도 보상용 시스템을 제안한다.

Fracture 환자의 유형(무자극,무침습) 재활촉진을 위한 외부궤도형 초음파 다층치료기의 구현 (Embodiment of outside orbit type supersonic waves multi curer for Fracture patient's type (radish stimulation, radish invasion) rehalititation promotion)

  • 김휘영;최진영;박성준;김진영;박성준;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2165-2166
    • /
    • 2006
  • Estrangement hierarchical by bipolarization is deepened and time space that social welfare by graying corresponds great so. Specially, is real condition that indifference by patient's increase which is solitary life string is come to involve by social problem.Together, Jaetaek bone fracture patient's ratio is zooming. Domestic BT technology, medical treatment solution technology offer more important role than role assistance enemy of modern technology and utilize by creative technology can. Specially, if apply supersonic waves in bone fracture treatment, there is treatise data that can reduce bone fracture treatment period of bone that bone does not stick well about 40%. Supersonic waves operation frequency used on both end because do 1m Hz, 1.3mHz, supersonic waves origination that have 1.5mHz's Piezo-ceramic crystal tranducer material each 4 premature senilitys in this research, and outside diameter according to impedance and Phase d used Gakgak4mm, 5.4mm, Dukke0.5mm, transformer deuce of length 70mm. Manufactured, and investigated supersonic waves distribution chart by capacity 50m W. Supersonic waves used by diagnosis mainly but is seen to become convenient medical treatment mounting in bone fracture patient's treatment if supplement clinically.If supplement system furthermore, is going to apply to osteoporosis patient, and this research tried to design poetic theme width directly and study rain standardization special quality and approach basic form because do modelling.

  • PDF

나사잭 메커니즘을 이용한 비폭발식 분리장치 (Non-explosive separation device using screw jack mechanism)

  • 박현준;이민수;조재욱;김병규
    • 한국항공우주학회지
    • /
    • 제38권4호
    • /
    • pp.321-326
    • /
    • 2010
  • 본 논문에서는 나사잭의 메커니즘을 이용한 인공위성의 비폭발식 분리장치를 설계 및 제작하였다. 분리장치의 구동기로는 정격토크가 $1.7kgf{\cdot}cm$의 성능을 가진 회전형 피에조 모터를 사용하여 분리장치의 안정적인 작동이 이뤄지도록 하였다. 또한 인공위성의 분리장치로의 성능을 검증하기 위하여 반응속도 실험, 준정적 하중실험, 충격실험을 수행하였다. 실험을 수행한 결과, 반응속도는 약 1.172초로 측정되었고, 45kgf의 하중에서도 안정적으로 견딜 수 있음을 확인하였다. 최대 충격 가속도는 18G가 측정이 되었는데 이것은 폭발식 분리장치에 비해 매우 작은 값이다. 우리는 이러한 실험을 통하여 제안한 분리장치의 신뢰성을 확인하였으며, 인공위성 분리장치로써의 가능성을 제시하였다.

Gold functionalized-graphene oxide-reinforced acrylonitrile butadiene rubber nanocomposites for piezoresistive and piezoelectric applications

  • Mensah, Bismark;Kumar, Dinesh;Lee, Gi-Bbeum;Won, Joohye;Gupta, Kailash Chandra;Nah, Changwoon
    • Carbon letters
    • /
    • 제25권
    • /
    • pp.1-13
    • /
    • 2018
  • Gold functionalized graphene oxide (GOAu) nanoparticles were reinforced in acrylonitrile-butadiene rubbers (NBR) via solution and melt mixing methods. The synthesized NBR-GOAu nanocomposites have shown significant improvements in their rate of curing, mechanical strength, thermal stability and electrical properties. The homogeneous dispersion of GOAu nanoparticles in NBR has been considered responsible for the enhanced thermal conductivity, thermal stability, and mechanical properties of NBR nanocomposites. In addition, the NBR-GOAu nanocomposites were able to show a decreasing trend in their dielectric constant (${\varepsilon}^{\prime}$) and electrical resistance on straining within a range of 10-70%. The decreasing trend in ${\varepsilon}^{\prime}$ is attributed to the decrease in electrode and interfacial polarization on straining the nanocomposites. The decreasing trend in electrical resistance in the nanocomposites is likely due to the attachment of Au nanoparticles to the surface of GO sheets which act as electrical interconnects. The Au nanoparticles have been proposed to function as ball rollers in-between GO nanosheets to improve their sliding on each other and to improve contacts with neighboring GO nanosheets, especially on straining the nanocomposites. The NBR-GOAu nanocomposites have exhibited piezoelectric gauge factor (${GF_{\varepsilon}}^{\prime}$) of ~0.5, and piezo-resistive gauge factor ($GF_R$) of ~0.9 which clearly indicated that GOAu reinforced NBR nanocomposites are potentially useful in fabrication of structural, high temperature responsive, and stretchable strain-sensitive sensors.

Effect of Nb Doping on the Dielectric and Strain Properties of Lead-free 0.94(Bi1/2Na1/2)TiO3-0.06BaTiO3 Ceramics

  • Han, Hyoung-Su;Hong, In-Ki;Kong, Young-Min;Lee, Jae-Shin;Jo, Wook
    • 한국세라믹학회지
    • /
    • 제53권2호
    • /
    • pp.145-149
    • /
    • 2016
  • $(Bi_{1/2}Na_{1/2})_{0.94}Ba_{0.06}(Ti_{1-x}Nb_x)O_3$ (BNBTxNb) ceramics were investigated in terms of the crystal structure as well as the ferroelectric, dielectric, and piezoelectric properties. While little change was observed in the microstructure except for a slight decrease in the average grain size, a significant change was noticed in the temperature dependence of dielectric and piezoelectric properties. It was shown that the property changes are closely related to the downward shift in the position of the ferroelectric-to-relaxor transition temperature with increasing amount of Nb doping. A special emphasis is put on the fact that Nb doping is so effective at decreasing the ferroelectric-to-relaxor transition temperature that even at no more than 2 at.% Nb addition, the transition temperature was already brought down slightly below room temperature, resulting in the birth of a large strain at 0.46 %, equivalent to $S_{max}/E_{max}=767pm/V$.

미세전극 패터닝 기술을 이용한 바이오센서 패턴 구현 (Implementation of Biosensor Pattern Using Micro Patterning Technique)

  • 고정범;김형찬;양영진;김현범;양성욱;오승호;도양회;최경현
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.122-128
    • /
    • 2016
  • The Biosensor biosensor pattern was developed by via an EHD (electro-hydro-dynamics (EHD) patterning process that was performed under atmospheric pressure at room temperature in a single step. The drop diameter was smaller than nozzle diameter and applied high viscosity conductive ink was applied in the EHD patterning method to provide a clear advantage over the piezo and thermal inkjet printing techniques. The Biosensor's biosensor's micro electrode pattern was printed by via a continuous EHD patterning method using 3three- type types of control parameters parameter (input voltage, patterning speed, nozzle pressure). High viscosity (1000 cps) conductive ink with 75 wt% of silver nanoparticles was used for experimentation. The incremental result of impedance of biosensor impedance was measured between the antibody ($10ug{\mu}g/ml$) to spore (0.1 ng/ml, 10 ng/ml, and $1ug{\mu}g./ml$) reaction at frequency 493 MHz frequency.