• 제목/요약/키워드: physiological flow

검색결과 448건 처리시간 0.025초

협 부가 있는 동맥 내부에서의 맥동유동 (Pulsatile Flow in the Artery with Stenosis)

  • 손정락;주상우;서상호;심은보
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.39-44
    • /
    • 2002
  • The arterial stenosis related to the intimal thickening of the arterial wall is the main cause of many diseases in human cardiovascular system. Hemodynamic behavior of the blood flow is influenced by the presence of the arterial stenosis. In this study, effects of the pulsatile flow, caused by the periodic motion of the heart, on the blood flow and its interaction with the arterial stenosis are analyzed by the FEM-based computational fluid dynamics. As a result, it was found that the characteristics of the pulsatile flow in the artery with stenosis are quite different from those of the steady flow. And, the pulsatile flow condition affects the wall shear stress, which is one of the most important physiological parameters in the hemodynamics.

비강 내 공기유동에 대한 실험 및 전산유동가시화 (Numerical and experimental flow visualization on nasal air flow)

  • 김성균;박준형;휜광림
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.498-501
    • /
    • 2008
  • Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal, abnormal, and deformed nasal cavity models cavity models by PIV under both constant and periodic flow conditions. In this time normal and several deformed nasal cavity models, which simulate surgical operation, Turbinectomy, are investigated numerically by the FVM general purpose code and PIV analysis. The comparisons of these results are appreciated. Dense CT data and careful treatment of model surface under the ENT doctor's advice provide more sophisticated cavity models. The Davis (LaVision Co.) code is used for PIV flow analysis. Average and RMS distributions have been obtained for inspirational and expirational nasal airflows in the normal and deformed nasal cavities.

  • PDF

고혈압백서의 신장 Renin Heterogeneity에 관하여 (Heterogeneity of Renin Released from Renal Cortical Slices)

  • 전창렬;최병수;김선희;조경우
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.295-305
    • /
    • 1988
  • It has been well known that the renal cortical blood flow rate was much higher than that of the medulla and the renal blood flow distribution was affected by hemorrhage, volume expansion or salt-loading. The existance of the heterogeneities of glomerular filtration rate and nephron has also been reported. In order to understand the regulations and physiological roles of the heterogeneities, studies on the intrarenal renin-angiotensin system have been focused. Although it is well known that the granularity of iuxtaglomerular cells and renal renin content are more marked in superficial than in the deep glomeruli, their physiological significance is not quite clear. This study was therefore undertaken to clarify changes in renin response and isoelectric ronin profile to TMB-8 in outer, mid and inner cotices of normotensive and hypertensive rats. The basal rate of renin release was highest in outer cortex of Sprague-Dawley rat (SDR), Wistar rat (WR) and spontaneously hypertensive rat (SHR). The basal renin release from outer and inner cortex of SHR was significantly lower than that from those of SDR. The reponse of renin release to TM8-8 was highest in mid cortex and the increase of renin release in response to TMB-8 from inner cortex of SDR was significantly higher than that in SHR. In dehydrated rats, the basal renin release from renal cortical slices of SDR was increased but that from WR and SHR was not. The response of renin release to TMB-8 from mid and inner cortex of dehydrated WR tended to increase. In dehyrated SHR, increase of renin release from inner cortex was significantly higher than that in euhydrated SHR. No significant differences in the isoelectric renin profile were found both in different cortical areas and strains. In dehydrated rats, the percentage of renin form 2 was decreased and those of renin form 5 and 6 were increased. These results suggest that the heterogeneity of renin release from cortical area of euhydrated and dehydrated rats in response to TMB-8 may be related to the changes of renal blood flow and/or calcium metabolism in cortical area. These data also suggest that the renin forms with different isoelectric points may have an physiological significance.

  • PDF

흰쥐에서 고용량 아질산이온 함유 마늘 발효농축액에 의한 뇌혈류 변화 (Changes in Cerebral Blood flow Following Fermented Garlic Extract Solution with High Content of Nitrite)

  • 유혁;;구호;천현수;유수진;김민선
    • 동의생리병리학회지
    • /
    • 제34권6호
    • /
    • pp.326-333
    • /
    • 2020
  • Nitrate-nitrite-nitric oxide (NO) pathway is a major alternative source of NO and is essential for NO - dependent physiological functions in body. Food supplements having nitrate/nitrite can improve metabolic syndromes including hypertension through antioxidant activity or vasodilation. The purpose of this study was to observe the effects of fermented garlic (F. garlic) having high concentration of NO2- on changes in blood flow and nitric oxide synthesis in the cerebral cortex of rodents. The generation of nitric oxide detected by a chemi-luminescence detector was higher in F. Garlic compared with NaNO2 solution under artificial gastric juice with pH 2.0. Ether F. garlic or NaNO2 diluted with artificial cerebrospinal fluid was directly applied into around the needle probe of laser Doppler flow meter that was located on epidural surface of the cortex. Direct application of F. garlic resulted in increase of cerebral blood flow detected by a laser Doppler flow meter with a dose-dependent manner. Compared with NaNO2 solution, F. garlic produced changes in cerebral blood flow at lower concentration of NO2-. Pretreatment of methylene blue, a guanylyl cyclase inhibitor prevented upregulation of cerebral blood flow by the treatment of F. garlic. In addition, the application of F. garlic with 250, 500ppm of NO2- caused significantly the production of NO in the cortical tissue but NaNO2 solution with 500ppm of NO2- did not. In summary, these results suggested that F. garlic with high content of NO2- induce increase in cerebral blood flow through nitric oxide-dependent signal pathway.

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

전립선비대증 환자의 하부요로증상의 중증도에 따른 생리학적 지수 및 불안, 우울 (A Study on Physiological Index, Anxiety and Depression by the Severity of Lower Urinary Tract Symptoms in Patients with Benign Prostatic Hyperplasia)

  • 김중경;김진범;송민선
    • Journal of Korean Biological Nursing Science
    • /
    • 제18권3호
    • /
    • pp.127-134
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the physiological index, anxiety and depression by the severity of lower urinary tract symptoms in patients with benign prostatic hyperplasia. Methods: This research was conducted from the 4th to the 27th of May in 2016 on112 patients with benign prostatic hyperplasia. The data were analyzed using a chi-square test, ANOVA, and Pearson Correlation Coefficients. Results: The results demonstrated a difference depending on the dysuria period of each lower urinary tract symptom, marital status, occupation and perceived health state of the patient. The physiological index by lower urinary tract symptoms showed a difference in the maximum flow rate, amount of post-void residual urine and Prostate-Specific Antigen (PSA), and anxiety and depression factors also revealed a difference. Lower urinary tract symptoms showed a positive correlation to the amount of post voided residual urine and PSA, a negative correlation to the maximum flow rate and also indicated a positive correlation to depression. Conclusion: The results of the study belonging to the moderate and severe categories were high when the result was based on the categorization of subjects with benign prostatic hyperplasia with lower urinary tract symptoms. Considering that depression levels increase as the symptom intensifies and the anxiety score is also high with mild symptoms, psychological support intervention is needed when a pattern of benign prostatic hyperplasia appears.

비증환자(痺證患者) 58례(例)에 대(對)한 EAV측정치(測定値)의 진단적(診斷的) 고찰(考察) (Clinical diagnostic study of Physiological Signal data measured on 58 cases of numbness with EAV(Electro-puncture According to Voll))

  • 한상균;하치홍;조명래;유충열;이병열
    • Journal of Acupuncture Research
    • /
    • 제18권4호
    • /
    • pp.91-100
    • /
    • 2001
  • Background and Objective : Most diagnostic method for numbness were invasive and complex. So we need to simplify and objectify diagnostic method for numbness. Some study with EAV which is one of Physiological Signal Measuring Instruments, report significantly result as objective diagnostic method for other clinical symptom. By using EAV, we have obtained some physiological signal data from meridian-acupoints of 58 numbness cases. Objective and Methods : This study researched into the clinical statistics for 58 case who ware in numbness, and they ware treated with oriental medical care at the Dong-shin university oriental hospital during 1 year from April 3 2000 to March 30 2001. The data were analyzed and interpreted to compare with traditional differentiation of symptom-complexes, then further evaluated as the Five Evolutive Phases to make them differentiated. The EAV valus of Five Evolutive Phases were identified with the sequence of wood(木), fire(火), earth(土), steel(金), water(水). Results and Conclusion : These values of physiological signal were identical with standard differentiation of symptom-complexes of numbness which is the main cause of dishannonious flow of Qi and blood of the in the liver and deficiency of Qi and blood of the bladder with stagnancy of dampness. Among Five Evolutive Phases, Earth and wood values were increased, steel, fire and water were decreased significantly. This data imply the possibility of somewhat generalization from measuring instruments.

  • PDF

Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery

  • Hun Jung;Park, Jong-Wook;Park, Chan-Guk
    • Korea-Australia Rheology Journal
    • /
    • 제16권2호
    • /
    • pp.101-108
    • /
    • 2004
  • The hemodynamics behavior of the blood flow is influenced by the presence of the arterial stenosis. If the stenosis is present in an artery, normal blood flow is disturbed. In the present study, the characteristics of pulsatile flow in the blood vessel with stenosis are investigated by the finite volume method. For the validation of numerical model, the computation results are compared with the experimental ones of Ojha et al. in the case of 45% stenosis with a trapezoidal profile. Comparisons between the measured and the computed velocity profiles are favorable to our solutions. Finally, the effects of stenosis severity and wall shear stress are discussed in the present computational analysis. It can be seen, where the non-dimensional peak velocity is displayed for all the stenosis models at a given severity of stenosis, that it is exponentially increased. Although the stenosis and the boundary conditions are all symmetric, the asymmetric flow can be detected in the more than 57% stenosis. The instability by a three-dimensional symmetry-breaking leads to the asymmetric separation and the intense swirling motion downstream of the stenosis.

A critical review on blood flow in large arteries; relevance to blood rheology, viscosity models, and physiologic conditions

  • Yilmaz, Fuat;Gundogdu, Mehmet Yasar
    • Korea-Australia Rheology Journal
    • /
    • 제20권4호
    • /
    • pp.197-211
    • /
    • 2008
  • The purpose of this study is mainly directed towards present of viewpoints on critical and commentary analysis on blood rheology, blood viscosity models, and physiological flow conditions. Understanding these basics is fundamental to meet the need for a sufficient and reliable CFD model of blood. Most of the used viscosity models on this manner have determined from parameter fitting on experimental viscosity data. Availability of experimental data from literature to define viscosity models of CFD analysis should be accurately chosen and treated in order to avoid any errors. Several basic gaps that limit the CFD model results are identified and given opportunities for future research.