• Title/Summary/Keyword: physical experiment

Search Result 2,503, Processing Time 0.032 seconds

The Effect of a Thera-band Exercise Program on the Physical Function of Elderly Women (탄력밴드 운동프로그램이 여성노인의 신체기능에 미치는 효과)

  • Kim, Seok-Hwan;No, Jun-Hee
    • PNF and Movement
    • /
    • v.9 no.4
    • /
    • pp.1-11
    • /
    • 2011
  • Purpose : This study is to identify the effect of a thera-band exercise program on the physical function of elderly women. Methods : The subjects included 54 elderly women who participated in the program at J Senior Welfare Center in Jeollabuk-do. They were divided into two groups, 30 elderly women of control group and 24 of experimental group. A thera-band exercise program was conducted to both groups for total eight weeks-three times a week with a 50-minute period. After/before the experiment, the following seven categories were estimated for each subject: cardiopulmonary endurance, lower extremity power, upper extremity power, muscle endurance, flexibility, equilibrium, and agility. Results : There was a significant increase on the physical function of all the subjects in the experimental group and the control one after the experiment. Furthermore, the experimental group showed more meaningful improvement than the control one. Conclusion : On the basis of these findings, the thera-band exercise program contributes the enhancement of physical function of elderly women. Thus, more various physical exercise program should be developed for healthy aging.

Adverse Effect of the Methanotroph Methylocystis sp. M6 on the Non-Methylotroph Microbacterium sp. NM2

  • Jeong, So-Yeon;Cho, Kyung-Suk;Kim, Tae Gwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.10
    • /
    • pp.1706-1715
    • /
    • 2018
  • Several non-methylotrophic bacteria have been reported to improve the growth and activity of methanotrophs; however, their interactions remain to be elucidated. We investigated the interaction between Methylocystis sp. M6 and Microbacterium sp. NM2. A batch co-culture experiment showed that NM2 markedly increased the biomass and methane removal of M6. qPCR analysis revealed that NM2 enhanced both the growth and methane-monooxygenase gene expression of M6. A fed-batch experiment showed that co-culture was more efficient in removing methane than M6 alone (28.4 vs. $18.8{\mu}mol{\cdot}l^{-1}{\cdot}d^{-1}$), although the biomass levels were similar. A starvation experiment for 21 days showed that M6 population remained stable while NM2 population decreased by 66% in co-culture, but the results were opposite in pure cultures, indicating that M6 may cross-feed growth substrates from NM2. These results indicate that M6 apparently had no negative effect on NM2 when M6 actively proliferated with methane. Interestingly, a batch experiment involving a dialysis membrane indicates that physical proximity between NM2 and M6 is required for such biomass and methane removal enhancement. Collectively, the observed interaction is beneficial to the methanotroph but adversely affects the non-methylotroph; moreover, it requires physical proximity, suggesting a tight association between methanotrophs and non-methylotrophs in natural environments.

The Effect of Consistency between Represented Location of the Cue and the Target on Attention Mechanism (단서자극과 표적자극의 표상된 위치의 일치성이 주의기제의 작용에 미치는 영향)

  • Seo, Jun-Ho;Li, Hyung-Chul O.
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.4
    • /
    • pp.481-506
    • /
    • 2009
  • The purpose of the present research was to examine whether the attention mechanism employs physical or represented location of the cue and target. To achieve this, we have employed the paradigm of facilitation of response as well as inhibition of return. In the experiments, valid and invalid conditions were defined by the position consistency of the cue and the target in the aspect of either physical or represented location. We used auditory cue and visual target in Experiment 1 while visual cue and auditory target in Experiment 2. As a results, in Experiment 1, effect of facilitation of response in valid condition was found when the valid/invalid conditions were defined in the aspect of represented location. In Experiment 2, effect of facilitation of response in valid condition was found when the valid/invalid conditions were defined in the aspect of represented location. In all the other conditions, no effect was found when the conditions were defined in the aspect of physical location. No effects of inhibition of return were found in Experiment 2. These results imply the possibility that attention mechanism operates based on objects' represented location rather than on their physical location. More importantly, the present research suggests that it is necessary to separate represented location from physical location of the target and the cue in the experiment of facilitation of response and inhibition of return in the future.

  • PDF

Influencing of Electrical Stimulation to Cervicothoracic Sympathetic Ganglion on the Temperature Change of Body Surface (경흉교감신경절부의 전기자극의 체표면 체열변화에 미치는 영향)

  • Hwang Tae-Yeun;Park Rae-Joon;Kim Tae-Yul;Kim Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.121-132
    • /
    • 2000
  • This study was carried out to determine the influencing of electrical stimulation to cervicothoracic sympathetic ganglion(CTSG; stellate ganglion) u the sympathetic tone. For the purpose of this study. the stimulation was given to both the interferential current stimulation(ICS: AMF 100Hz) group consisting of 10 person(males 8, females 2) and the transcutaneous nerve electrical stimulation(TENS: 100 Hz) group of 10(males 7, females 3) in the right side of the trachea with probe electrodes. Then. the temperature changes on the surfaces of the forehead. cheek, neck and internal ear of cephalocervix, which is subject to the influence of the cervicothoracic sympathetic ganglion, and the palm. which is the end of the upper limbs. measured before. immediately alter. 10 minutes after and 20 minutes after experiment. The results are summarized as follows. 1. The emergence of remarkable Horner's symptoms which appear due to the changes of the tone of cervicothoracic sympathetic ganglion was not seen. However, in the interferential current stimulation group there were two felt the sense of warmth in the facial region and one person who felt it in the upper limbs, and in the transcutaneous nerve electrical stimulation group there was each one person who felt the sense of warmth in the facial region and in the upper limbs, respectively. Both groups have each one person who felt the sense of oppression in the eyelids. Three persons of the interferential current stimulation group and two persons of the transcutaneous nerve electrical stimulation group have the sense of hoarse voice or numbness in the neck. These are the symptoms that appeared during stimulation, so it is difficult for them to be considered as the direct effects of the changes of the tone of cervicothoracic sympathetic ganglion. 2. The t-test was performed to determine the significance between the right, which is the experimental side, and the left, which is the non-experimental side. Significance between the right, which is the experimental side, and the left, which is the non-experimental side. Significant changes were seen in the necks of the interferential current stimulation group and in the cheeks and internal ears of the transcutaneous nerve electrical stimulation immediately after experiment(P<.05). And the interferential current stimulation group showed a very high significance in the cheeks immediately after experiment and in the necks ten minutes after experiment(p<.01). Therefore, it could be seen that the electrical stimulation had an influencing on the changes of body temperature of the cephalocervix. 3. In both the interferential current stimulation group and the transcutaneous nerve electrical stimulation group, the forecheads, checks and necks of the cephalocervix in the experimental side(right) rather than the non-experimental side(left) had mostly a statistically significant rise in temperature immediately after experiment. The one-way ANOVA was carried out to determine the temperature change of on the surface of the body with the lapse of time; before, immediately after, ten minutes after and tewenty minutes after experiment. But no statistical significance was found from both the right and left sides.

  • PDF

Effects of Lumbar Stabilization Exercise on Lower Extremity Strength

  • Chung, Eun-Jung;Jang, Sang-Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.48-55
    • /
    • 2017
  • Purpose: this study was conducted on female university students in supine position and preformed the 2 bridge positions exercises, which are the bridge position exercise and the bridge exercise preformed with form rollers attached between their knees, in order to research the effects lumbar stabilization exercise has on lower extremity muscular strength. Method: In order for the participants to fully understand the topic and procedures of the experiment, they were given a 20 minutes of briefing and practice before the experiment. Result: Bridge exercise group and foam roller group were improved the knee flexion and extension strength. Conclusion: This research studied the difference of each lumbar stabilization positions and the effects they have on the fortification of the leg's flexion extension muscular strength, and by comparing which different exercise methods increase muscular strength the most works to plan a more optimal exercise method for lumbar stabilization.

The effects of Ultrasound on the Platelet of Rats (초음파가 생쥐의 혈소판에 미치는 영향)

  • Cho, Kwang-Ho;Park, Sang-Ock;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.139-149
    • /
    • 2001
  • We found out that there exists threshold dose for the decreased platelet count when we apply change of the platelet count to the defense of the ultrasound experiment. Those diminution is definite effects from the defense of the ultrasound. The number of the platelet count is decreased when we are exposed to ultrasound simultaneously. This should not be occurred. It is easy to use the number of the platelet count in the measurement of the biological dosage and intensity in high dosage relatively due to definite quantative relationship. The biological index to understand synergic effects. which are present when two harmful environmental factors are operating at the same time is functionally assending and antagonistic. There are scattered many factors as physical, Chemical, or physiochemically elements which are harmful to human body in the environment in consideration of ultrasound and the other factors. This experiment is demonstrating that we can use the change of the platelet as an index representing synergic effects of ultrasound.

  • PDF

Effect of Sling Exercise on Muscle Activity and Pain in Patients with Rotator Cuff Repair

  • Kim, Jae-Woon;Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.2
    • /
    • pp.45-49
    • /
    • 2017
  • Purpose: This study was conducted to determine the effects of sling exercise on muscle activity and pain in patients with rotator cuff repair. Methods: This research evaluated 20 rotator cuff repair patients, divided randomly between 10 controls and 10 in an experimental group who performed a sling exercise. Both the experimental and control groups underwent transcutaneous electrical nerve stimulation and performed continuous passive motion. Muscle activity was measured with a surface electromyograph and pain was measured with the visual analogue scale. The paired t-test was used to compare groups before and after the experiment. The independent t-test was conducted to assess differences in the degree of change between the two groups before and after the experiment. Results: Within-group comparison of both the experimental and control group showed significant differences in muscle activity and pain. Comparison of the groups revealed significant differences in muscle activity between groups group, but not in pain. Conclusion: These results indicate that sling exercise is effective for improving muscle activity of rotator cuff repair patients.

The Spatial Charateristics of Ventilation Efficiency (실내환기효율의 공간적 변화특성에 관한 연구)

  • 김신도;김태식;이희관;이정주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.236-241
    • /
    • 1993
  • Recently, with the ourdoor air pollution, the indoor air pollution devided into living environment and working environment are raised as the problem of indoor space. Also, the more time lived in indoor space, the larger the influence of indoor air pollution. Therefore in this study, the spatial variation of ventilation efficiency was estimated through the experiment using a physical model. The experiment using a physical model. The experiment was conducted in two category; the central zone of ventilated air flow and the corner zone. As the result of experiment, high ventilation efficiency (90$\sim$108%) was shown in the central zone of ventilated air flow. Whereas low ventilation efficiency (46$\sim$77%) was shown in the corner zone. In conclusion, when the designing of ventilation was planned, the zone showed low ventilation efficiency should be considered.

  • PDF

Measurement and Interpretation of Undergraduate Students' Writing about the Experiments of the Photoelectric Effect

  • Jho, Hunkoog;Ji, Youngrae
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1231-1239
    • /
    • 2018
  • This study aimed at examining undergraduate students' writing about experiments related to the photoelectric effect and giving some implications for experiment education. Thus, this study analyzed 26 students' reports about three kinds of experiments: measuring Planck's constant, comparing the photocurrent and the photovoltage across the intensity of light, and comparing the photocurrent and the photovoltage across the frequency of light. In the measurements, less than 25% of the students expressed the data to the correct number of significant figures even though two-thirds of the students successfully obtained the data given in the manual. In terms of interpretation, the students were not aware of the physical meanings of the detailed parts in the graphs. Even though over 50% of the students drew a line relating photocurrent to voltage, no students compared the theoretical to the empirical data or made a judgment as to whether of not the background theory really fit the experiment. The research findings showed that insufficient knowledge and skills for physics inquiry may be an obstacle in performing the experiments well.

Influence on Autonomic Function Before, During, and After Transcutaneous Electrical Nerve Stimulation in Senile Patients with Chronic Low Back Pain

  • Lee Mun-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.174-202
    • /
    • 2002
  • Twenty five patients, 14 males and 11 females with an average age of 75years with chronic Low Back Pain were tested before, during, and after 10minutes transcutaneous electrical nerve stimulation. It is important to consider the effect of TENS on the autonomic function because the pain pathway and the ANS pathway are somehow correlated to each other. There is still controversy among researchers who have reported the effect of TENS on autonomic function. So the purpose of this study is to measure the effect of TENS on the ANS and to see the relation of the pain control mechanism and the change in the ANS. The results were as follows : 1) Systolic blood pressure between before and during the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 2) Systolic blood pressure between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 3) Systolic blood pressure between before and after 10 minutes experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 4) Diastolic blood pressure between before and during experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 5) Diastolic blood pressure between during and after 10 minutes experiment was significantly decreased(P<.05). 6) Diastolic blood pressure between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 7) Heart rate between before and during the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05). 8) Heart rate between during and after 10 minutes the experiment was significantly decreased(P<.05). 9) Heart rate between before and after 10 minutes the experiment was significantly decreased(P<.05). 10) Skin temperature between before and during the experiment was significantly increased(P<.05). 11) Skin temperature between during and after 10 minutes the experiment was apt to be a little increased, but statistically there was no significant change(P>.05). 12) Skin temperature between before and after 10 minutes the experiment was significantly increased(P>.05). 13) Respiratory rate between before and during the experiment was apt to be a little increased, but statistically there was no significant change(Pgt;.05). 14) Respiratory rate between during and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(Pgt;.05). 15) Respiratory rate between before and after 10 minutes the experiment was apt to be a little decreased, but statistically there was no significant change(P>.05).

  • PDF