• Title/Summary/Keyword: phenol wastewater

Search Result 123, Processing Time 0.023 seconds

Biodegradation of Phenol by Comamonas testosteroni DWB-1-8 Isolated from the Activated Sludge of Textile Wastewater (섬유 폐수 활성 슬러지에서 분리한 Comamonas testosteroni의 생물학적 페놀 분해)

  • Kwon, Hae Jun;Choi, Doo Ho;Kim, Mi Gyeong;Kim, Dong-Hyun;Kim, Young Guk;Yoon, Hyeokjun;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.156-161
    • /
    • 2020
  • Since industrialization, the production and utilization of various chemicals has contributed to improving the quality of our lives, but the subsequent discharge of massive waste is inevitable, and environmental pollution is becoming more serious every day. Exposure to chemicals as a result of environmental pollution is having a negative effect on human health and the ecosystem, and cleaning up the polluted environment that can affect our lives is a very important issue. Toxic aromatic compounds have been detected frequently in soil, groundwater, and wastewater because of the extensive use of oil products, and phenol, which is used to produce synthetic resins, textiles, and dyes, is one of the major pollutants, along with insecticides and preservatives. Phenol can cause dyspnea, headache, vomiting, mutation, and carcinogenesis. Phenol-degrading bacterium DWB-1-8 was isolated from the activated sludge of textile wastewater; this strain was identified as Comamonas testosteroni by 16S rRNA gene sequencing. The optimal culture conditions for the cell growth and degradation of phenol were 0.7% K2HPO4, 0.6% NaH2PO4, 0.1% NH4NO3, 0.015% MgSO4·7H2O, 0.001% FeSO4·7H2O, an initial pH of 7, and a temperature of 30℃. The strain was also able to grow by using other toxic compounds, such as benzene, toluene, or xylene (BTX), as the sole source of carbon.

Degradation of Cyanide by Activated Sludge Immobilized with Polyethylene Glycol (고정화 활성슬러지를 이용한 시안 분해)

  • Cheong, Kyung-Hoon;Choi, Hyung-Il;Kim, Jung-Ae;Moon, Ok-Ran;Kim, Myung-Hee
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1343-1351
    • /
    • 2008
  • The activated sludge obtained from wastewater coke oven plant was immobilized by entrapment with polyethylene glycol (PEG). The effects of several factors on the biodegradation of $CN^-$ from. synthetic wastewater were investigated using batch and continuous reactors. The degradation rate of $CN^-$ increased with increasing of the immobilized bead volume in the reactor. Approximately 7.65mg/L of $NH_4-N$ was produced upon the degradation of 35mg/L of $CN^-$. When high concentrations of the toxic cyanide complex were used in the testing of cyanide degradation, the free activated sludge could be inhibited more than that of the immobilized activated sludge. When the phenol concentration was higher than 400mg/L in the synthetic wastewater, approximately 98.4% of $CN^-$ was removed within 42 hours by the immobilized activated sludge. However, the cyanide was not completely degraded by the tree activated sludge. This indicates that high phenol concentrations can act as a toxic factor for the free activated sludge. A $CN^-$ concentration of less than 1mg/L was achieved by the immobilized sludge at the loading rate of 0.025kg $CN^-/m^3-d$. Moreover, it was found that the HRT should be kept for 48 hours in order to obtain stable treatment conditions.

Removal of Heavy Metal and Phenol from Aqueous Solution Using Fe(III) loaded Adsorbent (3가철 함유 흡착제를 이용한 수용액상의 중금속 및 페놀제거연구)

  • Kim, Seok-Jun;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu;Lee, Nam-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.541-548
    • /
    • 2009
  • Iron coated media (activated carbon, sand and starfish) were prepared at pH 4 and applied for the treatment of landfill leachate containing organic compounds and soluble metal ions such as $Zn^{2+},\;Cu^{2+},\;Mn^{2+}$ in batch and column experiment. The amount of iron coated in media was analyzed with EPA 3050B method. The removal efficiency of metal ions and phenol was compared with iron coated media. The amount of iron coated in Fe-AC and ICS(iron coated sand) were 1,612 mg/kg and 1,609 mg/kg, respectively, while it was higher with 1,768 mg/kg in ICSF(iron coated starfish). The result of batch study represent the highest removal efficiency in the treatment of wastewater using iron coated starfish. In column study, the removal efficiency of phenol and metal ions was higher in multi-layered system of ICS, Fe-AC and ICSF compared to single layered system. Breakthrough time in the effluent was relatively enhanced for $Cu^{2+}$ and $Zn^{2+}$ in multi-layered system while the removal efficiency of $Mn^{2+}$ were not varied much. Therefore, multi-layered system was identified as the better system for the treatment of wastewater containing of metal ions and organic compound.

Substrate Removal Characteristics for Low Temperature by Biological Activated Carbon (저온에서 생물활성탄의 기질제거특성)

  • Ryu, Seong Ho;Park, Chung Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.76-93
    • /
    • 1997
  • Activated carbon is widely used for the treatment of water, wastewater and other liquid wastes. Biological activated carbon (BAC) process is water and wastewater treatment process developed in the 1970's. In addition to activated carbon adsorption, biodegradation organic pollutants occurs in the BAC bed where a large amount of aerobic biomass grows. This results in a long operation time of the carbon before having to be regenerated and thus a low treatment cost. Although the BAC process has been widely used, its mechanisms have not been well understood, especially the relationship between biodegradation and carbon adsorption, whether these two reactions can promote each other or whether they just simultaneously exist in the BAC bed. Also, the phenomenon of bioregeneration has been confused that previously occupied adsorption sites appear to be made available through the actions of microorganisms. And that, because biological process is influenced by low temperature, the mechanism of the BAC process is also effected by temperature variation in our country of winter temperature near the freezing point. Therefore, the objective of this study examines closely the mechanism of the BAC process by temperature variation using phenol as substrate. From this study, biological activated carbon is good substrate removal better than non adsorbing materials (charcoal, sand) as temperature variation, especially low temperature(near $5^{\circ}C$).

  • PDF

Ni Nanoparticle Anchored on MWCNT as a Novel Electrochemical Sensor for Detection of Phenol

  • Wang, Yajing;Wang, Jiankang;Yao, Zhongping;Liu, Chenyu;Xie, Taiping;Deng, Qihuang;Jiang, Zhaohua
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850134.1-1850134.10
    • /
    • 2018
  • Increasing active sites and enhancing electric conductivity are critical factors to improve sensing performance toward phenol. Herein, Ni nanoparticle was successfully anchored on acidified multiwalled carbon nanotube (a-MWCNT) surface by electroless plating technique to avoid Ni nanoparticle agglomeration and guarantee high conductivity. The crystal structure, phase composition and surface morphology were characterized by XRD, SEM and TEM measurement. The as-prepared Ni/a-MWCNT nanohybrid was immobilized onto glassy carbon electrode (GCE) surface for constructing phenol sensor. The phenol sensing performance indicated that Ni/a-MWCNT/GCE exhibited an amazing detection performance with rapid response time of 4 s, a relatively wide detection range from 0.01 mM to 0.48 mM, a detection limit of $7.07{\mu}M$ and high sensitivity of $566.2{\mu}A\;mM^{-1}\;cm^{-2}$. The superior selectivity, reproducibility, stability and applicability in real sample of Ni/a-MWCNT/GCE endowed it with potential application in discharged wastewater.

Comparison of chemical properties of Co(II) and Cu(II) Compounds with Bis-Phenol A(Endocrine Disrupter)

  • Park, Chil-Nam
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.437-443
    • /
    • 2002
  • The chemical behavior and properties of the redox state of environmental pollutants were investigated using electrochemical methods. Cyclic voltammograms were performed on the compounds to measure the variations in the redox reactions. Temperature and pH were established as influencing the redox potential and current. The electrode reactions were a mixture of quasi-reversible and irreversible Precesses, which changed according to the reaction current. Although the Co(BPA)$_2$ and Cu(BPA)$_2$ compounds were not found to dissociate in wastewater, they were very unstable(K=1.02).

Simultaneous Removal of Phenol and Hexavalent Chromium by Rhodococcus sp. CP01 (Rhodococcus sp. CP01에 의한 페놀과 6가 크롬이온의 동시 제거)

  • 최광현;오영숙;김병동;최성찬
    • Korean Journal of Microbiology
    • /
    • v.36 no.4
    • /
    • pp.279-284
    • /
    • 2000
  • Simultaneous reduction of Cr(VI) and degradation of phenol was observed in batch and bench-scale continuous stirred tank reactors using Rhodococcus sp. CP01 isolated from leachate. The strain CP01, which was capable of utilizing phenol as a sole source of carbon and energy, completely reduced added hexavalent chromium (0.25 mM) to its trivalent form during 60 hr batch assay under optimal conditions (pH 7.0 and 1,000 mg/L of phenol concentration). The rates of Cr(VI) reduction and phenol degradation were estimated as 4.17 $\mu$M Cr(VI) and 38.4 mg phenol.$L^{-1}{\cdot}hr^{-1}$, respectively. The continuous culture experiment was conducted for 46 days using synthetic feed containing different levels of chromate (0.0625 to 0.25 mM) and phenol(1,000 to 4,000 mg/L). With a hydraulic retention time of 100 hr, Cr(VI) reduction efficiency was mostly 100% for influent Cr(VI) and phenol concentrations of 0.125 mM and 3,000 mg/L, respectively. During quasi-steady-state operation, specific rate of Cr(VI) reduction was calculated as 0.34 mg Cr(VI).g $protein^{-1}{\cdot}hr^{-1}$ which was comparable to reported values obtained by using glucose as growth substrate. The results suggest the potential application of biological treatment for detoxification of wastewater contaminated simultaneously with Cr(VI) and pheonol.

  • PDF

Determination of hazardous semi-volatile organic compounds in industrial wastewater using disk-type solid-phase extraction and GC-MS (디스크형 고상 추출법과 GC/MS를 이용한 공장폐수 중 반휘발성유기화합물질 분석)

  • Lee, In-Jung;Lim, Tae-Hyo;Heo, Seong-Nam;Nam, Su-Gyeong;Lee, Jae-Gwan;Cheon, Se-Uk
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.236-241
    • /
    • 2012
  • There are many industrial factories in the central Nakdong river basin and have been occurred water pollution accidents by hazardous chemicals such as phenol, 1,4-dioxane and perchlorate. In this study, ten compounds of semi-volatile organic compounds (SVOCs) (dichlorvos, toluene-2,4-diisocyanate, 4,4'-methylenedianiline, 4,4'-methylenebis (2-chloroaniline), diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthaltate, bis (2-ethylhexyl) adipate, benzophenone, 4,4'-bisphenol A) of hazardous chemicals which may be potentially discharged into the Nakdong river, were determined by gas chromatography-mass spectrometry (GC-MS) with disk-type solid-phase extraction. Accuracy and precision were in the range of 75.6~110.5%, and 4.6~12.7%, respectively and recovery was in the range of 72.4~127.9%. Three compounds (bis (2-ethylhexyl)adipate, benzophenone, 4,4'-bisphenol A) were detected in industrial wastewater such as wastewater treatment plants (WWTPs) and wastewater discharge facilities in the Nakdong River basin.

A Study on the Comparison and Analysis of COD Results and Experimental Methods (COD 측정분석 방법에 관한 연구)

  • 박선구;신찬기;류재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.19-29
    • /
    • 1997
  • The Chemical Oxygen Demand(COD) by potassium permanganate and potassium dichromate is used as a measure of the organic matter content of a sample. Newly proposed $K_{2}Cr_{2}O_{7}$ analysis method to be list at Korean Official Method was made from analysis and comparison of the experimental process on Japanese Industrial Standard(JIS), American Open Reflux and Closed Reflux Methods. New $K_{2}Cr_{2}O_{7}$ method had better the qualitative and reproducible COD results than another methods as a result of the tested four times repeatedly by using Lakes water Plant wastewater. The COD data ratio by $KMnO_{4}$ and $K_{2}Cr_{2}O_{7}$ methods was 2-3, 3, 2-17 and 3-4 times respectively when its data had compared with the lakes water and treated water of domestic and experimental wastewater, and raw wastewater which is generated at the manufacturing process of 6 steps and treated wastewater of chemistry source. Its ratio indicated to 2-4 and 2-3 times respectively on raw wastewater and plant wastewater of Chemistry, rubber and plastic, fiber, metal molding source. Oxidation ratio of benzene and ethyl benzene by $KMnO_{4}$ method was nearly zero, but the oxidation ratio by $K$_{2}Cr_{2}O_{7}$ method was 50%, 70% respectively. Also, Oxidation ratio of phenol by $KMnO_{4}$ and $K_{2}Cr_{2}O_{7}$ methods was 80%, 100% respectively, and trichloroethylene and tetrachloroethylene were not nearly oxidizd by $KMnO_{4}$ and $K_{2}Cr_{2}O_{7}$ methods. As the above contents, oxidation ratio and COD results by $KMnO_{4}$ and $K_{2}Cr_{2}O_{7}$ were different from various from various compounds and samples respectively.

  • PDF

A study on Anaerobic Biodegradation of Dichlorophenol (Dichlorophenol의 혐기성 분해에 관한 연구)

  • Park, Ju Seuk;Jeon, Yeon Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.127-135
    • /
    • 1995
  • The purpose of this study was to more fully evaluate the potential for chlorophenol degradation in anaerobic sludge. The pH effects on the ring cleavage of phenol and dechlorination of monochlorophenol isomers and dichlorophenl isomers. This study results are as follows ; Each of the monochlorophenol isomers were degraded in anaerobic sludge. The relatives rates were 2-Chlorophenol > 3-Chlorophenol > 4-Chlorophenol. Biodegradation results for the dichlorophenol isomers in anaerobic sludge are such as 2,3-dichlorophenol and 2,5-dichlorophenol was reductively dechlorinated to 3-chlorophenol, 2,4-dichlorophenol to 4-chlorophenol, 2,6-dichlorophenol to 2-chlorophenol. The two dichlorophenol isomers which did not contain an ortho Cl substituent 3,4-dichlorophenol and 3,5-dichlorophenol were persistent during the 6-week incubation. The rate of dechlorination was enhanced by the presence of a Cl group ortho, rather than para, to the site of dechlorination.

  • PDF