• Title/Summary/Keyword: piers

Search Result 723, Processing Time 0.024 seconds

Applicability Evaluation on the Analytical Formulas of the Scour Depth Estimation in the Bight River (교량세굴심 산정을 위한 만곡부하천에서의 산정식 적용성 평가)

  • Park, Soo-Jin;Park, Jae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4845-4852
    • /
    • 2012
  • This research calculated the scour depth of bridge according to inflow and outflow changes of stream's flood discharge and curves by applying scour depth formula for piers and abutments, and by comparing and examining them, evaluated the applicability of scour depth formulas. Overall, if the angles of flood discharge and inflow and outflow increase, the deviation rate of scour depth in bight increased. Especially the deviation rate was 58% at the inflow and outflow angle of $105^{\circ}$ that the bridge plan for this geography need careful examination. Next, as a result of calculating the deviation rate of scour depth at the bight by scour depth formulas, in case of pier, Andru formula showed 58% deviation rate, Laursen formula showed 26% deviation rate, and CSU. formula showed 17% deviation rate. In the case of abutment, Froehlich formula shows 44% deviation rate that when applying above scour depth formulas, scour depth calculation considering repairable characteristics of bight is necessary. Finally, about inflow and outflow angles of $45^{\circ}{\sim}135^{\circ}$ that showed big deviation rate of scour depth, this research performed regression analysis of deviation rates of scour depth due to flood discharge to suggest the regression formula.

Dynamic Responses of Multi-Span Simply Supported Bridges under Bi-Directional Seismic Excitations (2방향 지진하중을 받는 다경간 단순교의 동적거동분석)

  • Lee, Sang-Woo;Kim, Sang-Hyo;Mha, Ho-Seong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.21-32
    • /
    • 2004
  • A Seismic analysis procedure of bi-directional brideg motions is developed by using mechanical bridge model. A three-dimensional mechanical model can consider major phenomena under bi-directional seismic excitations, such as nonlinear pier motion under biaxial bending, pounding and bearing damage due to the rotaion of the superstructure, etc. The analyses utilizing the uni-directional and the bi-directional bridge model for the 3-span simply supported bridge are then performed. The seismic responses in two cases are examined and compared by investigating the relative displacements of each superstructure to both ground and adjacent superstructures and the restoring forces of RC pier. The analysis using either the uni-directional model or bi-directional model is acceptable for estimating the displacement responses of a bridge, but the bi-directional analysis is found to give more conservative results for resisting forces of RC piers. To make general conclusions, therefore, the analysis using the bi-directional bridge model should be performed in evaluating the seismic safety of bridges.

Development of Performance Based Resistance Capacity Evaluation Method for RC Compression Member under Vehicle Impact Load (차량 충돌하중을 받는 RC 압축부재의 성능기반형 저항성능 평가방법 개발)

  • Kim, Jang-Ho Jay;Yi, Na-Hyun;Phan, Duc-Hung;Kim, Sung-Bae;Lee, Kang-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.535-546
    • /
    • 2010
  • Recently, the probability of collision accident between vehicles or vessels and infrastructures are increasing at alarming rate. Particularly, collision impact load can be detrimental to sub-structures such as piers and columns. The damaged pier from an impact load of a vehicle or a vessel can lead to member damages, which make the member more vulnerable to impact load due to other accidents which. In extreme case, may cause structural collapse. Therefore, in this study, the vehicle impact load on concrete compression member was considered to assess the quantitative design resistance capacity to improve, the existing design method and to setup the new damage assessment method. The case study was carried out using the LS-DYNA, an explicit finite element analysis program. The parameters for the case study were cross-section variation of pier, impact load angle, permanent axial load and axial load ratio, concrete strength, longitudinal and lateral rebar ratios, and slenderness ratio. Using the analysis results, the performance based resistance capacity evaluation method for impact load using satisfaction curve was developed using Bayesian probabilistic method, which can be applied to reinforced concrete column design for impact loads.

Comparison of Performance of Restrainers of Steel Cables and Shape Memory Alloy Bars for Multiple-Span-Simply-Supported Bridges (다경간 단순지지 교량의 강케이블 및 형상기억합금 변위제어장치의 성능 비교)

  • Choi, Eun Soo;Kim, Lee Hyeon;Park, Joo Nam;Cho, Hyo Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.587-597
    • /
    • 2007
  • Steel restrainer cables for multiple frame bridges in California in the United States have been shown to be effective in preventing unseating at internal hinges during the past several earthquakes. Consequently, the steel-cable-restrainer is being tested for applications on multiple-span-simply-supported (MSSS) bridges in the mid-American region. In addition, shape memory alloy (SMA) bars in tension are being studied for the same application, multiple frame bridges, the developed seismic forces are transferred to piers through the restrainers. However, in MSSS bridges, the seismic forces are transferred to abutments by the restrainers. Therefore, the abutment' behavior should also be investigated. In this study, we assessed the seismic performance of the three types of restrainers, such as steel restrainer cables, SMA in tension, and SMA in bending for an MSSS bridge from moderate to strong ground motion, bending test of an SMA bar was conducted and its analytical model was determined for this study. Nonlinear time history analyses were conducted to assess the seismic responses of the as-built and the retrofitted bridges. All three types of restrainers reduced the hinge opening and the SMA in tension was the most effective of the three devices in preventing the unseating, all restrainers produced damage on the abutment from the pulling action of the MSSS bridge due to strong ground motions, was found that the retrofit of the abutment in the pulling action is required in the installation of restrainers in MSSS bridges.

GPR Survey for the Assessment of Scour Depth near Bridge Piers (세굴심 추정을 위한 교각 우물통 주변의 GPR 탐사)

  • Park, In-Chan;Cho, Won-Cheol;Lee, Chong-Guk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.996-1000
    • /
    • 2005
  • 본 연구에서는 마포대교 확장 공사의 인해 일부 교각의 우물통 기초 주변 하상변화와 세굴 현상을 파악하기 위한 심도추정 방법으로 현재 다양하게 토목분야에서 적용되고 있는 치하투과레이더 탐사기법을 사용하였다. 교각 우물통 주변의 안정적인 GPR 탐사를 수행하기 위한 보조장비를 고안하여 마포대교 P6의 우물통 주변을 2004년 6월(1차)과 2004년 10월(2차)에 걸쳐 탐사를 실시하였으며, 탐사 기간 중 약 12,000 cms의 유출량이 발생하여 국부세굴과 하상 변화 가능성을 충분히 검토 할 수 있을 것으로 판단되었다. 수집된 자료를 통해 양질의 자료 획득을 위해서 자료의 보정 과정을 마친 후 각각의 구간에 대해서 1, 2차 탐사된 두 개의 자료를 비교 분석하였다. 전구간의 반사파를 이용하여 기존의 연구결과에서 얻어진 반사파의 양상(Beres and Haeni, 1991)과 비교한 결과 하상 표면은 미사 혹은 실트로 구성되어 있고 주요한 하상 하부 매질은 전석(boulder), 호박돌 등으로 이루어져 있었다. 그리고 1차 및 2차 탐사 자료와 DATAPCS의 세굴센서가 설치된 측점을 기준으로 심도 및 위치 보정을 한 결과 큰 오차는 발생하지 않았으며, 400 MHz 안테나를 활용하여 최대수심 약 10 m 이상 하상을 탐사할 수 있었다. 수심이 깊은 구간은 하상과 가까운 위치에서 탐사를 실시하여 양질의 하상 변화 양상을 파악할 수 있어 하상 재료의 정성적인 평가를 높일 수 있도록 하였다. 마포대교의 탐사 대상 교각 우물통 주변은 계획홍수량의 1/3 수준으로 비교적 적은 홍수량이 발생한 2004년의 호우사상으로 인해 일부구간이 약 $10\~20\;cm$ 정도의 퇴적과 세굴 영향이 나타난 것을 제외하고는 유의할 만한 세굴과 하상 변화가 발생하지 않고 매우 안정적인 상태를 보이고 있으며 되메움이나 두드러진 퇴적층의 양상 또한 확인할 수 없었다. 대상구간에 설치한 유속계 최대유속이 2.0 m/s 이상 발생하였지만 우물통 주변의 자갈 및 호박돌 등과 같은 평균입경이 큰 유사의 이동에 절대적인 한계유속을 초과하지 못한 것으로 판단된다. GPR 탐사의 적용 한계성을 극복한 본 연구는 홍수 전$\cdot$후의 하상변화 및 최대세굴심, 되메움 깊이 및 범위 등의 세굴현상을 현장탐사를 바탕으로 현재 다양하게 적용하고 있는 세굴 실험식과 비교 분석함으로써 우물통 주변의 효율적인 세굴 보호 대책을 강구하는 목적으로 그 활용성을 증대할 수 있을 것이다.

  • PDF

Soil Modelling Method to Design Bent Foundation with Drilled Shaft Pier (단일 현장타설말뚝의 설계시 지반 모델링 방법)

  • Jeon, Kyung-Soo;Han, Kyoung-Bong;Song, Pil-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.368-376
    • /
    • 2010
  • The bent foundation with single drilled shafts is suitable and economical in South Korea, which has good rock in a shallow depth. This foundation has been designed with an elastic design concept. To apply a plastic design concept written in Korea Bridge Design Criteria, a detail design regulation, which includes the method for a plastic hinge point to occur above the ground, rebar arrangement and soil modelling, should be defined. Soil modelling should be considered in the respect of structural engineer's practicality. In this paper, single drilled shaft piers with 1m diameter are constructed, and cyclic lateral load tests loaded at 4m above the ground are taken to examine the behavior. Reduced diameter shaft above the ground and remaining the steel casing under the ground were used to induce plastic hinge to occur above the ground. Simplified soil models such as elastic relation and p-y curve are adapted, and the prediction results are compared with test results. Prediction results of a model bridge were compared according to soil models with time domain analyses, and design criteria of soil were proposed.

  • PDF

A Study on the Comparison and Analysis of Debris Reduction System on Small Bridge (소교량 유송잡물 저감시설의 비교 분석 연구)

  • Kim, Sung-Joong;Jung, Do-Joon;Kang, Joon-Gu;Yeo, Hong-Koo;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.31-41
    • /
    • 2016
  • Damage to structures, such as bridge piers, are increasing rapidly due to the debris moving along rivers at the time of flooding. Therefore, the debris fin, debris deflector and debris sweeper, which are debris reduction systems, were produced in this study and an accumulation experiment was carried out on the experimental channel according to the existence of the reduction system. The debris fin is the reduction system that creates parallel flow on debris accumulated on the bridge to pass through the bridge, which was produced using wood. In addition, the debris deflector was produced using steel pipes and it has the type of detouring the direction of debris. The debris sweeper passes the debris using the magnetic force rotation of a screw-shaped cylindrical structure by water flow and it was produced using acrylic material. The experiment was carried out by analyzing the level of accumulation according to the hardness and dropping method of the debris and comparing the accumulation rate of reduction systems, and the experiment was carried out 5 times. According to the experimental results, there was a difference in the accumulation rate according to the type of reduction system and the shape of debris, and it often depended significantly on the initial shape of debris accumulation. The direct debris reduction effect on the bridge was higher in the order of the debris deflector, debris sweeper and debris fin, but in case of the debris deflector, damage, such as stream turbulence, changes in water level and river bed, and the loss of deflector can occur due to debris accumulated directly on the debris deflector. Therefore, it is necessary to design the debris deflector considering these issues.

A Study to Improve the Operation Criteria by Size of Ship in Ulsan Tank Terminal (울산항 위험물 취급부두의 선박크기별 운용기준 개선방안에 관한 연구)

  • Kim, Seungyeon;Kim, Jongsung;Kim, Youngdu;Lee, Yunsok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.639-646
    • /
    • 2016
  • In order to establish an operational standard based on ship size, this study considered a specific safety management plan for Ulsan along with international standards, analyzed the results of mooring safety assessment at four vulnerable piers and suggests cargo stoppage and emergency unberthing standards as follows. In accordance with ship characteristics, ships of less than 10,000 tons are recommended to limit their activities for wind speeds of 18-21 m/s and wave heights of 1.0-1.5 m. Ships from 10,000-50,000 tons are recommended to observe wind speeds of 17-20 m/s and wave heights of 1.2-1.5 m, while, ships of 50,000-100,000 tons are recommended wind speeds of 15-19 m/s and wave heights of 1.5 m. Ships of more than 100,000 tons are recommended wind speeds of 14-18 m/s and wave heights of 1.5 m.

Experiments on the Composite Action of Steel Encased Composite Column (강재 매입형 합성기둥의 합성작용에 관한 실험)

  • Min Jin;Jung In-Keun;Shim Chang-Su;Chung Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.393-400
    • /
    • 2005
  • Steel encased composite columns have been used for buildings and piers of bridges. Since the column section for the pier is relatively larger than that of building columns, economical steel ratio needs to be investigated for the required performance. Composite action between concrete and embedded steel sections can be obtained by bond and friction. However, the behavior of the column depends on the load introduction mechanism. Compression can be applied to concrete section, steel section and composite section. In this paper, experiments on shear strength of the steel encased composite column were performed to study the effect of confinement by transverse reinforcements, mechanical interlock by holes, and shear connectors. Bond strength obtained from the tests showed considerably higher value than the design value. Confinement, mechanical interlock and stud connectors Increased the shear strength and these values can be used effectively to obtain composite action of Steel Reinforced Concrete(SRC) columns.

Assessment of Ecological Health of the Namcheon Stream using Epilithic Diatoms (부착규조를 이용한 남천의 하천 생태 건강도 평가)

  • Jeong, Ae-Suk;Jang, Seong-Hyun;Lee, Jung-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.6
    • /
    • pp.970-979
    • /
    • 2012
  • The purpose of study was to analyze the ecological health of the Namcheon Stream using Index of Biotic Integrity(IBI) Qualitative Habitate Evaluation Index(QHEI) and Water quality condition. Diatom samples were collected from ten sampling sites in the stream at total four times in 2006 and 2007. To assess ecological health of the stream, it was used modify metrics proposed by USEPA(1999). IBI values of the stream averaged 23 which was judged as a "fair". Physical habitate evaluation analysis showed that QHEI values in the stream averaged 57 indicating a "poor" condition. Water quality condition in the stream averaged "II" indicating a "a little good" condition In conclusion, ecological health of the Namcheon Stream was "fair" condition that means habitate minimally disturb in the aquatic environment and relatively good water quality. Especially, St. 6 St. 7, St. 8, and St. 9 showed that QHEI values in the stream averaged 47 indicating a "poor" condition. St. 6 exists mostly to interfere with the flow of the river piers and artificial beams around. They are also serious disturbance at riverbed structure in aquatic ecosystems. St. 10 was good about habitate condition however, it was disturbance of aquatic ecosystems due to nutrient. It is suggest that St. 10 needs to be managed for nutrient inflows.