• Title/Summary/Keyword: physical conditions

Search Result 4,636, Processing Time 0.03 seconds

Effect of Contralateral Hip Adduction on Muscle Thicknesses of Lumbar Stabilizers and Pelvic Lateral Tilting During Hip Abduction in Side-lying (옆으로 누운 자세에서 고관절 외전시 반대 측 고관절 내전이 요추안정화 근육 두께와 골반 외측 경사에 미치는 영향)

  • Kim, Hyo-Uen;Choi, Bo-Ram;Kim, Su-Jung;Lee, Won-Hwee;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The purpose of this study was to determine the effect of contralateral hip adduction (CHA) on thickness of lumbar stabilizers during hip abduction in side-lying. Twenty healthy subjects without back pain were recruited for this study. The thickness of transverse abdominis (TrA), internal oblique (IO) and quadratus lumborum (QL) were measured by ultrasonography. Pelvic lateral tilting motion was measured using a three-dimensional motion analysis system. Measurements were performed at rest position (RP), $35^{\circ}$preferred hip abduction (PHA) and $35^{\circ}$abduction with $10^{\circ}$contralateral hip adduction (CHA) in side-lying at the end of expiration. During the measurements, subjects were asked to maintain steady trunk alignment without hand support. Thickness of TrA and IO was significantly greater in CHA than in PHA and RP conditions. There was no significant difference in thickness of TrA and IO between PHA and RP conditions. Medio-lateral (M-L) thickness of QL was not significant between PHA and CHA conditions. Anterio-posterior (A-P) thickness of QL in PHA and CHA significantly decreased compared to RP condition. Angle of pelvic lateral tilting was significantly decreased in CHA compared to PHA condition. In conclusion, CHA can be recommended for increasing trunk stability without compensatory pelvic motion during hip abduction exercise in side-lying.

Physiological Data Monitoring of Physical Exertion of Construction Workers Using Exoskeleton in Varied Temperatures

  • Ibrahim, Abdullahi;Okpala, Ifeanyi;Nnaji, Chukwuma
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1242-1242
    • /
    • 2022
  • Annually, several construction workers fall ill, are injured, or die due to heat-related exposure. The prevalence of work-related heat illness may rise and become an issue for workers operating in temperate climates, given the increase in frequency and intensity of heatwaves in the US. An increase in temperature negatively impacts physical exertion levels and mental state, thereby increasing the potential of accidents on the job site. To reduce the impact of heat stress on workers, it is critical to develop and implement measures for monitoring physical exertion levels and mental state in hot conditions. For this, limited studies have evaluated the utility of wearable biosensors in measuring physical exertion and mental workload in hot conditions. In addition, most studies focus solely on male participants, with little to no reference to female workers who may be exposed to greater heat stress risk. Therefore, this study aims to develop a process for objective and continuous assessment of worker physical exertion and mental workload using wearable biosensors. Physiological data were collected from eight (four male and four female) participants performing a simulated drilling task at 92oF and about 50% humidity level. After removing signal artifacts from the data using multiple filtering processes, the data was compared to a perceived muscle exertion scale and mental workload scale. Results indicate that biosensors' features can effectively detect the change in worker physical and mental state in hot conditions. Therefore, wearable biosensors provide a feasible and effective opportunity to continuously assess worker physical exertion and mental workload.

  • PDF

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Comparison of the effects of different-sized airways in inspiratory trainers on maximal inspiratory pressure and rating of perceived exertion scale in healthy young people

  • Hwang, Young-In;Kim, Ki-Song
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.1
    • /
    • pp.18-22
    • /
    • 2018
  • Objective: This study aimed to investigate the effect of different-sized airways of the inspiratory muscle trainer (IMT) on maximal inspiratory pressure (MIP) and the rating of perceived exertion, as measured by the modified Borg scale (m-Borg). Design: Cross-sectional study. Methods: Twenty healthy subjects (10 men, 10 women) volunteered for the study. The spirometry was used to measure MIP. The trial order of the three spirometry conditions was chosen randomly. After measuring the MIP and before taking the final break, each of the conditions were immediately measured using the m-Borg. All subjects used the IMT with an airway diameter of 5-, 6-, and 7-mm. Results: The MIP significantly decreased with the decreasing airway diameter of the IMT (p<0.001), and the differences in all three conditions (7- and 6-mm, 6- and 5-mm, and 7- and 5-mm airways) were significant (p<0.05). The RPE significantly increased with the decreasing airway diameter of the IMT (p<0.001), and the differences in all three conditions (7- and 6-mm, 6- and 5-mm, and 7- and 5-mm airways) were significant (p<0.05). Conclusions: Decreasing the airway diameter of the IMT decreased the MIP and increased the m-Borg. In regards to physical exercise within the clinical setting, the m-Borg could be a useful as a prior monitoring method to prevent dyspnea for patients with narrowed airways (blocked with secretion or sputum in pulmonary disease) and the different-sized airways of the IMT could be applied as a useful tool to improve MIP for prevention of pulmonary disease.

The Relationship Between Hip Adduction Angle of Ober Test According to Tibial Rotation and Length of the Iliotibial Band (정강뼈 돌림에 따른 오버테스트의 엉덩관절 모음 각도와 엉덩정강뼈 환 길이의 상관관계)

  • Park, Joo-Hee;Lee, Sa-Gyeom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.

Spatial Representation on the Part of Young Children according to Task Conditions (과제 제시방법에 따른 유아의 공간표상)

  • Min, Mi Hee;Yi, Soon Hyung
    • Korean Journal of Child Studies
    • /
    • v.33 no.5
    • /
    • pp.53-70
    • /
    • 2012
  • The purpose of this study was to investigate the effects of task conditions (physical similarity between the spatial product and the reference space, presentation place of the spatial product) on children's spatial representation. The participants consisted of 40 3-year-olds and 40 4-year-olds. The results of this study are as follows. Both 3-year-olds and 4-year-olds were capable of a greater degree of spatial representation when there was a high level of physical similarity between the spatial product and the reference space, and when the presentation place of the spatial product was in the reference space. 4-year-olds were capable of more accurate spatial representation than 3-year-olds. There was no significant difference in the children's spatial representation depending on the type of spatial product (scale model, map). The results revealed that the physical similarity between the spatial product and the reference space and the presentation place of the spatial product are essential in young children's spatial representation. Additionally, the results indicated that spatial representation of children develops gradually from when they are three to when they turn four.

The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory (계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정)

  • Derebew, Mulugeta;Kim, Min Seok;Park, Yon Kyu;Lee, Ho Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

Effects of Immobilization of the Ankle and Knee Joints on Postural Stability in Standing (바로 선 자세에서 발목과 무릎관절의 고정이 자세안정성에 미치는 영향)

  • Hwang, Su-Jin;Woo, Young-Keun;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.30-37
    • /
    • 2008
  • This study was designed to examine the effects of temporary immobilization of the ankle and knee joints on standing in healthy young adults with the use of a postural control mechanism. The subjects were twenty-four college students (12 males and 12 females, aged between 20 and 28). A Biodex balance system SD 950-302 and its software were used to measure indirect balance parameters in standing. Each subject underwent postural stability tests in 4-different joint conditions: free joints, ankle immobilization only, knee immobilization only, and ankle and knee immobilization. In addition, the postural stability test was conducted once with the subject's eyes open and once with the eyes closed conditions. For data analysis of the postural stability tests, the overall stability index, antero-posterior stability index, and medio-lateral stability index were recorded. The overall stability index (p=.000) and medial-lateral index (p=.003) were significantly greater different conditions with eyes closed in postural stability. Therefore, the eyes closed condition is expected to be used as an effective postural stability training for treatment planning in patients with unstable postures. In addition, training based on the dynamic multi-segment model can improve postural stability and is available to therapeutic programs, helping people with unstable balance to reduce their risk of falling.

  • PDF

The Comparision of the Static Balance, Contact Area, and Plantar Pressure of Flexible Flat Foot According to Elastic Taping

  • Hyeon-Seong Joo;Sam-Ho Park;Myung-Mo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.421-429
    • /
    • 2022
  • Objective: The purpose of this study was to compare and analyze the effects of arch support taping on static balance, static/dynamic foot contact area, and ground reaction force during walking according to the types of elastic tapes with mechanical elasticity differences. Design: Cross-sectional study Methods: Twenty-six participants selected for flexible flat feet through the navicular drop test were randomly assigned to non-taping, Dynamic-taping, and Mechano-taping conditions. Static balance and foot contact area were compared in the standing posture according to arch support taping conditions, and foot contact area and ground reaction force were compared during walking. Results: There was no significant difference in static balance according to the taping condition in the standing position, but the foot contact area in the Mechano-taping condition showed a significant decrease compared to the non-taping condition (p<0.05). The foot contact area during walking significantly decreased in the Dynamic-taping and Mechano-taping conditions (p<0.05), but there was no significant difference between the ground reaction force. Conclusions: Based on the results of this study, it was confirmed that among the types of elastic taping, arch support taping using dynamic taping and Mechano-taping has the effect of supporting the arch with high elastic recovery. Any type of elastic tape can be used for arch alignment in flexible flat foot.

Animals Physical Therapy (동물물리치료)

  • Nam Gun Wook;Kim Jin Ung
    • Journal of the korean veterinary medical association
    • /
    • v.39 no.5
    • /
    • pp.412-423
    • /
    • 2003
  • Physiotherapy may be defined as the use of physical techniques for the treatment of injuries and movement dysfunction. In the world of human medicine, physiotheraphy has been proven as an indispensable aid in the recovery of many muscloskeletal conditions

  • PDF