• 제목/요약/키워드: photographic measurement

검색결과 64건 처리시간 0.028초

피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 - (A Study on the Plan Photogrammetry for Clothing Design)

  • 박찬미;서미아
    • 복식문화연구
    • /
    • 제5권1호
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF

Measurement of Crystal Formation Using a Quartz Crystal Sensor

  • Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1659-1661
    • /
    • 2004
  • Measurement of supersaturation is important in crystallization processes, because it is one of key factors to control crystal size distribution and shape determining product quality. A monitoring system of the supersaturation using a quartz crystal sensor is applied to the supersaturation measurement. From the variation of resonant frequency, the beginning of the formation of salt crystal on the sensor surface is detected while the sensor is directly cooled down. The degree of supersaturation is computed from the solubility difference at the temperatures of the salt solution and the sensor. The performance of the propsed system of the supersaturation measurement is examined by applying the system to the crystallization of three different salt solutions. The experimental outcome compared with eye observation result and photographic analysis indicates that the proposed system is effective and useful to determine the supersaturation in the crystallization process. In addition, the microscopic monitoring of the initial stage crystallization is available with the sensor system.

  • PDF

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.

Measurement of Crystal Formation in Supersaturated Solution

  • Kim, Byung-Chul;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1196-1200
    • /
    • 2003
  • The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A monitoring system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The monitoring system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability.

  • PDF

3차원 변위측정을 위한 홀로스펙클 간섭법 (Holospeckle interferometry for measureen of 3-D displacement)

  • 박승옥
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.131-135
    • /
    • 1990
  • The combined technique of holographic interferometry and speckle photography, so called holospeckle interferometry, has been attention for the measurement of 3-D displacements. This new technique enables the researcher to obtain information of in plane and out-of plane displacements from one photographic plate. There is room for further development of special optical arrangement in order to apply holospeckle interferometry in specific field. In this study, the enlarged fringe pattern was obtained by specifical optical arrangement.

  • PDF

스캐너를 사용한 사진 이미지의 색측정 (Color measurement of photographic image using scanner)

  • 박진희;김홍석;박승옥
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.122-123
    • /
    • 2003
  • 색은 정보이다. 그러므로 다양한 매체를 통해 색을 정확하게 재현하기 위해서는 객관적인 색의 표시가 요구된다. 일반적으로 정확한 색표시를 위해서는 측색 기기를 사용해야 한다. 그러나 측색 기기는 가격이 비싸고 기기를 운용하는 전문적인 지식이 필요하다. 뿐만 아니라, 측정 면적의 한계로 이미지 속의 좁은 면적을 차지하는 색들은 측정이 불가능하다 본 연구는 널리 사용되고 있는 사무용 스캐너를 사용한 색측정 기술에 관한 것이다. (중략)

  • PDF

실시간 다색광전달함수의 측정 및 응용연구 (Real-time Measurement of Polychromatic Optical Transfer Function and Its Applications)

  • Song Jong Seop;Lee Yun U;Jo Jae Heung
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.26-27
    • /
    • 2003
  • A wide variety of devices and systems exist whose main function is to generate an image. These devices and systems are used for many different purposes and find applications in many different walks of life. We are all very familiar with some of these systems such as the photographic camera (that can produce a permanent record of a scene on sensitized sheet material) and the television set (that can receive a suitably coded electromagnetic signal broadcast through space and convert it into an image). (omitted)

  • PDF

차량 사고 분석에서 측정의 불확실성 (Uncertainty of Measurements in the Analysis of Vehicle Accidents)

  • 한인환;박승범
    • 대한교통학회지
    • /
    • 제28권3호
    • /
    • pp.119-130
    • /
    • 2010
  • 교통사고의 재구성 해석은 도로와 사고흔적, 자동차 손상 등 다양한 자료들을 분석함으로서 이루어진다. 대부분의 자료들은 사고 해석에서 변수로 작용하며, 측정으로부터 구해지는 자료들은 조사자와 도구, 주어진 환경 등에 의해 측정 오차가 발생된다. 따라서 사고해석에서는 측정 오차에서 비롯되는 불확실성이 항상 존재한다. 본 연구는 불확실성이 존재할 가능성이 매우 높은 도로 기하구조와 타이어 흔적 등 길이와 마찰계수 등에 대해 반복 측정 실험을 함으로서 교통 사고해석에서의 불확실성을 정량화하였다. 또한 자동차 충돌 변형량의 사진 계측에 대한 불확실성에 대해서도 해석 결과를 제시하였다. 이러한 통계학적 분포들은 사고 재구성 불확실성을 추정하기 위해 입력 계수의 적절한 범위를 결정하는 것을 도울 수 있다.

사진측정기의 동향 및 응용사례 (Current status and application of Photogrammetry)

  • 최정수;박응식;김형완;윤용식
    • 항공우주산업기술동향
    • /
    • 제6권2호
    • /
    • pp.80-89
    • /
    • 2008
  • 사진측정기는 2차원 사진 이미지를 사용해 비접촉식으로 3차원 좌표를 측정한다. 사진측정기는 2차원 사진으로부터 3차원 데이터를 재구성하기 위해 삼각측량법을 사용한다. 디지털 사진측정기는 측정사진에 대한 맵핑(mapping)과 비율 조정(scaling) 그리고 번들(bundle) 조정이 소프트웨어로 동시에 계산되며 이를 통해 카메라의 위치와 좌표를 해석해 낸다. 본 연구에서는 대형전파망원경의 구조적인 변형 측정, ISIM 시험 구조체의 사진측정기 결과 분석, 원자로 연료 조립물에 대한 수중 사진측정, 위성 광학 조립부 측정 및 위성 지상지원장비 측정과 같은 특별한 용도로 사용된 사진 측정기에 대해 소개하였다.

  • PDF

공급 질량비 변화에 따른 2유체 노즐의 액주분열특성에 관한 실험적 연구 (An Experimental Study on the Break-up Characteristics of Twin-Fluid Nozze According to tile Variations of Feeding Mass-ratio)

  • 강신재;오제하;노병준
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.63-75
    • /
    • 1996
  • The purpose of this study is to investigate the break-up characteristics by taking advantage of a two-phase coaxial nozzle. Air and water are utilized as working fluids and the mass ratio air/water has been controlled to characterize the atomization, diffusion and development of mixing process. By way of a photographic technique, conventional developing structures and diffusion angles have been analyzed systematically with variations of mass ratios. The turbulent flow components of the atomized particles were measured by a two channel LDV system and the data were treated by an on-lined measurement equipment. According to the photographic results the spreading angles decreased because the axial inertia moment was relatively higher than the lateral one with respect to the increase of mass ratio. It is found the jet flow diffuses linearly in a certain limit region while the atomizing characteristics, in terms of the distributions of particle diameters did not show particular differences. It may be expected that these fundamental results can be used as reference data in studying the atomization, breakup and diffusions.

  • PDF